Abstract
Background and Study Aims: Capsule endoscopy (CE) and double-balloon enteroscopy (DBE) have been introduced as modalities for examining the entire small bowel. The aim of the present study was to assess the clinical effects of CE and DBE to consider the roles of CE and DBE and the indications for the procedures in patients with suspected small-bowel bleeding.
Patients and Methods: Between June 2004 and January 2005, 32 patients in whom a site of bleeding in the gastrointestinal tract had not been identified were enrolled in the study. Twenty-eight patients were examined with both methods. Bleeding sources were categorized as either A1 lesions (immediate hemostatic procedures required) or A2 lesions (close observation required). CE and DBE were evaluated with regard to whether or not they were capable of accessing the entire small bowel and provided a diagnosis, and the access and diagnostic rates were calculated.
Results: On CE, 13 patients were diagnosed with A1 lesions and six with A2 lesions; on DBE, 11 had A1 lesions and one had an A2 lesion. The access rate for the entire small intestine on CE was 90.6 % (29 of 32), significantly higher than with DBE at 62.5 % (10 of 16; P < 0.05). The diagnostic rate on CE was 59.4 % (19 of 32), higher than with DBE at 42.9 % (12 of 28; P = 0.30), but not significantly different. Among patients with A1 lesions who were diagnosed with DBE, histological diagnoses were obtained in six of the 11, and three patients were treated.
Conclusions: In many suspected small-bowel bleeding cases, CE should be selected for the initial diagnosis and DBE for treatment or histopathological diagnosis after detection of the bleeding site on CE.
References
- 1 Soehendra N. Endoscopic therapy of upper gastrointestinal bleeding. Endoscopy. 1987; 19 205-206
- 2 Potter G D, Sellin J H. Lower gastrointestinal bleeding. Gastrointest Clin North Am. 1988; 17 341-356
- 3 Lewis B S. The history of enteroscopy. Gastrointest Clin North Am. 1999; 9 1-11
- 4 Delmotte J S, Gay G J, Houcke P H. et al . Intraoperative endoscopy. Gastrointest Clin North Am. 1999; 9 61-69
- 5 Weaver L T, Austin S, Cole T J. Small intestinal length: a factor essential for gut adaptation. Gut. 1991; 32 1321
- 6 Iddan G, Meron G, Glukhovsky A. et al . Wireless capsule endoscopy. Nature. 2000; 415 417
- 7 Appleyard M, Glukhovsky A, Swain P. Wireless-capsule diagnostic endoscopy for recurrent small-bowel bleeding. N Engl J Med. 2001; 344 232-233
- 8 Pennazio M, Santucci R, Rondonotti E. et al . Outcome of patients with obscure gastrointestinal bleeding after capsule endoscopy: report of 100 consecutive cases. Gastroenterology. 2004; 126 643-653
- 9 Yamamoto H, Sekine Y, Sato Y. et al . Total enteroscopy with a nonsurgical steerable double-balloon method. Gastrointest Endosc. 2001; 53 216-220
- 10 Yamamoto H, Yano T, Kita H. et al . New system of double-balloon enteroscopy for diagnosis and treatment of small intestinal disorders. Gastroenterology. 2003; 125 1556
- 11 Ohmiya N, Taguchi A, Shirai K. et al . Endoscopic resection of Peutz-Jeghers polyps throughout the small intestine at double-balloon enteroscopy without laparotomy. Gastrointest Endosc. 2005; 61 140-147
- 12 Delvaux M, Fassler I, Gay G. et al . Clinical usefulness of the endoscopic video capsule as the initial intestinal investigation in patients with obscure digestive bleeding: validation of a diagnostic strategy based on the patient outcome after 12 months. Endoscopy. 2004; 36 1067-1073
- 13 Yamamoto H, Kita H, Sunada K. et al . Clinical outcomes of double-balloon endoscopy for the diagnosis and treatment of small-intestinal diseases. Clin Gastroenterol Hepatol. 2004; 2 1010-1016
- 14 Swain P. Wireless capsule endoscopy. Gut. 2003; 52 (Suppl 4) 48-50
- 15 Fischer D, Schreiber R, Levi D. et al . Capsule endoscopy: the localization system. Gastrointest Clin North Am. 2004; 14 25-31
- 16 Yamamoto H, Sugano K. A new method of enteroscopy: the double-balloon method. Can J Gastroenterol. 2003; 17 273-274
- 17 May A, Nachbar L, Wsardak A. et al . Double-balloon enteroscopy: preliminary experience in patients with obscure gastrointestinal bleeding or chronic abdominal pain. Endoscopy. 2003; 35 985-991
- 18 Mylonaki M, Fritscher-Ravens A, Swain P. Wireless capsule endoscopy: a comparison with push enteroscopy in patients with gastroscopy and colonoscopy negative gastrointestinal bleeding. Gut. 2003; 52 1122-1126
- 19 Hartmann D, Schilling D, Bolz G. et al . Capsule endoscopy versus push enteroscopy in patients with occult gastrointestinal bleeding. Z Gastroenterol. 2003; 41 377-382
- 20 Hara A K, Leighton J A, Sharma V E. et al . Small bowel: preliminary comparison of capsule endoscopy with barium study and CT. Radiology. 2004; 230 260-265
- 21 Fireman Z, Maharaja E, Broide E. et al . Diagnosing small bowel Crohn’s disease with wireless capsule endoscopy. Gut. 2003; 52 390-392
- 22 Herrerias J M, Caunedo A, Rodriguez-Tellez M. et al . Capsule endoscopy in patients with suspected Crohn’s disease and negative endoscopy. Endoscopy. 2003; 35 564-568
- 23 Saurin J C, Delvaux M, Gaudin J L. Diagnostic value of endoscopic capsule in patients with obscure digestive bleeding: blinded comparison with video push-enteroscopy. Endoscopy. 2003; 35 576-584
- 24 Adler D G, Knipschield M, Gostout C. A prospective comparison of capsule endoscopy and push enteroscopy in patients with GI bleeding of obscure origin. Gastrointest Endosc. 2004; 59 492-498
- 25 Ell C, Remke S, May A. et al . The first prospective controlled trial comparing wireless capsule endoscopy with push enteroscopy in chronic gastrointestinal bleeding. Endoscopy. 2002; 34 685-689
Y. Niwa, M.D., Ph. D.
Department of Internal Medicine · Division of Therapeutic Medicine · Nagoya University Graduate School of Medicine
65 Tsuruma-cho, Showa-ku · Nagoya 466-8550 · Japan
Fax: +81-52-744-2180
Email: yniwa@med.nagoya-u.ac.jp