Subscribe to RSS
DOI: 10.1055/s-0038-1632721
Simple and multiple fractures of the radius treated with an external fixator
Comparison of healing of “simple” fractures and multiple fractures of the radius treated with external skeletal fixation in dogs: 56 cases (1983-1999)Publication History
Received
24 May 2001
Accepted
28 July 2001
Publication Date:
07 February 2018 (online)
Summary
The medical records of 56 dogs with diaphyseal fractures of the radius and ulna treated with Type lb or Type II external skeletal fixation were reviewed. The patients were referred to the College of Veterinary Medicine University of Illinois or the Purdue University School of Veterinary Medicine during the period from 1983 to 1999. There were thirty-two “simple” fractures and twenty-four multiple fractures. Twenty-four Type II frames and eight Type lb frames were used to treat the “simple” fractures. Twenty Type II frames and four Type lb frames were used to treat the multiple fractures. Eight of the thirty-two dogs with “simple” fractures and twelve of the twenty-four dogs with multiple fractures were admitted with open fractures. Open fractures were associated with a significantly longer time to fracture “bridging” Open reduction was used more frequently for the treatment of dogs with “simple” fractures. Open reduction resulted in greater bone contact at the fracture site. Contact at the fracture site resulted in a shorter time to removal of the external fixation. Clinical union was achieved in fifty of fifty-six fractures, with a mean time to removal of the fixation of 14.2 weeks. Significant difference, in the mean time to fracture “bridging” or the mean time to fixator removal, were not found between the “simple” and multiple fracture groups. Complications occurred in 25% (14/56) of fractures. Complications of fracture healing occurred in 18% (9/56) of fracture repairs, and fracture related complications occurred in 9%. The complications occurred more frequently in dogs weighing under 5 kg. There was not any difference between the “simple” and multiple fracture groups, with respect to the type or frequency of complications experienced. The results of this study indicate that stabilization, with an External Fixator, is an appropriate treatment for both “simple” and multiple diaphyseal fractures of the radius and ulna.
-
References
- 1 Aron DN, Palmer RH, Johnson AL. Biologic strategies and a balanced concept for repair of highly comminuted long bone fractures. Comp Cont Educ Vet Pract 1995; 17: 35-49.
- 2 Bach AW, Hansen ST. Plate versus external fixation in severe open tibial shaft fractures. ClinOrthop 1989; 241: 89-94.
- 3 Baumgaertel F, Gotzen L. The “biological” plate osteosynthesis in multi-fragment fractures of the para-articular femur. A prospective study. Unfallchirurg 1994; 97: 78-84.
- 4 Baumgaertel F, Perren SM, Rahn B. Animal experimental studies of ‘‘biological” plate osteosynthesis of multi-fragment fractures of the femur. Unfallchirurg 1994; 97: 19-27.
- 5 Bolhofner BR, Carmen B, Clifford P. The results of open reduction and internal fixation of distal femoral fractures using biologic (indirect) reduction techniques. J Orthop Trauma 1996; 10: 372-7.
- 6 Bolhofner BR. Indirect reduction and composite fixation of extraarticular proximal tibial fractures. Clin Orthop 1995; 315: 75-83.
- 7 Briggs BT, Chao EYS. The mechanical performance of the standard Hoffman - Vidal external fixation apparatus. J Bone Joint Surg Am 1982; 64-A: 566-73.
- 8 Brinker WO, Hohn RB, Prieur WD. eds. Manual of internal fixation in small animals. Berlin: Springer-Verlag; 1984
- 9 Chao EY, Kasman RA, An KN. Rigidity and stress analyses of external fracture fixation devices - a theoretical approach. J Biomech 1982; 15: 971-83.
- 10 Culvenor JA, Parker RJ. Collection of corticocancellous bone graft from the ilium of the dog using an acetabular reamer. J Small Anim Pract 1996; 37: 513-5.
- 11 Davidson EB. Vascular injury and delayed hemorrhage after antebrachial external skeletal fixation in a dog. Vet Comp Orthop Traumatol 1997; 10: 75-8.
- 12 Dudley M, Johnson AL, Olmstead ML. et al. Open reduction and bone plating stabilization, compared with closed reduction and external fixation, for treatment of comminuted tibial fractures: 47 cases (1980-1995). J Am Vet Med Assoc 1997; 211: 1008-12.
- 13 Egger EL, Histand MB, Norrdin RW, Konde LJ, Schwarz PD. Canine osteotomy healing when stabilized with decreasingly rigid fixation compared to constantly rigid fixation. Vet Comp Orthop Traumatol 1993; 182-7.
- 14 Gerber C, Mast JW, Ganz R. Biological internal fixation of fractures. Arch Orthop Trauma Sur» 1990; 109: 295-303.
- 15 Goodship AE, Watkins PE, Rigby HS, Kenwright J. The role of fixator frame stiffness in the control of fracture healing. An experimental study. J Biomech 1993; 26: 1027-35.
- 16 Gorse MJ. Using external skeletal fixation for fractures of the radius and ulna and tibia. Vet Med 1998; 463-7.
- 17 Green SA. Complications of external skeletal fixation. Clin Orthop 1983; 180: 109-16.
- 18 Guerin SR, Lewis DD, Lanz O. et al. Comminuted supracondylar humeral fractures repaired with a modified type I external skeletal fixator construct. J Small Anim Pract J 1998; 39: 525-32.
- 19 Harari J, Seguin B, Padgett SL. Principles of external skeletal fixation in small animal surgery. J Vet Med 1998; 445-54.
- 20 Heitemeyer U, Kemper F, Hierholzer G, Haines J. Severely comminuted femoral shaft fractures: treatment by bridging-plate osteosynthesis. Arch Orthop Trauma Surg 1987; 106: 327-30.
- 21 Johnson AL. Principles of bone grafting. Semin Vet Med Surg [Small Anim] 1991; 06: 90-9.
- 22 Johnson AL, Egger EL, Eurell JC, Losonsky JM. Biomechanics and biology of fracture healing with external skeletal fixation. Comp Cont Educ Vet Pract 1998; 20: 487-500.
- 23 Johnson AL, Kneller SK, Weigel RM. Radial and tibial fracture repair with external skeletal fixation. Vet Surg 1989; 18: 367-72.
- 24 Johnson AL, Seitz SE, Smith CW. et al. Closed reduction and type II external fixation for the treatment of twenty-three severely comminuted fractures of the radius and tibia (1990-1994). J Am Vet Med Assoc 1996; 209: 1445-8.
- 25 Johnson AL, Smith CW, Schaeffer DJ. Fragment reconstruction and bone plate fixation versus bridging plate fixation for treating highly comminuted femoral fractures in dogs: 35 cases (1987-1997). J Am Vet Med Assoc 1998; 08: 1157-61.
- 26 Kerwin SC, Lewis DD, Elkins AD. Bone grafting and banking. Comp Cont Educ Vet Pract 1991; 13: 1558-66.
- 27 Lappin MR, Aron DN, Herron HL, Malnati G. Fractures of the radius and ulna in the dog. J Am Anim Hosp Assoc 1983; 19: 643-50.
- 28 Larsen LJ, Roush JK, McLaughlin RM. Bone plate fixation of distal radius and ulna fractures in small and miniature breed dogs. J Am Anim Hosp Assoc 1999; 35: 243-50.
- 29 Lawyer RB, Lubbers LM. Use of the Hoffman apparatus in the treatment of unstable tibial fractures. J Bone Joint Surg Am 1980; 62-A: 1264-73.
- 30 McCartney W. Use of the modified acrylic external fixator in 54 dogs and 28 cats. Vet Rec 1998; 143: 330-4.
- 31 Olds RB, Sinibaldi KR, DeAngelis MP. et al. Autogenous cancellous bone grafting in small animals. J Am Anim Hosp Assoc 1973; 09: 454-57.
- 32 Ostrum RF, Chao EYS, Bassett CAL. et al. Bone injury, regeneration and repair. In: Simon SR. ed. Orthopaedic basic science. American academy of orthopaedic surgeons. 1994: 277-323.
- 33 Perren SM. The concept of biological plating using the limited contact-dynamic compression plate (LC-DCP). Scientific background, design and application. Injury 1991; 22 (Suppl. 01) 1-41.
- 34 Perren SM, Cordey J. The concept of interfragmentary strain. In: Uhthoff HK. ed. Current concepts of internal fixation of fractures. Berlin: Springer-Verlag; 1980: 63-77.
- 35 Perren SM, Klaus Pohler O. et al. The limited contact dynamic compression plate. Arch Orthop Surg 1990; 109: 304-10.
- 36 Riemer BL, Foglesong ME, Miranda MA. Femoral plating. Orthop Clin North Am 1994; 25: 625-33.
- 37 Rozbruch SR, Muller U, Gautier E, Ganz R. The evolution of femoral shaft plating technique. Clin Orthop 1998; 354: 195-208.
- 38 Schena CJ. The procurement of cancellous bone for grafting in small animal orthopedic surgery: A review of instrumentation, technique, and pathophysiology. J Am Anim Hosp Assoc 1983; 19: 695-701.
- 39 Sturmer KM. Elastic plate osteosynthesis, biomechanics, indications and technique in comparison with rigid osteosynthesis. Unfallchirurg 1996; 99: 8129.
- 40 Welch JA, Boudrieau RJ, DeJardin LM, Spodnick GJ. The intraosseous blood supply of the canine radius: implications for healing of distal fractures in small dogs. Vet Surg 1997; 26: 57-61.