Background and study aims: A novel large-diameter, lumen-apposing, self-expanding metal stent with bilateral flanges was recently developed for endoscopic ultrasound (EUS)-guided transmural drainage of symptomatic pancreatic fluid collections (PFCs). The aim of this study was to evaluate the efficacy and safety of this stent in a large cohort.
Patients and methods: Patients with a PFC undergoing EUS-guided drainage with this novel stent were prospectively enrolled in this multicenter cohort study.
Results: There were 61 patients: 46 patients (75 %) with walled-off necrosis (WON) and 15 (25 %) with a pancreatic pseudocyst. Stent placement was technically successful in 60 patients (98 %, 95 %CI 95 % – 100 %). Clinical success, defined as resolution of clinical symptoms in combination with a decrease in the PFC size to ≤ 2 cm on imaging, was achieved in 93 % of patients with a pancreatic pseudocyst (95 %CI 77 % – 100 %) and in 81 % of patients with WON (95 %CI 69 % – 94 %). Treatment failure occurred in nine patients (16 %, 95 %CI 6 % – 26 %), including four patients who required surgical intervention. Stent removal was performed in 82 % of patients after a median of 32 days (range 2 – 178) and was rated as easy in all but one patient. In 10 patients, endoscopic stent removal was not performed because of stent migration (n = 3), stent dislodgement during necrosectomy (n = 3), stent removal during surgery (n = 2), or refusal by the patient (n = 2). In total, five major complications were reported (9 %, 95 %CI 2 % – 16 %), including PFC infection (n = 4) and perforation (n = 1).
Conclusion: EUS-guided drainage using this novel stent is feasible and the clinical results obtained are promising with a low major complication rate.
-
References
- 1 Seewald S, Ang TL, Kida M et al. EUS 2008 Working Group document: evaluation of EUS-guided drainage of pancreatic-fluid collections (with video). Gastrointest Endosc 2009; 69: S13-S21
- 2 Varadarajulu S, Christein JD, Tamhane A et al. Prospective randomized trial comparing EUS and EGD for transmural drainage of pancreatic pseudocysts (with videos). Gastrointest Endosc 2008; 68: 1102-1111
- 3 Varadarajulu S, Bang JY, Sutton BS et al. Equal efficacy of endoscopic and surgical cystogastrostomy for pancreatic pseudocyst drainage in a randomized trial. Gastroenterology 2013; 145: 583-590
- 4 Hookey LC, Debroux S, Delhaye M et al. Endoscopic drainage of pancreatic-fluid collections in 116 patients: a comparison of etiologies, drainage techniques, and outcomes. Gastrointest Endosc 2006; 63: 635-643
- 5 Talreja JP, Shami VM, Ku J et al. Transenteric drainage of pancreatic-fluid collections with fully covered self-expanding metallic stents (with video). Gastrointest Endosc 2008; 68: 1199-1203
- 6 Fabbri C, Luigiano C, Cennamo V et al. Endoscopic ultrasound-guided transmural drainage of infected pancreatic fluid collections with placement of covered self-expanding metal stents: a case series. Endoscopy 2012; 44: 429-433
- 7 Berzosa M, Maheshwari S, Patel KK et al. Single-step endoscopic ultrasonography-guided drainage of peripancreatic fluid collections with a single self-expandable metal stent and standard linear echoendoscope. Endoscopy 2012; 44: 543-547
- 8 Penn DE, Draganov PV, Wagh MS et al. Prospective evaluation of the use of fully covered self-expanding metal stents for EUS-guided transmural drainage of pancreatic pseudocysts. Gastrointest Endosc 2012; 76: 679-684
- 9 Weilert F, Binmoeller KF, Shah JN et al. Endoscopic ultrasound-guided drainage of pancreatic fluid collections with indeterminate adherence using temporary covered metal stents. Endoscopy 2012; 44: 780-783
- 10 Belle S, Collet P, Post S et al. Temporary cystogastrostomy with self-expanding metallic stents for pancreatic necrosis. Endoscopy 2010; 42: 493-495
- 11 Itoi T, Binmoeller KF, Shah J et al. Clinical evaluation of a novel lumen-apposing metal stent for endosonography-guided pancreatic pseudocyst and gallbladder drainage (with videos). Gastrointest Endosc 2012; 75: 870-876
- 12 Shah J, Shah JN, Waxman I et al. EUS-guided drainage of pancreatic pseudocysts (PP) utilizing a novel anchoring, covered self-expanding metal stent (Acsems): results from a prospective, multi-center study. Gastrointest Endosc 2013; 77: AB128
- 13 Gornals JB, De la Serna-Higuera C, Sanchez-Yague A et al. Endosonography-guided drainage of pancreatic fluid collections with a novel lumen-apposing stent. Surg Endosc 2013; 27: 1428-1434
- 14 Banks PA, Bollen TL, Dervenis C et al. Acute Pancreatitis Classification Working Group. Classification of acute pancreatitis -- 2012: revision of the Atlanta classification and definitions by international consensus. Gut 2013; 62: 102-111
- 15 Barresi L, Tarantino I, Curcio G et al. Buried stent: New complication of pseudocyst drainage with self-expandable metallic stent. Dig Endosc 2012; 24: 285