Endoscopy 2008; 40: E155-E156
DOI: 10.1055/s-2007-995326
Unusual cases and technical notes

© Georg Thieme Verlag KG Stuttgart · New York

Intestinal obstruction and bacteremia – complications of capsule endoscopy

G.  Dam1 , M.  J.  Nielsen1 , L.  A.  Christensen1
  • 1Aarhus University Hospital, Medical Department V, Denmark
Further Information

G. A. Dam, MD

PET-Centret

Aarhus Univeristy Hospital

Nørrebrogade 44

8000 Aarhus C

Denmark

Fax: +45-8949-3020

Email: gitte_dam@hotmail.com

Publication History

Publication Date:
30 July 2008 (online)

Table of Contents

Capsule endoscopy is a modality for the evaluation of small bowel mucosa and has a high diagnostic yield for evaluation of suspected small intestinal Crohn’s disease [1]. Capsule endoscopy is superior to barium follow-through in diagnosing patients with Crohn’s disease [2] [3]. The most serious complication of capsule endoscopy is mechanical obstruction caused by capsule impaction in a stricture. We present a case of mechanical ileus and bacteremia caused by impaction of the capsule in a patient with suspected Crohn’s disease, but with a normal barium follow-through prior to the endoscopy.

The patient was admitted to our hospital for capsule endoscopy due to weight loss, diarrhea, and abdominal pain. Prior to the procedure, a barium follow-through and ileocolonoscopy were carried out and revealed no abnormalities. The patient experienced abdominal pain and vomiting 5 hours after capsule ingestion. Abdominal radiograph was normal. The following day, temperature reached 41.5°C and a radiograph showed small intestinal obstruction ([Fig. 1]). Capsule endoscopy revealed ulcerations and stenosis compatible with Crohn’s disease (Fig. [2] [3] [4] [5]). The patient was treated with intravenous antibiotics and prednisolone. Abdominal radiograph was normal 2 days later. Blood culture was positive for Clostridium perfringens. A week after the procedure, the capsule had passed, and the patient was discharged with no abdominal symptoms and with tapering oral steroid dosage.

Zoom Image

Fig. 1 Radiograph showing mechanical ileus.

Zoom Image

Fig. 2 Redness, swelling, and aphthae in the jejunum.

Zoom Image

Fig. 3 Stenosis and ulceration.

Zoom Image

Fig. 4 Stenosis caused by ulceration.

Zoom Image

Fig. 5 Bleeding caused by capsule progression through stenotic area.

This case demonstrates an acute, rare, and serious complication of capsule endoscopy, and confirms that small-bowel follow-through does not reliably detect an intestinal stenosis, which should be suspected in patients with abdominal pain related to meals, and an involuntary weight loss. The risk of capsule retention is estimated to be 1.4 % in patients with suspected Crohn’s disease, and 13 % in patients with Crohn’s disease [4] [5]. In the present case, the standard diagnostic approach did not reveal the cause of symptoms, whereas capsule endoscopy enabled treatment and a positive therapeutic outcome.

Endoscopy_UCTN_Code_CPL_1AI_2AB

#

References

  • 1 Triester S L, Leighton J A, Leontiadis G I. et al . A metaanalysis of the yield of capsule endoscopy compared to other diagnostic modalities in patients with non-stricturing small bowel Crohn’s disease.  Am J Gastroenterol. 2006;  101 954-964
  • 2 Eliakim R, Fischer D, Suissa A. et al . Wireless capsule video endoscopy is a superior diagnostic tool in comparison to barium follow-through and computerized tomography in patients with suspected Crohn’s disease.  Eur J Gastroenterol Hepatol. 2003;  15 363-367
  • 3 Hara A, Leighton J, Height R. et al . Crohn disease of the small bowel.  Radiology. 2006;  238 128-134
  • 4 Cave D, Legnani P, de Francis R. et al . Consensus for capsule retention.  Endoscopy. 2005;  37 1065-1067
  • 5 Cheifetz A S, Kornbluth A A, Legnani P. et al . The risk of retention of the capsule endoscope in patients with known or suspected Crohn’s disease.  Am J Gastroenterol. 2006;  101 2218-2222

G. A. Dam, MD

PET-Centret

Aarhus Univeristy Hospital

Nørrebrogade 44

8000 Aarhus C

Denmark

Fax: +45-8949-3020

Email: gitte_dam@hotmail.com

#

References

  • 1 Triester S L, Leighton J A, Leontiadis G I. et al . A metaanalysis of the yield of capsule endoscopy compared to other diagnostic modalities in patients with non-stricturing small bowel Crohn’s disease.  Am J Gastroenterol. 2006;  101 954-964
  • 2 Eliakim R, Fischer D, Suissa A. et al . Wireless capsule video endoscopy is a superior diagnostic tool in comparison to barium follow-through and computerized tomography in patients with suspected Crohn’s disease.  Eur J Gastroenterol Hepatol. 2003;  15 363-367
  • 3 Hara A, Leighton J, Height R. et al . Crohn disease of the small bowel.  Radiology. 2006;  238 128-134
  • 4 Cave D, Legnani P, de Francis R. et al . Consensus for capsule retention.  Endoscopy. 2005;  37 1065-1067
  • 5 Cheifetz A S, Kornbluth A A, Legnani P. et al . The risk of retention of the capsule endoscope in patients with known or suspected Crohn’s disease.  Am J Gastroenterol. 2006;  101 2218-2222

G. A. Dam, MD

PET-Centret

Aarhus Univeristy Hospital

Nørrebrogade 44

8000 Aarhus C

Denmark

Fax: +45-8949-3020

Email: gitte_dam@hotmail.com

Zoom Image

Fig. 1 Radiograph showing mechanical ileus.

Zoom Image

Fig. 2 Redness, swelling, and aphthae in the jejunum.

Zoom Image

Fig. 3 Stenosis and ulceration.

Zoom Image

Fig. 4 Stenosis caused by ulceration.

Zoom Image

Fig. 5 Bleeding caused by capsule progression through stenotic area.