ABSTRACT
Large discrepancies between factor VIII assay methods have been reported from pharmacokinetic studies of recombinant factor VIII concentrates. In the assay of postinfusion patient plasma samples, traditional activated partial thromboplastin time (aPTT)-based one-stage clotting methods usually give results that are 20 to 50% lower than those obtained by chromogenic substrate assays. Investigations into the cause of these discrepancies have shown that the choice of phospholipid in the one-stage assay is crucial. The use of platelets or liposomes resembling platelet factor 3 instead of traditional aPTT reagents results in an increase in the apparent one-stage activity and a fairly good correlation with the chromogenic results. These and other functional test results, antigen measurements as well as clinical data, support the view that the chromogenic assay most accurately reflects the therapeutic effect. In addition to the differences among assay methods, there is also a discrepancy between the World Health Organization (WHO) standards for concentrates and plasma. The use of product-specific standards, prepared by diluting the factor VIII concentrate into hemophilic plasma, when assaying postinfusion plasma samples seems to be a feasible approach to overcome the problems encountered in pharmacokinetic studies.
KEYWORDS
Hemophilia A - factor VIII - recombinant - assay - pharmacokinetics
REFERENCES
- 1 Barrowcliffe T W. Standardisation and assay. Semin Thromb Hemost . 1993; 19 73-79
- 2 Barrowcliffe T W, Raut S, Hubbard A R. Discrepancies in potency assessment of recombinant FVIII concentrates. Haemophilia . 1998; 4 634-640
- 3 Barrowcliffe T W. Recommendations for the assay of high-purity factor VIII concentrates. Thromb Haemost . 1993; 70 876-877
- 4 Morfini M, Lee M, Messori A. The design and analysis of half-life and recovery studies for factor VIII and factor IX. Thromb Haemost . 1991; 66 384-386
- 5 Lusher J M, Hillman-Wiseman C, Hurst D. In vivo recovery with products of very high purity-assay discrepancies. Haemophilia . 1998; 4 641-645
- 6 Lee C A, Owens D, Bray G. Pharmacokinetics of recombinant factor VIII (Recombinate) using one-stage clotting and chromogenic factor VIII assay. Thromb Haemost . 1999; 82 1644-1647
- 7 Mikaelsson M, Oswaldsson U, Frank L. Comparison of activity and antigen measurements in a pharmacokinetic study of recombinant factor VIII SQ (Abst 131). Haemophilia . 1998; 4 187
- 8 Nilsson I M, Barrowcliffe T W, Schimpf K. Factor VIII concentrates and their clotting activity. Scand J Hematol . 1984; 33(Suppl 41) 13-68
- 9 Rosén S. Assay of factor VIII:C with chromogenic substrate. Scand J Hematol . 1984; 33(Suppl 40) 139-145
- 10 Carlebjörk G, Oswaldsson U, Rosén S. A simple and accurate microplate assay for determination of factor VIII activity. Thromb Res . 1987; 47 5-14
- 11 Mikaelsson M, Oswaldsson U, Sandberg H. Influence of phospholipids on the assessment of factor VIII activity. Haemophilia . 1998; 4 646-650
-
12 Mikaelsson M. Assay discrepancies in pharmacokinetic studies of recombinant factor VIII concentrates. Presented at the SSC/ISTH subcommittee meeting, Maastricht, The Netherlands; June 15, 2000
- 13 Mikaelsson M, Oswaldsson U. One-stage factor VIII assays are affected by both type and amount of phospholipids (Abst 1805). Thromb Haemost . 1999; 82(Suppl) 574
- 14 Roberts H R, Monroe D M, Oliver J A. Newer concepts of blood coagulation. Haemophilia . 1998; 4 331-334
- 15 Mann K G. Biochemistry and physiology of blood coagulation. Thromb Haemost . 1999; 82 165-174
- 16 Bajaj S P, Joist J H. New insights into how blood clots: implications for the use of aPTT and PT as coagulation screening tests and in monitoring of anticoagulant therapy. Semin Thromb Hemost . 1999; 25 407-418
- 17 Nordfang O, Valentin S, Beck T C, Hedner U. Inhibition of extrinsic pathway inhibitor shortens the coagulation time of normal plasma and of hemophilia plasma. Thromb Haemost . 1991; 66 464-467
- 18 Aaro A, Oswaldsson U, Mikaelsson M. Comparison of r-VIII SQ with other factor VIII concentrates in the dilute thromboplastin test (Abst 34). Haemophilia . 1998; 4 163
- 19 Berntorp E. Second generation, B-domain deleted recombinant factor VIII. Thromb Haemost . 1997; 78 256-260
- 20 Oswaldsson U, Frank L, Mikaelsson M. Comparison of normal plasma and product-specific standards in the assessment of post-injection factor VIII activity (Abst 1806). Thromb Haemost . 1999; (Suppl) 574