Introduction: Simulators facilitate the acquisition of technical skills for endoscopy. Here, we describe the development, introduction, and first evaluation of a novel generation of mechanical endoscopic retrograde cholangiopancreatography (ERCP) simulation models with simulated fluoroscopy, the X-Vision ERCP Training System.

Methods: A custom-made modular ERCP simulation system was built with the use of universally obtainable materials and tools. The trainee controls ERCP activities on two screens: the aspect of the papilla and duodenum is shown on the conventional endoscopy monitor, and the trainee’s actions in the equivalents of the pancreaticobiliary ducts are shown on the viewing screen of the model. Thereby, the latter screen serves as a substitute for fluoroscopy. Currently, four different models are available, allowing simulation of selective cannulation of the pancreatic or bile duct, intubation of differently arranged papillae, stent placement, and sphincterotomy of a biopapilla. The X-Vision ERCP Training System was first used during an ERCP course attended by 26 endoscopists. Trainees were supervised by an ERCP expert and an experienced ERCP nurse at each training model. The training system was evaluated by the participants and experts using a specific questionnaire.

Results: During the course there were no technical problems related to the X-Vision ERCP Training System. After sphincterotomy the organic papillae could easily be exchanged within less than 15 seconds. Overall, the X-Vision ERCP Training System achieved favorable results in all categories assessed.

Conclusion: The new X-Vision ERCP Training System is simple and effective. A first evaluation in the context of an ERCP course showed impressive results.

  • 1 Jowell P S, Baillie J, Branch M S. et al . Quantitative assessment of procedural competence. A prospective study of training in endoscopic retrograde cholangiopancreatography.  Ann Intern Med. 1996;  125 983-989
  • 2 Verma D, Gostout C J, Petersen B T. et al . Establishing a true assessment of endoscopic competence in ERCP during training and beyond: a single-operator learning curve for deep biliary cannulation in patients with native papillary anatomy.  Gastrointest Endosc. 2007;  65 394-400
  • 3 Neumann M, Mayer G, Ell C. et al . The Erlangen Endo-Trainer: life-like simulation for diagnostic and interventional endoscopic retrograde cholangiography.  Endoscopy. 2000;  32 906-910
  • 4 Gholson C F, Provenza J M, Silver R C, Bacon B R. Endoscopic retrograde cholangiography in the swine: a new model for endoscopic training and hepatobiliary research.  Gastrointest Endosc. 1990;  36 600-603
  • 5 Bar-Meir S. A new endoscopic simulator.  Endoscopy. 2000;  32 898-900
  • 6 Neumann M, Nietzschmann T, Hohenberger W. et al .[Erlanger Endo-Trainer - Neue Modellmodifikation für kamerassistiertes ERCP-Training.] http://Available at: www.endo-trainer/publication/ERC-1
  • 7 Leung J W, Lee J G, Rojany M. et al . Development of a novel ERCP mechanical simulator.  Gastrointest Endosc. 2007;  65 1056-1062
  • 8 Sedlack R, Petersen B, Binmoeller K, Kolars J. A direct comparison of ERCP teaching models.  Gastrointest Endosc. 2003;  57 886-890
  • 9 Bar-Meir S. A new endoscopic simulator.  Endoscopy. 2000;  32 898-900
  • 10 Baillie J. Endoscopic retrograde cholangiopancreatography simulation.  Gastrointest Endosc Clin N Am. 2006;  16 529-542
  • 11 Grund K E, Blank K, Storz B, Naruhn M. Integriertes didaktisches Kozept für die Endoskopie. Abstract. München; XXI. Kongreß der DGE-BV 1992 Mar: 26-28
  • 12 Hochberger J, Maiss J. Currently available simulators: ex vivo models.  Gastrointest Endosc Clin N Am. 2006;  16 435-449
  • 13 Gerson L B, Van Dam J. Technology review: the use of simulators for training in GI endoscopy.  Gastrointest Endosc. 2004;  60 992-1001

E. Frimberger, MD 

Technical University of Munich
Klinikum rechts der Isar
2nd Medical Department

Ismaninger Str. 22
81675 München
Germany

Fax: +49-89-41404871

Email: eckart.frimberger@lrz.tum.de

    >