Thorac Cardiovasc Surg 2007; 55(5): 284-287
DOI: 10.1055/s-2007-964959
Original Cardiovascular

© Georg Thieme Verlag KG Stuttgart · New York

Initial Clinical Experience with a Novel Biodegradable Ring in Patients with Functional Tricuspid Insufficiency: Kalangos Biodegradable Tricuspid Ring®

O. Burma1 , H. Ustunsoy1 , V. Davutoglu2 , M. A. Celkan1 , H. Kazaz1 , E. Pektok3
  • 1Department of Cardiovascular Surgery, Gaziantep University, Faculty of Medicine, Gaziantep, Turkey
  • 2Department of Cardiology, Gaziantep University, Faculty of Medicine, Gaziantep, Turkey
  • 3Service of Cardiovascular Surgery, University of Geneva, Geneva, Switzerland
Further Information

Publication History

received Nov 21, 2006

Publication Date:
16 July 2007 (online)

Abstract

Background: Tricuspid annuloplasty procedures have been widely performed in clinics for many years. The Kalangos Biodegradable Tricuspid Ring (Kalangos Biodegradable Tricuspid Ring®, Bioring SA, Lonay, Switzerland) is a novel prosthesis for the treatment of tricuspid insufficiency. The aim of this study was to evaluate the clinical and echocardiographic results of this novel prosthesis for functional tricuspid insufficiency. Methods: Between October 2005 and May 2006, 15 patients with the diagnosis of moderate or severe functional tricuspid insufficiency were treated by implantation of a Kalangos Biodegradable Tricuspid Ring®. All patients were evaluated clinically and by echocardiography preoperatively, and control tests were performed at the end of the 1st and 6th month following surgery. Results: Moderate and severe insufficiency was documented in 11 and 4 patients, respectively, in the preoperative tests. 1 and 6 months after surgery, 4 patients had trace and 1 patient had mild tricuspid insufficiency, while 10 patients had none. At the 1st and 6th month follow-up, systolic pulmonary arterial pressure, right atrial dimension and right ventricular diastolic diameter were found to be significantly lower than the preoperative values (p < 0.0001). The right atrial diameter and tricuspid valve area had decreased significantly at the end of the 1st month; however, no significant difference was found between the 1st and 6th month tests (p > 0.05). Three-quarters of the annuloplasty ring had degraded at 6 months. No complications related to the prosthesis or the procedure occurred within this period. Conclusions: Kalangos Biodegradable Ring is a promising prosthesis in patients with functional tricuspid insufficiency, with encouraging initial results.

References

  • 1 Nashef S AM, Roques F, Michel P, Gauducheau E, Lemeshow S, Salamon R. The EuroScore Study Group . European System for Cardiac Operative Risk Evaluation (EuroSCORE).  Eur J Cardiothorac Surg. 1999;  16 9-13
  • 2 Sahn D, DeMaria A, Kisslo J, Weyman A. Recommendations regarding quantification in M-mode echocardiography: results of a survey of echocardiographic measurements.  Circulation. 1978;  58 1072-1083
  • 3 Tajik A J, Seward J B, Hagler D J, Mair D D, Lie J T. Two-dimensional real-time ultrasonic imaging of the heart and great vessels. Technique, image orientation, structure identification, and validation.  Mayo Clin Proc. 1978;  53 271-303
  • 4 Tei C, Pilgrim J P, Shah P M, Ormiston J A, Wong M. The tricuspid valve annulus: study of size and motion in normal subjects and in patients with tricuspid regurgitation.  Circulation. 1982;  66 665-671
  • 5 Bommer W, Weinert L, Neumann A, Neef J, Mason D T, DeMaria A. Determination of right atrial and right ventricular size by two-dimensional echocardiography.  Circulation. 1979;  60 91-100
  • 6 Zoghbi W A, Enriquez-Sarano M, Foster E. et al . Recommendations for evaluation of the severity of the native valvular regurgitation with two-dimensional and Doppler echocardiography.  J Am Soc Echocardiogr. 2003;  16 777-802
  • 7 Kircher B J, Himelman R B, Schiller N B. Noninvasive estimation of right atrial pressure from the inspiratory collapse of the inferior vena cava.  Am J Cardiol. 1990;  66 493-496
  • 8 Kirklin J W, Pacifico A D. Surgery for acquired valvular heart disease.  N Engl J Med. 1973;  288 194-199
  • 9 De Vega N G. La annuloplastia seletiva regulable y permanete: una tecnica original para el tratamiento de la insufficiencia tricuspide.  Rev Esp Cardiol. 1972;  25 555-556
  • 10 Bonow R O, Carabello B, de Leon Jr A C. et al . Guidelines for the management of patients with valvular heart disease: executive summary: a report of the American College of Cardiology/American Heart Association task force on practice guidelines (committee on management of patients with valvular heart disease).  Circulation. 1998;  98 1949-1984
  • 11 Holper K, Haehnel J C, Augustin N, Sebening F. Surgery for tricuspid insufficiency: long-term follow-up after DeVega annuloplasty.  Thorac Cardiovasc Surg. 1993;  41 1-8
  • 12 Della Barbera M, Laborde F, Thiene G. et al . Sovering annuloplasty rings: Experimental pathology in the sheep model.  Cardiovasc Pathol. 2005;  14 96-103
  • 13 Kalangos A. Polydioxanone polymers for annuloplasty in valve repair.  Macromol Symp. 2006;  231 81-83
  • 14 Kazaz M, Celkan M A, Ustunsoy H, Baspinar O. Mitral annuloplasty with biodegradable ring for infective endocarditis: a new tool for the surgeon for valve repair in childhood.  Interact Cardiovasc Thorac Surg. DOI: 10.1510/icvts.2005.105833
  • 15 Kalangos A, Sierra J, Vala D. et al . Annuloplasty for valve repair with a biodegradable ring: an experimental study.  J Heart Valve Dis. 2006;  15 783-790
  • 16 Gatti G, Maffei G, Lusa A M, Pugliese P. Tricuspid valve repair with the Cosgrove-Edwards annuloplasty system: early clinical and echocardiographic results.  Ann Thorac Surg. 2001;  72 764-767
  • 17 Filsoufi F, Salzberg S P, Coutu M, Adams D H. A three-dimensional ring annuloplasty for the treatment of tricuspid regurgitation.  Ann Thorac Surg. 2006;  81 2273-2277

Dr. Oktay Burma

Department of Cardiovascular Surgery
Gaziantep University
Faculty of Medicine

27310 Gaziantep

Turkey

Phone: + 90 34 23 60 60 60

Fax: + 90 34 23 60 39 28

Email: oburma@hotmail.com