CC BY-NC-ND 4.0 · Eur J Dent 2012; 06(02): 163-168
DOI: 10.1055/s-0039-1698946
Original Article
Dental Investigation Society

Evaluation of marginal fit of two allceramic copings with two finish lines

Gulce Subasi
a   Department of Prosthetic Dentistry, Faculty of Dentistry, Selcuk University, Konya
,
Nilgun Ozturk
b   Department of Prosthetic Dentistry, Faculty of Dentistry, Selcuk University, Konya
,
Inan Ozgur
b   Department of Prosthetic Dentistry, Faculty of Dentistry, Selcuk University, Konya
,
Nalan Bozogullari
b   Department of Prosthetic Dentistry, Faculty of Dentistry, Selcuk University, Konya
› Institutsangaben
Weitere Informationen

Publikationsverlauf

Publikationsdatum:
30. September 2019 (online)

ABSTRACT

Objectives: This in-vitro study investigated the marginal fit of two all-ceramic copings with 2 finish line designs

Methods: Forty machined stainless steel molar die models with two different margin designs (chamfer and rounded shoulder) were prepared. A total of 40 standardized copings were fabricated and divided into 4 groups (n=10 for each finish line-coping material). Coping materials tested were IPS e.max Press and Zirkonzahn; luting agent was Variolink II. Marginal fit was evaluated after cementation with a stereomicroscope (Leica MZ16). Two-way analysis of variance and Tukey-HSD test were performed to assess the influence of each finish line design and ceramic type on the marginal fit of 2 all-ceramic copings (α =.05)

Results: Two-way analysis of variance revealed no statistically significant differences for marginal fit relative to finish lines (P=.362) and ceramic types (P=.065)

Conclusion: Within the limitations of this study, both types of all-ceramic copings demonstrated that the mean marginal fit was considered acceptable for clinical application (≤120 μm). (Eur J Dent 2012;6:163-168)

 
  • References

  • 1 Bindl A, Mörmann WH. An up to 5-year clinical evaluation of posterior in-ceram CAD/CAM core crowns. Int J Prosthodont 2002;15:451-456
  • 2 Lehner CR, Schärer P. All-ceramic crowns. Curr Opin Dent 1992;2:45-52
  • 3 Mörmann WH, Bindl A. All-ceramic, chair-side computeraided design/computer-aided machining restorations. Dent Clin North Am 2002;46:405-426
  • 4 Tysowsky GW. The science behind lithium disilicate: a metal-free alternative. Dent Today 2009;28:112-113
  • 5 Guazzato M, Albakry M, Ringer SP, Swain MV. Strength, fracture toughness and microstructure of a selection of allceramic materials. Part II. Zirconia-based dental ceramics. Dent Mater 2004;20:449-456
  • 6 Stappert CF, Att W, Gerds T, Strub JR. Fracture resistance of different partial-coverage ceramic molar restorations: An in vitro investigation. J Am Dent Assoc 2006;137:514-522
  • 7 Oh SC, Dong JK, Lüthy H, Schärer P. Strength and microstructure of IPS Empress 2 glass-ceramic after different treatments. Int J Prosthodont 2000;13:468-472
  • 8 Yavuzyilmaz H, Turhan B, Bavbek B, Kurt E. All ceramic systems II (Tam seramik sistemleri II). The Journal of Gazi University Faculty of Dentistry (Gazi Üniversitesi Diş Hekimliği Fakültesi Dergisi) 2005;22:49-60
  • 9 Schwartz NL, Whitsett LD, Berry TG, Stewart JL. Unserviceable crowns and fixed partial dentures: life-span and causes for loss of serviceability. J Am Dent Assoc 1970;81:1395-1401
  • 10 Jacobs MS, Windeler AS. An investigation of dental luting cement solubility as a function of the marginal gap. J Prosthet Dent 1991;65:436-442
  • 11 Goldman M, Laosonthorn P, White RR. Microleakage--full crowns and the dental pulp. J Endod 1982;18:473-475
  • 12 Valderhaug J, Birkeland JM. Periodontal conditions in patients 5 years following insertion of fixed protheses. Pocket depth and loss of attachment. J Oral Rehabil 1976;3:237-243
  • 13 Valderhaug J, Heloe LA. Oral hygiene in a group of supervised patients with fixed prostheses. J Periodontol 1977;48:221-224
  • 14 Janenko C, Smales RJ. Anterior crowns and gingival health. Aust Dent J 1979;24:225-230
  • 15 Silness J. Periodontal conditions in patients treated with dental bridges. 3. The relationship between the location of the crown margin and the periodontal condition. J Periodontal Res 1970;5:225-229
  • 16 Smith BG. The effect of the surface roughness of prepared dentin on the retention of castings. J Prosthet Dent 1970;23:187-198
  • 17 Dedmon HW. The relationship between open margins and margin designs on full cast crowns made by commercial dental laboratories. J Prosthet Dent 1985;53:463-466
  • 18 Eames WB, O’Neal SJ, Monteiro J, Miller C, Roan JD Jr, Cohen KS. Techniques to improve the seating of castings. J Am Dent Assoc 1978;96:432-437
  • 19 Gavelis JR, Morency JD, Riley ED, Sozio RB. The effect of various finish line preparations on the marginal seal and occlusal seat of full crown preparations. J Prosthet Dent 1981;45:138-145
  • 20 Grajower R, Lewinstein I. A mathematical treatise on the fit of crown castings. J Prosthet Dent 1983;49:663-674
  • 21 Hunter AJ, Hunter AR. Gingival margins for crowns: a review and discussion. Part II: Discrepancies and configurations. J Prosthet Dent 1990;64:636-642
  • 22 Kay GW, Jablonski DA, Dogon IL. Factors affecting the seating and fit of complete crowns: a computer simulation study. J Prosthet Dent 1986;55:13-18
  • 23 Komine F, Iwai T, Kobayashi K, Matsumura H. Marginal and internal adaptation of zirconium dioxide ceramic copings and crowns with different finish line designs. Dent Mater J 2007;26:659-664
  • 24 Limkangwalmongkol P, Chiche GJ, Blatz MB. Precision of fit of two margin designs for metal-ceramic crowns. J Prosthodont 2007;16:233-237
  • 25 Pascoe DF. An evaluation of the marginal adaptation of extracoronal restorations during cementation. J Prosthet Dent 1983;49:657-662
  • 26 Quintas AF, Oliveira F, Bottino MA. Vertical marginal discrepancy of ceramic copings with different ceramic materials, finish lines, and luting agents: an in vitro evaluation. J Prosthet Dent 2004;92:250-257
  • 27 Syu JZ, Byrne G, Laub LW, Land MF. Influence of finish-line geometry on the fit of crowns. Int J Prosthodont 1993;6:25-30
  • 28 Wang CJ, Millstein PL, Nathanson D. Effects of cement, cement space, marginal design, seating aid materials, and seating force on crown cementation. J Prosthet Dent 1992;67:786-790
  • 29 Naert I, Van der Donck A, Beckers L. Precision of fit and clinical evaluation of all-ceramic full restorations followed between 0.5 and 5 years. J Oral Rehabil 2005;32:51-57
  • 30 Sulaiman F, Chai J, Jameson LM, Wozniak WT. A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera crowns. Int J Prosthodont 1997;10:478-484
  • 31 Yeo IS, Yang JH, Lee JB. In vitro marginal fit of three allceramic crown systems. J Prosthet Dent 2003;90:459-464
  • 32 Pera P, Gilodi S, Bassi F, Carossa S. In vitro marginal adaptation of alumina porcelain ceramic crowns. J Prosthet Dent 1994;72:585-590
  • 33 Campagni WV, Preston JD, Reisbick MH. Measurement of paint-on die spacers used for casting relief. J Prosthet Dent 1982;47:606-611
  • 34 Campbell SD. Comparison of conventional paint-on die spacers and those used with the all-ceramic restorations. J Prosthet Dent 1990;63:151-155
  • 35 Iwai T, Komine F, Kobayashi K, Saito A, Matsumura H. Influence of convergence angle and cement space on adaptation of zirconium dioxide ceramic copings. Acta Odontol Scand 2008;66:214-218
  • 36 Beschnidt SM, Strub JR. Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth. J Oral Rehabil 1999;26:582-593
  • 37 Rinke S, Hüls A, Jahn L. Marginal accuracy and fracture strength of conventional and copy-milled all-ceramic crowns. Int J Prosthodont 1995;8:303-310
  • 38 Al-Rabab’ah MA, Macfarlane TV, McCord CF. Vertica marginal and internal adaptation of all-ceramic copings made by CAD/CAM technology. Eur J Prosthodont Rest Dent 2008;16;109-115
  • 39 Bindl A, Mörmann WH. Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations. J Oral Rehabil 2005;32:441-447
  • 40 Holden JE, Goldstein GR, Hittelman EL, Clark EA. Comparison of the marginal fit of pressable ceramic to metal ceramic restorations. J Prosthodont 2009;18:645-648
  • 41 Goldin EB, Boyd NW 3rd, Goldstein GR, Hittelmann EL, Thompson VP. Marginal fit of leucite-glass pressable ceramic restorations and ceramic-pressed-to-metal restorations. J Proshtet Dent 2005;93:143-147
  • 42 McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J 1971;131:107-111