Endoscopy 2014; 46(07): 610-614
DOI: 10.1055/s-0034-1365446
Innovations and brief communications
© Georg Thieme Verlag KG Stuttgart · New York

Endocuff-assisted colonoscopy: a new accessory to improve adenoma detection rate? Technical aspects and first clinical experiences

Frank Lenze*
Department of Medicine B, University of Muenster, Muenster, Germany
,
Torsten Beyna*
Department of Medicine B, University of Muenster, Muenster, Germany
,
Philipp Lenz
Department of Medicine B, University of Muenster, Muenster, Germany
,
Hauke S. Heinzow
Department of Medicine B, University of Muenster, Muenster, Germany
,
Karin Hengst
Department of Medicine B, University of Muenster, Muenster, Germany
,
Hansjoerg Ullerich
Department of Medicine B, University of Muenster, Muenster, Germany
› Author Affiliations
Further Information

Publication History

submitted 20 August 2013

accepted after revision 12 February 2014

Publication Date:
13 May 2014 (online)

Background and study aims: The Endocuff is a new colonoscopy accessory that has been designed to improve both the adenoma detection rate and endoscope tip control.

Patients and methods: A total of 50 Endocuff-assisted colonoscopies were analyzed retrospectively with regard to safety, procedural success, and complications.

Results: The cecal intubation rate was 98 %, and the mean intubation time was 6.0 minutes (95 % confidence interval 5.3 – 6.6 minutes). The ileal intubation rate was 76 %. In 30 % of patients, the Endocuff caused small, superficial, “scratch-like” mucosal lesions. In all other patients, no Endocuff-associated complications were observed. A total of 36 adenomas were detected in 50 patients. The adenoma detection rate was 34 %.

Conclusions: Endocuff-assisted colonoscopy showed good procedural success rates in terms of cecal intubation rate and time, and a promising adenoma detection rate. Endocuff seems to improve endoscope tip control, especially during polypectomy. Endocuff may be a useful device for colorectal adenoma screening, and should be investigated in larger trials.

* These authors contributed equally to this work.


Figures e2 and Table e2

 
  • References

  • 1 Tsiamoulos ZP, Saunders BP. A new accessory, endoscopic cuff, improves colonoscopic access for complex polyp resection and scar assessment in the sigmoid colon (with video). Gastrointest Endosc 2012; 76: 1242-1245
  • 2 Leufkens AM, van Oijen MG, Vleggaar FP et al. Factors influencing the miss rate of polyps in a back-to-back colonoscopy study. Endoscopy 2012; 44: 470-475
  • 3 Rex DK, Cutler CS, Lemmel GT et al. Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies. Gastroenterology 1997; 112: 24-28
  • 4 Pickhardt PJ, Nugent PA, Mysliwiec PA et al. Location of adenomas missed by optical colonoscopy. Ann Intern Med 2004; 141: 352-359
  • 5 Rastogi A, Bansal A, Rao DS et al. Higher adenoma detection rates with cap-assisted colonoscopy: a randomised controlled trial. Gut 2012; 61: 402-408
  • 6 de Wijkerslooth TR, Stoop EM, Bossuyt PM et al. Adenoma detection with cap-assisted colonoscopy versus regular colonoscopy: a randomised controlled trial. Gut 2012; 61: 1426-1434
  • 7 Tee HP, Corte C, Al-Ghamdi H et al. Prospective randomized controlled trial evaluating cap-assisted colonoscopy vs standard colonoscopy. World J Gastroenterol 2010; 16: 3905-3910
  • 8 Sanchez-Yague A, Kaltenbach T, Yamamoto H et al. The endoscopic cap that can (with videos). Gastrointest Endosc 2012; 76: 169-178 , e161–162
  • 9 Yen AW, Leung JW, Leung FW. A novel method with significant impact on adenoma detection: combined water-exchange and cap-assisted colonoscopy. Gastrointest Endosc 2013; 77: 944-948
  • 10 Pox CP, Altenhofen L, Brenner H et al. Efficacy of a nationwide screening colonoscopy program for colorectal cancer. Gastroenterology 2012; 142: 1460-1467 , e1462