Subscribe to RSS
DOI: 10.1055/s-2007-1010230
© Georg Thieme Verlag Stuttgart · New York
Are In-Vitro Platelet Function Tests Useful in Predicting Blood Loss Following Open Heart Surgery?
Publication History
1998
Publication Date:
19 March 2008 (online)
![](https://www.thieme-connect.de/media/thoracic/199804/lookinside/thumbnails/10.1055-s-2007-1010230-1.jpg)
Abstract
Background: We investigated the suitability of two commercially available in-vitro bleeding tests (IVBT), the PFA-100® and the Hepcon® “ HMS, to predict blood loss following operations with extracorporeal circulation (ECC) and compared them with conventional coagulation studies. Methods: In 40 patients subjected to elective open heart surgery with ECC a blood sample was taken before and after ECC to measure platelet count, prothrombin time, aPTT, D-dimers, fibrinogen, and PFA-100® and Hepcon® “ HMS data. The postoperative blood loss was recorded hourly until removal of drains. Results: A significant correlation wasfound between total blood loss (250-1750 ml) and the preoperative PFA-100® “ (r= 0.41, p = 0.022), the preoperative platelet count (r=-0.42, p = 0.007), the preoperative D-dimer concentration in the plasma (r = 0.41, p = 0.01), and duration of ECC (r = 0.35, p = 0.044). There was no significant correlation between blood loss and the Hepcon® HMS system. Conclusions: Although a significant correlation was found between blood loss and the PFA-100 IVBT, the practical value of these tests in the clinical situation is limited due to a great variability in individual results.
Key words
Open heart surgery - Blood loss - Platelet function - In vitro bleeding test