RSS-Feed abonnieren
DOI: 10.1055/s-0034-1368784
Which Are The Best VO2 Sampling Intervals to Characterize Low to Severe Swimming Intensities?
Publikationsverlauf
accepted after revision 15. Januar 2014
Publikationsdatum:
03. Juni 2014 (online)
Abstract
Cardiorespiratory response in swimming has been used to better understand aerobic performance, especially by assessing oxygen uptake (VO2). The current study aimed to compare different VO2 time-averaging intervals throughout low to severe swimming intensities, hypothesizing that VO2 values are similar for different time averages at low to moderate and heavy swimming intensities, but not for the severe domain. 20 male trained swimmers completed an incremental protocol of 7×200 m until exhaustion (0.05 m/s increments and 30 s intervals). VO2 was measured by a portable gas analyser connected to a snorkel system. 6 time average intervals (breath-by-breath, 5, 10, 15, 20 and 30 s) were compared for all the protocol steps. Breath-by-breath and 5 s average exhibited higher VO2 values than averages≥10 s for all swimming intensities (P≤0.02; partial η2≤0.28). VO2 values did not differ between 10, 15, 20 and 30 s averages throughout the incremental protocol (P>0.05; partial η2≤0.05). Furthermore, 10 and 15 s averages showed the lowest VO2 mean difference (0.19 mL · kg−1 · min−1). For the 6 time average intervals analysed, 10 and 15 s averages were those that showed the lowest changes on VO2 values. We recommended the use of 10 and 15 s time averaging intervals to determine relevant respiratory gas exchange parameters along a large spectrum of swimming intensities.
-
References
- 1 Astorino TA. Alterations in VO2max and the VO2 plateau with manipulation of sampling intervals. Clin Physiol Func Imag 2009; 29: 60-67
- 2 Baldari C, Bonavolontà V, Emerenzian GP, Gallotta MC, Silva AJ, Guidetti L. Accuracy, reliability, linearity of Accutrend and Lactate Pro EBIO plus analyzer. Eur J Appl Physiol 2009; 107: 105-111
- 3 Baldari C, Fernandes R, Meucci M, Ribeiro J, Vilas-Boas JP, Guidetti L. Is the new Aqua Trainer® valid for VO2 assessment in swimming?. Int J Sports Med 2013; 34: 336-344
- 4 Barbosa T, Fernandes RJ, Keskinen KL, Vilas-Boas JP. The influence of stroke mechanics into energy cost of elite swimmers. Eur J Appl Physiol 2008; 103: 139-149
- 5 Barbosa T, Silva AJ, Reis AM, Costa M, Garrido N, Policarpo F, Reis VM. Kinematical changes in swimming front crawl and breaststroke with the AquaTrainer® snorkel. Eur J Appl Physiol 2010; 109: 1155-1162
- 6 Borg G, Hassmén P, Lagerström M. Perceived exertion related to heart rate and blood lactate during arm and leg exercise. Eur J Appl Physiol 1987; 56: 679-685
- 7 Burnley M, Jones A. Oxygen uptake kinetics as a determinant of sports performance. Eur J Appl Physiol 2007; 7: 63-79
- 8 Chidnok W, Dimenna FJ, Bailey SJ, Burnley M, Wilkerson DP, Vanhatalo A, Jones AM. VO2 max is not altered by self-pacing during incremental exercise. Eur J Appl Physiol 2013; 113: 529-539
- 9 Duffield R, Dawson B, Pinnington HC, Wong P. Accuracy and reliability of Cosmed K4b2 portable gas analysis system. J Sci Med Sport 2004; 7: 11-22
- 10 Fernandes RJ, Billat VL, Cruz AC, Colaço PJ, Cardoso CS, Vilas-Boas JP. Does net energy cost of swimming affect time to exhaustion at the individual’s maximal oxygen consumption velocity?. J Sports Med Phys Fitness 2006; 46: 373-380
- 11 Fernandes RJ, Keskinen K, Colaço P, Querido AJ, Machado LJ, Morais PA, Novais DQ, Marinho DA, Vilas-Boas JP. Time limit at VO2max velocity in elite crawl swimmers. Int J Sports Med 2008; 29: 145-150
- 12 Fernandes RJ, Sousa M, Machado L, Vilas-Boas JP. Step length and individual anaerobic threshold assessment in swimming. Int J Sports Med 2011; 32: 940-946
- 13 Fernandes RJ, de Jesus K, Baldari C, de Jesus K, Sousa AC, Vilas-Boas JP, Guidetti L. Different VO2max time-averaging intervals in swimming. Int J Sports Med 2012; 33: 1010-1015
- 14 Gayda M, Bosquet L, Martin J, Guiraud T, Lambert J, Nigam A. Comparison of gas exchange data using the Aquatrainer® system and facemask with Cosmed K4b2 during exercise in health subjects. Eur J Appl Physiol 2010; 109: 191-199
- 15 Harriss DJ, Atkinson G. Ethical standards in sport and exercise science research: 2014 Update. Int J Sports Med 2013; 34: 1025-1028
- 16 Hill DW, Stephens LP, Blumoff-Ross SA, Poole DC, Smith JC. Effect of sampling strategy on measures of VO2peak obtained using commercial breath-by-breath systems. Eur J Appl Physiol 2003; 89: 564-569
- 17 Jones AM, Vanhatalo A, Burnley M, Morton RH, Poole DC. Critical Power: implications for determination of VO2max and exercise tolerance. Med Sci Sports Exerc 2010; 42: 1876-1890
- 18 Komar J, Leprêtre PM, Alberty M, Vantorre J, Fernandes RJ, Hellard P, Chollet D, Seifert L. Effect of increasing energy cost on arm coordination in elite sprint swimmers. Hum Movement Sci 2012; 31: 620-629
- 19 Kuipers H, Rietjens G, Verstappen F, Schoenmakers H, Hofman G. Effects of stage duration in incremental running tests on physiological variables. Int J Sports Med 2003; 24: 486-491
- 20 Ludbrook J. Linear regression analysis for comparing two measures or methods of measurement: But which regression?. Clin Exp Pharmacol Physiol 2010; 37: 692-699
- 21 McLaughlin JE, King GA, Howley ET, Basset DR, Ainsworth BE. Validation of the cosmed K4b2 portable metabolic system. Int J Sports Med 2001; 22: 280-284
- 22 Midgley AW, McNaughton LR, Carroll S. Time at VO2max during intermittent treadmill running: Test protocol dependent or methodological artifact?. Int J Sports Med 2007; 28: 934-939
- 23 Myers J, Walsh D, Sullivan M, Froelicher V. Effect of sampling on variability and plateau in oxygen uptake. J Appl Physiol 1990; 68: 404-410
- 24 Özyener F, Rossiter HB, Ward SA, Whipp BJ. Influence of exercise intensity on the on- and off-transient kinetics of pulmonary oxygen uptake in humans. J Physiol 2001; 533: 891-902
- 25 Poole DC, Wilkerson DP, Jones AM. Validity of criteria for establishing maximal O2 uptake during ramp exercise tests. Eur J Appl Physiol 2008; 102: 403-410
- 26 Reis JF, Millet GP, Malatesta D, Roels B, Borrani F, Vleck VE, Alves FB. Are oxygen kinetics modified when using a respiratory snorkel?. Int J Sports Physiol Perform 2010; 5: 292-300
- 27 Reis JF, Alves FB, Bruno PM, Vleck V, Millet GP. Effects of aerobic fitness on oxygen uptake kinetics in heavy swimming intensity. Eur J Appl Physiol 2012; 112: 1689-1697
- 28 Reis JF, Alves FB, Bruno PM, Vleck V, Millet GP. Oxygen uptake kinetics and middle distance swimming performance. J Sci Med Sport 2012; 15: 58-63
- 29 Robergs RA, Dwyer D, Astorino A. Recommendations for improved data processing from expired gas analysis indirect calorimetry. Sport Med 2010; 40: 95-111
- 30 Roels B, Schmitt L, Libicz S, Bentley D, Richalet JP, Millet G. Specificity of VO2max and the ventilatory threshold in free swimming and cycle ergometry: comparison between triathletes and swimmers. Br J Sports Med 2005; 39: 965-968
- 31 Whipp BJ, Ward SA, Lamarra N, Davis JA, Wasserman K. Parameters of ventilatory and gas exchange dynamics during exercise. J Appl Physiol 1982; 52: 1506-1513