Case Report
Stabilization of a Physeal Fracture Using an Orthofix® Partially-threaded Kirschner Wire
Further Information
Publication History
Received 29 April 1998
Accepted 05 September 1998
Publication Date:
08 February 2018 (online)
Successful treatment of humeral condylar fractures requires accurate reduction and rigid internal fixation which can be difficult to achieve in toy and/or miniature breed dogs. Stabilization of a Salter-Harris type IV physeal fracture of the numeral condyle was simplified by using Orthofix® partially-threaded Kirschner wire and provided excellent clinical results in a 1.5 kg miniature pinscher
-
REFERENCES
- 1 Piermattei DL. An Atlas of Surgical Approaches to the Bones and Joints of the Dog and Cat. Philadelphia: WB Saunders Co; 1993: 168-71.
- 2 Vannini R, Olmstead ML, Smeak DD. Humeral condylar fractures caused by minor trauma in 20 adult dogs. J Am Anim Hosp Assoc 1988; 24: 355-62.
- 3 Vannini R, Smeak DD, Olmstead ML. Evaluation of surgical repair of 135 distal humeral fractures in dogs and cats. J Am Anim Hosp Assoc 1988; 24: 537-45.
- 4 Anderson TJ, Carmichael S, Miller A. Intercondylar humeral fracture in the dog: A review of 20 cases. J Small Anim Pract 1990; 31: 437-42.
- 5 Smith GK. Biomechanics pertinent to fracture etiology, reduction, and fixation. In. Newton CD, Nunamaker DM. (eds) Textbook of Small Animal Orthopaedics. Philadelphia: JB Lippincott Co; 1985: 195-230.
- 6 Morshdead D, Stambaugh JE. Kirschner wire fixation of lateral humeral condylar fractures in small dogs. Vet Surg 1984; 13: 1-5.
- 7 Orthofix®Fragment Fixation System Manual, Orthofix®Inc. Richardson, TX.
- 8 Brinker WO, Hohn RB, Prieur WD. Manual of Internal Fixation in Small Animals. Berlin, Heidelberg: Springer-Verlag; 1984: 50-5.