Subscribe to RSS
DOI: 10.1055/s-0038-1625958
Outcomes Following Low-Profile Mesh Plate Osteosynthesis of Patella Fractures
Publication History
05 June 2017
23 December 2017
Publication Date:
30 January 2018 (online)
Abstract
Treatment of patella fractures is fraught with complications and historically poor functional outcomes. A fixation method that allows for early mobilization and decreases symptomatic hardware rates will improve knee range of motion, postoperative functional status, and reoperation rates. The purpose of this study was to evaluate the functional outcomes after locked plate osteosynthesis of patella fractures at a Level 1 trauma center. A retrospective case series was conducted of patients who underwent open reduction internal fixation (ORIF) of a patella fracture using a locked mesh plating technique coupled with neutralization of forces on the distal pole of the patella. Twelve patients were evaluated at a mean follow-up of 19 months (range, 6–30) with physical exam, functional outcomes, and radiographs. There were 9 women and 3 men with an average age of 66.1 years (range, 53–75). Radiographic bony union was achieved in all patients by 3-month follow-up. Visual Analog Pain Score averaged 1.7 (median, 1.0; range, 0–8), the mean Knee Outcome Score – Activities of Daily Living Scale was 83.9 (median, 92.1; range, 45.7–100.0), the mean Short Form Musculoskeletal Function Assessment (SMFA) Function Index was 9.9 (median, 3.7; range, 0.7–41.2), and the mean SMFA Bother Index was 11.1 (median, 3.1; range, 0–62.5). The SF-36 Physical Component Score mean was 48.4 ± 8.5 and the SF-36 Mental Component Score mean was 54.1 ± 9.6. No complications developed and there were no reoperations for nonunion, infection, or symptomatic hardware. This study demonstrates that locked plate osteosynthesis for operative patella fractures can reliably achieve bony union with potentially superior functional outcomes as compared with traditional methods. Further studies are needed to evaluate plate fixation for patella fractures, but early results are promising.
-
References
- 1 Boström A. Fracture of the patella. A study of 422 patellar fractures. Acta Orthop Scand Suppl 1972; 143: 1-80
- 2 Melvin JS, Mehta S. Patellar fractures in adults. J Am Acad Orthop Surg 2011; 19 (04) 198-207
- 3 Hung LK, Chan KM, Chow YN, Leung PC. Fractured patella: operative treatment using the tension band principle. Injury 1985; 16 (05) 343-347
- 4 Kakazu R, Archdeacon MT. Surgical management of patellar fractures. Orthop Clin North Am 2016; 47 (01) 77-83
- 5 Bonnaig NS, Casstevens C, Archdeacon MT. , et al. Fix it or discard it? A retrospective analysis of functional outcomes after surgically treated patella fractures comparing ORIF with partial patellectomy. J Orthop Trauma 2015; 29 (02) 80-84
- 6 Agarwala S, Agrawal P, Sobti A. A novel technique of patella fracture fixation facilitating early mobilization and reducing re-operation rates. J Clin Orthop Trauma 2015; 6 (03) 207-211
- 7 Hoshino CM, Tran W, Tiberi JV. , et al. Complications following tension-band fixation of patellar fractures with cannulated screws compared with Kirschner wires. J Bone Joint Surg Am 2013; 95 (07) 653-659
- 8 Dy CJ, Little MT, Berkes MB. , et al. Meta-analysis of re-operation, nonunion, and infection after open reduction and internal fixation of patella fractures. J Trauma Acute Care Surg 2012; 73 (04) 928-932
- 9 Lazaro LE, Wellman DS, Sauro G. , et al. Outcomes after operative fixation of complete articular patellar fractures: assessment of functional impairment. J Bone Joint Surg Am 2013; 95 (14) e96
- 10 Wang CX, Tan L, Qi BC. , et al. A retrospective comparison of the modified tension band technique and the parallel titanium cannulated lag screw technique in transverse patella fracture. Chin J Traumatol 2014; 17 (04) 208-213
- 11 Patel VR, Parks BG, Wang Y, Ebert FR, Jinnah RH. Fixation of patella fractures with braided polyester suture: a biomechanical study. Injury 2000; 31 (01) 1-6
- 12 Taylor BC, Mehta S, Castaneda J, French BG, Blanchard C. Plating of patella fractures: techniques and outcomes. J Orthop Trauma 2014; 28 (09) e231-e235
- 13 Lorich DG, Warner SJ, Schottel PC, Shaffer AD, Lazaro LE, Helfet DL. Multiplanar fixation for patella fractures using a low-profile mesh plate. J Orthop Trauma 2015; 29 (12) e504-e510
- 14 Singer MS, Halawa AM, Adawy A. Outcome of low profile mesh plate in management of comminuted displaced fracture patella. Injury 2017; 48 (06) 1229-1235
- 15 Volgas D, Dreger TK. The use of mesh plates for difficult fractures of the patella. J Knee Surg 2017; 30 (03) 200-203
- 16 Thelen S, Schneppendahl J, Jopen E. , et al. Biomechanical cadaver testing of a fixed-angle plate in comparison to tension wiring and screw fixation in transverse patella fractures. Injury 2012; 43 (08) 1290-1295
- 17 Dickens AJ, Salas C, Rise L. , et al. Titanium mesh as a low-profile alternative for tension-band augmentation in patella fracture fixation: a biomechanical study. Injury 2015; 46 (06) 1001-1006
- 18 Chiang C-C, Chen W-M, Jeff Lin CF. , et al. Comparison of a minimally invasive technique with open tension band wiring for displaced transverse patellar fractures. J Chin Med Assoc 2011; 74 (07) 316-321
- 19 Rathi A, Swamy MK, Prasantha I, Consul A, Bansal A, Bahl V. Percutaneous tension band wiring for patellar fractures. J Orthop Surg (Hong Kong) 2012; 20 (02) 166-169
- 20 Kim MB, Lee YH, Shin WC, Baek GH. Locked tension band wiring using ring pins for patellar fractures: a method of minimising implant migration. Arch Orthop Trauma Surg 2014; 134 (11) 1537-1543
- 21 Lefaivre KA, O'Brien PJ, Broekhuyse HM, Guy P, Blachut PA. Modified tension band technique for patella fractures. Orthop Traumatol Surg Res 2010; 96 (05) 579-582
- 22 Egol K, Howard D, Monroy A, Crespo A, Tejwani N, Davidovitch R. Patella fracture fixation with suture and wire: you reap what you sew. Iowa Orthop J 2014; 34: 63-67
- 23 Kastelec M, Veselko M. Inferior patellar pole avulsion fractures: osteosynthesis compared with pole resection. J Bone Joint Surg Am 2004; 86-A (04) 696-701
- 24 LeBrun CT, Langford JR, Sagi HC. Functional outcomes after operatively treated patella fractures. J Orthop Trauma 2012; 26 (07) 422-426
- 25 Lorich DG, Fabricant PD, Sauro G. , et al. Superior outcomes after operative fixation of patella fractures using a novel plating technique: a prospective cohort study. J Orthop Trauma 2017; 31 (05) 241-247
- 26 Banks KE, Ambrose CG, Wheeless JS, Tissue CM, Sen M. An alternative patellar fracture fixation: a biomechanical study. J Orthop Trauma 2013; 27 (06) 345-351
- 27 Smith ST, Cramer KE, Karges DE, Watson JT, Moed BR. Early complications in the operative treatment of patella fractures. J Orthop Trauma 1997; 11 (03) 183-187