DOI: 10.1055/s-0040-1713731
Successful Treatment of Driveline Infection with Vacuum-Assisted Closure Therapy and Instillation Therapy
Publication History
03 September 2019
22 December 2019
Publication Date:
12 October 2020 (online)

Abstract
Background Driveline infection is a serious complication in left ventricular assist device (LVAD) patients. We report the case of a patient who was successfully treated by combining instillation and vacuum-assisted closure (VAC) therapy.
Case Description A 65-year-old LVAD patient presented with recurrent driveline infection. Local therapy with VAC therapy in combination with instillation of polyhexanide was performed for 2 weeks. The patient remains free from infection for twelve months by now.
Conclusion This case is the first to present the combination of polyhexanide instillation with VAC as treatment for driveline infection. This therapy may thus be an option for patients who lack any other surgical option.
-
References
- 1 Pavlovic NV, Randell T, Madeira T, Hsu S, Zinoviev R, Abshire M. Risk of left ventricular assist device driveline infection: a systematic literature review. Heart Lung 2019; 48 (02) 90-104
- 2 Chahal D, Sepehry AA, Nazzari H, Wright AJ, Toma M. The impact of left ventricular assist device infections on postcardiac transplant outcomes: a systematic review and meta-analysis. ASAIO J 2019; 65 (08) 827-836
- 3 Kurihara C, Nishimura T, Kinoshita O. , et al. Successful treatment of mediastinitis after ventricular assist device implantation with rerouting of the outflow vascular prosthesis. J Artif Organs 2011; 14 (02) 155-158
- 4 Kimura M, Nishimura T, Kinoshita O. , et al. Successful treatment of pump pocket infection after left ventricular assist device implantation by negative pressure wound therapy and omental transposition. Ann Thorac Cardiovasc Surg 2014; 20 (Suppl): 842-845
- 5 Walter V, Stock UA, Soriano-Romero M, Schnitzbauer A, Moritz A, Beiras-Fernandez A. Eradication of a chronic wound and driveline infection after redo-LVAD implantation. J Cardiothorac Surg 2014; 9: 63
- 6 Yu AW, Rippel RA, Smock E, Jarral OA. In patients with post-sternotomy mediastinitis is vacuum-assisted closure superior to conventional therapy?. Interact Cardiovasc Thorac Surg 2013; 17 (05) 861-865
- 7 Baradarian S, Stahovich M, Krause S, Adamson R, Dembitsky W. Case series: clinical management of persistent mechanical assist device driveline drainage using vacuum-assisted closure therapy. ASAIO J 2006; 52 (03) 354-356
- 8 Lehner B, Fleischmann W, Becker R, Jukema GN. First experiences with negative pressure wound therapy and instillation in the treatment of infected orthopaedic implants: a clinical observational study. Int Orthop 2011; 35 (09) 1415-1420
- 9 Idris A, Hart A, Branam S, Guglin M. VeraFlo negative pressure wound therapy with household bleach for refractory driveline infection in a patient with left ventricular assist device. VAD J 2015; 1: 1-10