Abstract
Background The aim of this study was to evaluate whether the placement of a coaxial double-pigtail plastic stent (DPS) within a lumen-apposing metal stent (LAMS) may improve the safety of endoscopic ultrasound (EUS)-guided drainage of pancreatic fluid collections (PFCs).
Methods This was a retrospective cohort study including patients with PFCs and an indication for transmural drainage. Two strategies (LAMS alone or LAMS plus DPS) were used at the endoscopist’s discretion.
Results A total of 41 patients were treated (21 LAMS alone; 20 LAMS plus DPS). The characteristics of the PFCs, and the technical and clinical success rates did not differ between groups. The LAMS alone group had a significantly higher rate of adverse events than the LAMS plus DPS group (42.9 % vs. 10.0 %; P = 0.04). Bleeding was the most frequent adverse event observed.
Conclusions The addition of a coaxial DPS to LAMS was associated with a lower rate of adverse events in EUS-guided drainage of PFCs.
-
References
- 1 Itoi T, Binmoeller KF, Shah J. et al. Clinical evaluation of a novel lumen-apposing metal stent for endosonography-guided pancreatic pseudocyst and gallbladder drainage (with videos). Gastrointest Endosc 2012; 75: 870-876
- 2 Gornals JB, De la Serna-Higuera C, Sánchez-Yague A. et al. Endosonography-guided drainage of pancreatic fluid collections with a novel lumen-apposing stent. Surg Endosc 2013; 27: 1428-1434
- 3 Walter D, Will U, Sanchez-Yague A. et al. A novel lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: a prospective cohort study. Endoscopy 2015; 47: 63-67
- 4 Siddiqui AA, Adler DG, Nieto J. et al. EUS-guided drainage of peripancreatic fluid collections and necrosis by using a novel lumen-apposing stent: a large retrospective, multicenter U.S. experience (with videos). Gastrointest Endosc 2016; 83: 699-707
- 5 Bang JY, Hasan M, Navaneethan U. et al. Lumen-apposing metal stents (LAMS) for pancreatic fluid collection (PFC) drainage: may not be business as usual. Gut 2016; 66: 2054-2056
- 6 Gornals JB, Consiglieri CF, Busquets J. et al. Endoscopic necrosectomy of walled-off pancreatic necrosis using a lumen-apposing metal stent and irrigation technique. Surg Endosc 2016; 30: 2592-2602
- 7 Working Group IAP/APA Acute Pancreatitis Guidelines. IAP/APA evidence-based guidelines for the management of acute pancreatitis. Pancreatology 2013; 13 e1-e15
- 8 Banks PA, Bollen TL, Dervenis C. et al. Classification of acute pancreatitis – 2012: revision of the Atlanta classification and definitions by international consensus. Gut 2013; 62: 102-111
- 9 Cotton PB, Eisen GM, Aabakken L. et al. A lexicon for endoscopic adverse events: report of an ASGE workshop. Gastrointest Endosc 2010; 71: 446-454
- 10 Pérez-Miranda M. Endoscopic ultrasound-guided internal anastomosis using lumen-apposing stents in biliopancreatic diseases [dissertation]. Valladolid, Spain: University of Valladolid; 2015
- 11 Siddiqui AA, Kowalski TE, Loren DE. et al. Fully covered self-expanding metal stents versus lumen-apposing fully covered self-expanding metal stent versus plastic stents for endoscopic drainage of pancreatic walled-off necrosis: clinical outcomes and success. Gastrointest Endosc 2017; 85: 758-765
- 12 Vazquez-Sequeiros E, Baron TH, Pérez-Miranda M. et al. Evaluation of the short- and long-term effectiveness and safety of fully covered self-expandable metal stents for drainage of pancreatic fluid collections: results of a Spanish nationwide registry. Gastrointest Endosc 2016; 84: 450-457
- 13 Bang JY, Hawes R, Bartolucci A. et al. Efficacy of metal and plastic stents for transmural drainage of pancreatic fluid collections: a systematic review. Dig Endosc 2015; 27: 486-498
- 14 Stecher SS, Simon P, Friesecke S. et al. Delayed severe bleeding complications after treatment of pancreatic fluid collections with lumen-apposing metal stents. Gut 2017; 66: 1871-1872
- 15 Fabbri C, Luigiano C, Marsico M. et al. A rare adverse event resulting from the use of a lumen-apposing metal stent for drainage of a pancreatic fluid collection: “the buried stent”. Gastrointest Endosc 2015; 82: 585-587