The Used Electrocautery Loop in the Equine Proximal Phalanx
Arthroscopic Removal of Three Type I Osteochondral Fragments of the Plantar Aspect in a Standardbred HorsePublikationsverlauf
Received 26. August 1998
Accepted 15. Mai 1999
Publikationsdatum:
08. Februar 2018 (online)
Summary
An 18-month-old 420 kg Standardbred colt was admitted for removal of three type I proximal plantar osteochondral fragments of the proximal phalanx. An electrocautery loop probe was used for the arthroscopic removal of the osteochondral fragments. Distension of the metatarsophalangeal joints was achieved using a 1.5% glycine solution. Under arthroscopic guidance, the soft tissue attachments of the osteochondral fragments were transected with the electrocautery loop probe. Once freed of all soft tissue attachments, the fragments were removed with a Ferris-Smith intervertebral disc rongeur. The electrocautery loop probe permitted an easy, precise and smooth dissection of intra-articular soft-tissue structures. Six weeks after the operation, the colt had returned to training. After eight months, the colt remained sound and was racing. The loop electrocautery probe was used as an alternative to manual sharp instruments in the arthroscopic treatment of Type I proximal plantar osteochondral fragments of the proximal phalanx.
An electrocautery loop probe was used in the arthroscopic treatment of type I proximal plantar osteochondral fragments of the proximal hind phalanx in a Standardbred horse. The loop electrocautery probe was used as an alternative to manual sharp instruments.
-
REFERENCES
- 1 Hardy J, Marcoux M, Breton L. Prévalences et description des fragments articulaires retrouvés au boulet chez le cheval standardbred. Méd Vét Québec 1987; 17: 57-61.
- 2 Foerner JJ, Barclay WP. Osteochondral fragments of the palmar/plantar aspect of the fetlock joint, in Proceedings. 33rd Am Assoc Equine Pract 1987; 739-44.
- 3 Fortier LA, Foerner JJ, Nixon AJ. Arthroscopic removal of axial osteochondral fragments of the plantar/palmar proximal aspect of the proximal phalanx in horses: 119 cases (1988-1992). J Am Vet Med Assoc 1995; 206: 71-4.
- 4 Mcllwraith CW. Diagnostic and surgical arthroscopy of the metacarpophalangeal and metatarsophalangeal joints. In: Diagnostic and surgical arthroscopy in the horse. Mcllwraith CW. (ed) Philadelphia: Lea & Febiger; 1990: 85-112.
- 5 Jann WH, Fackelman GE, Koblik PD, Perdue BD. Electrosurgical arthrotomy and excision of soft tissue masses in the metacarpophalangeal joint of the horse. Vet Surg 1986; 15: 429-34.
- 6 Boening KJ. Principles and basic techniques of intraarticular electro-surgery in the horse. Second Annual Meeting of European College of Veterinary Surgeons 1992; 2: 53.
- 7 Reagan B, Zarins B, Mankin HJ. Low conductivity irrigating solutions for arthroscopy. Arthroscopy 1991; 7: 105-7.
- 8 Bert JM. Use of 1. 5% glycine as a nonconductive fluid medium for arthroscopic electrosurgery. Arthroscopy 1987; 3: 248-52.
- 9 Bouré L, Marcoux M, Laverty S, Lepage OM. Use of Electrocautery Probes for Arthroscopic Removal of Apical Sesamoid Fracture Fragments in 18 Standardbred Horses. Vet Surg 1998; 27: 501.