Endoscopy 2008; 40: E79-E80
DOI: 10.1055/s-2007-995541
Unusual cases and technical notes

© Georg Thieme Verlag KG Stuttgart · New York

A novel technique for endoscopic reanastomosis in a patient with a completely strictured colorectal anastomosis

G.  Dafnis1
  • 1Colorectal Unit, Department of Surgery and Urology, Eskilstuna County Hospital, Eskilstuna, Sweden
Further Information

Publication History

Publication Date:
20 March 2008 (online)

Stricture, depending on its definition, is a complication in 0 %–30 % of colorectal anastomoses [1]. This article describes a novel technique for endoscopic reanastomosis in a completely strictured colorectal anastomosis with no visible lumen either at endoscopy or at radiography; to my knowledge this is the first publication of an entirely endoscopic technique.

In a 72-year-old man with carcinoma in the distal sigmoid, a stapled side-to-end colorectal anastomosis was performed and defunctioned with a loop ileostomy. Histopathology showed a moderately differentiated adenocarcinoma T3 N1 M0, which was considered microscopically radical.

An anastomotic dehiscence was detected at endoscopy 2 weeks postoperatively. Endoscopic lavage was initiated as an inpatient procedure for 2 weeks, then continued as an outpatient procedure for the following 3 months, thereafter pelvic computed tomography (CT) showed no abscess and the dehiscence was healed at endoscopy. At follow-up 6 months later, transanal water-soluble enema and water-soluble contrast through the efferent limb of the diverting loop ileostomy revealed no lumen at all in the anastomosis ([Fig. 1]). Endoscopy showed a completely intact mucosa and no lumen whatsoever to the proximal bowel ([Fig. 2]). Following intravenous analgesia (alfentanil) and sedation (midazolam), a gastroscope (Olympus GIF XTQ 160, Olympus Optical Co. Ltd., Tokyo, Japan) was used for transrectal puncture of the descending colon during fluoroscopic guidance with an Echotip-19® Ultra Endoscopic Ultrasound Needle (Cook Ireland Ltd, Limerick, Ireland) extended for 20 mm ([Fig. 3]). Water-soluble contrast was injected, thereby verifying the position of the needle in the descending colon ([Fig. 4]). A 450 cm long 0.035-inch guide wire (Jagwire, Boston Scientific Nordic AB, Helsingborg, Sweden) was inserted through the needle to reach the transverse colon ([Fig. 5]). A CRE™ Wireguided Balloon Dilator (Boston Scientific Nordic AB, Helsingborg, Sweden) was used to dilate the puncture hole to 15 mm (3 atm), a procedure lasting 10 minutes ([Fig. 6]), thus establishing an entirely endoscopically created colorectal anastomosis ([Fig. 7]). The GIF XTQ 160 could then pass through the newly created anastomosis without difficulty. The anastomosis was dilated again using a CRE™ Wireguided Balloon Dilator at 6, 9, and 20 weeks. Both ileostomy closure and follow-up 12 months later were uneventful.

Fig. 1 Radiograph showing no lumen at all in the anastomosis on transanal water-soluble enema.

Fig. 2 Endoscopic view showing some staples in the anastomotic area, a completely intact mucosa and no lumen whatsoever to the proximal bowel.

Fig. 3 Endoscopic view showing transrectal puncture of the descending colon using an Echotip-19 ® Ultra Endoscopic Ultrasound Needle.

Fig. 4 Radiograph showing the gastroscope, transrectal puncture of the descending colon, and injection of water-soluble contrast verifying the position of the needle in the descending colon.

Fig. 5 Radiograph showing the 450 cm long guide reaching the transverse colon. The colon is outlined with water-soluble contrast injected through transrectal puncture of the descending colon.

Fig. 6 Endoscopic view showing the Wireguided Balloon Dilator in place.

Fig. 7 Endoscopic view showing the newly created colorectal anastomosis.

Previous publications describe either different endoscopic techniques for cases where some lumen exists [2] [3] [4] [5] [6] or, in a case with no lumen, a combined endoscopic–transanal technique [7]. The difficulty with my technique is that the position of the needle tip, in the colon proximal to the strictured anastomosis, must be confirmed by fluoroscopy with absolute certainty before insertion of the guide wire and balloon dilation. The time to loop closure was due to logistic factors not related to the procedure. An earlier closure had avoided dilations at 9 and 20 weeks.

The technique is a minimally invasive, outpatient procedure, feasible for an experienced endoscopist, with limited procedure-related risk because the position of the needle is carefully checked by fluoroscopy before the guide wire is introduced. The whole procedure is performed over the guide wire, thus minimizing the risk of perforation. A redo anastomosis implies major surgery, an inpatient procedure, general anesthesia, laparotomy to remove the anastomosis and refashion a new anastomosis, and altogether much greater risk.

Endoscopy_UCTN_Code_TTT_1AQ_2AF

References

  • 1 Bannura G C, Cumsille M A, Barrera A E. et al . Predictive factors of stenosis after stapled colorectal anastomosis: prospective analysis of 179 consecutive patients.  World J Surg. 2004;  28 921-925
  • 2 Luck A, Chapuis P, Sinclair G. et al . Endoscopic laser stricturotomy and balloon dilatation for benign colorectal strictures.  ANZ J Surg. 2001;  71 594-597
  • 3 Suchan K L, Muldner A, Manegold B C. Endoscopic treatment of postoperative colorectal anastomotic strictures.  Surg Endosc. 2003;  17 1110-1113
  • 4 Piccinni G, Nacchiero M. Management of narrower anastomotic colonic strictures. Case report and proposal technique.  Surg Endosc. 2001;  15 1227
  • 5 Forshaw M J, Maphosa G, Sankararajah D. et al . Endoscopic alternatives in managing anastomotic strictures of the colon and rectum.  Tech Coloproctol. 2006;  10 21-27
  • 6 Anvari M. Endoscopic transanal rectal stricturoplasty.  Surg Laparosc Endosc. 1998;  8 193-196
  • 7 Reissman P, Nogueras J J, Wexner S D. Management of obliterating stricture after coloanal anastomosis.  Surg Endosc. 1997;  11 385-386

G. DafnisMD, PhD 

Colorectal Unit

Department of Surgery and Urology

Eskilstuna County Hospital

SE-631 88 Eskilstuna

Sweden

Fax: +46-150-51509

Email: george.dafnis@telia.com

    >