Subscribe to RSS

DOI: 10.4103/1305-7456.143635
Geometric analysis of root canals prepared by single twisted file in three different operation modes
Publication History
Publication Date:
25 September 2019 (online)

ABSTRACT
Objective: The aim of this study was to evaluate and compare the effects of a single twisted file (TF) instrument in three different operation modes on the preparation of curved root canals in human molars and to explore a new possible method in canal shaping in the clinic setting. Materials and Methods: A total of 105 selected root canals with an angle of curvature ranging from 20° to 35° were divided into the following three groups with 35 samples each according to the different operation mode in canal preparation: “continuous rotation-500” (CR, 500 rpm), reciprocating movement-300 (RM-300 rpm) and CR-300 rpm. Root canals were prepared by single file (a size 25/0.06 TF). The pre- and post-instrumented images of the sections were scanned using a cone-beam computed tomography scanner to measure the root transportation and centering ratio. The data were evaluated at 1.5 mm, 3.0 mm and 6.0 mm positions from the apex. The significance level was set at P < 0.05. Results: The results showed a statistically significant difference in root transportation that was only found in cross-sections 3.0 mm from the anatomic apex between group “CR-500” and group “CR-300.” In addition, a significant difference in centering ratio was found between group “RM-300” and group “CR-300.” There was no significant difference in the two indices among the three groups at cross-sections 1.5 mm and 6 mm from the apex. Conclusions: Under the three conditions of this study, the continuous rotation mode has better shaping ability in root canal preparation than the RM mode when used with a TF single file (size 25/0.06).
-
REFERENCES
- 1 Guelzow A, Stamm O, Martus P, Kielbassa AM. Comparative study of six rotary nickel-titanium systems and hand instrumentation for root canal preparation. Int Endod J 2005; 38: 743-52
- 2 Schirrmeister JF, Strohl C, Altenburger MJ, Wrbas KT, Hellwig E. Shaping ability and safety of five different rotary nickel-titanium instruments compared with stainless steel hand instrumentation in simulated curved root canals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2006; 101: 807-13
- 3 Sonntag D, Ott M, Kook K, Stachniss V. Root canal preparation with the NiTi systems K3, Mtwo and ProTaper. Aust Endod J 2007; 33: 73-81
- 4 Vaudt J, Bitter K, Neumann K, Kielbassa AM. Ex vivo study on root canal instrumentation of two rotary nickel-titanium systems in comparison to stainless steel hand instruments. Int Endod J 2009; 42: 22-33
- 5 Alapati SB, Brantley WA, Svec TA, Powers JM, Mitchell JC. Scanning electron microscope observations of new and used nickel-titanium rotary files. J Endod 2003; 29: 667-9
- 6 You SY, Bae KS, Baek SH, Kum KY, Shon WJ, Lee W. Lifespan of one nickel-titanium rotary file with reciprocating motion in curved root canals. J Endod 2010; 36: 1991-4
- 7 Shen Y, Qian W, Abtin H, Gao Y, Haapasalo M. Fatigue testing of controlled memory wire nickel-titanium rotary instruments. J Endod 2011; 37: 997-1001
- 8 Yared G. Canal preparation using only one Ni-Ti rotary instrument: Preliminary observations. Int Endod J 2008; 41: 339-44
- 9 Yared G. Canal preparation with only one reciprocating instrument without prior hand filing: A new concept. Aust Dent Pract 2011; 22: 178
- 10 De-Deus G, Moreira EJ, Lopes HP, Elias CN. Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement. Int Endod J 2010; 43: 1063-8
- 11 Varela-Patiño P, Ibañez-Párraga A, Rivas-Mundiña B, Cantatore G, Otero XL, Martin-Biedma B. Alternating versus continuous rotation: A comparative study of the effect on instrument life. J Endod 2010; 36: 157-9
- 12 Hülsmann M, Peters OA, Dummer PM. Mechanical preparation of root canals: Shaping goals, techniques and means. Endod Topics 2005; 10: 30-76
- 13 Gambarini G, Grande NM, Plotino G, Somma F, Garala M, De Luca M. et al. Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods. J Endod 2008; 34: 1003-5
- 14 Larsen CM, Watanabe I, Glickman GN, He J. Cyclic fatigue analysis of a new generation of nickel titanium rotary instruments. J Endod 2009; 35: 401-3
- 15 Gambarini G, Gerosa R, De Luca M, Garala M, Testarelli L. Mechanical properties of a new and improved nickel-titanium alloy for endodontic use: An evaluation of file flexibility. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 105: 798-800
- 16 Hashem AA, Ghoneim AG, Lutfy RA, Foda MY, Omar GA. Geometric analysis of root canals prepared by four rotary NiTi shaping systems. J Endod 2012; 38: 996-1000
- 17 Bhagabati N, Yadav S, Talwar S. An in vitro cyclic fatigue analysis of different endodontic nickel-titanium rotary instruments. J Endod 2012; 38: 515-8
- 18 Pedullà E, Grande NM, Plotino G, Gambarini G, Rapisarda E. Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments. J Endod 2013; 39: 258-61
- 19 Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol 1971; 32: 271-5
- 20 Nagy CD, Szabó J, Szabó J. A mathematically based classification of root canal curvatures on natural human teeth. J Endod 1995; 21: 557-60
- 21 Zhu YQ. Clinical key-points about fine and curved root canal preparation. Chin J Pract Stomatol 2011; 4: 518-21
- 22 Gambill JM, Alder M, del Rio CE. Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomography. J Endod 1996; 22: 369-75
- 23 Gergi R, Rjeily JA, Sader J, Naaman A. Comparison of canal transportation and centering ability of twisted files, Pathfile-ProTaper system, and stainless steel hand K-files by using computed tomography. J Endod 2010; 36: 904-7
- 24 Thompson SA, Dummer PM. Shaping ability of Hero 642 rotary nickel-titanium instruments in simulated root canals: Part 2. Int Endod J 2000; 33: 255-61
- 25 Roane JB, Sabala CL, Duncanson Jr MG. The “balanced force” concept for instrumentation of curved canals. J Endod 1985; 11: 203-11
- 26 Franco V, Fabiani C, Taschieri S, Malentacca A, Bortolin M, Del Fabbro M. Investigation on the shaping ability of nickel-titanium files when used with a reciprocating motion. J Endod 2011; 37: 1398-401
- 27 Bergmans L, Van Cleynenbreugel J, Wevers M, Lambrechts P. A methodology for quantitative evaluation of root canal instrumentation using microcomputed tomography. Int Endod J 2001; 34: 390-8
- 28 Garip Y, Günday M. The use of computed tomography when comparing nickel-titanium and stainless steel files during preparation of simulated curved canals. Int Endod J 2001; 34: 452-7
- 29 Peters OA. Current challenges and concepts in the preparation of root canal systems: A review. J Endod 2004; 30: 559-67
- 30 Peters OA, Laib A, Göhring TN, Barbakow F. Changes in root canal geometry after preparation assessed by high-resolution computed tomography. J Endod 2001; 27: 1-6
- 31 Schäfer E, Oitzinger M. Cutting efficiency of five different types of rotary nickel-titanium instruments. J Endod 2008; 34: 198-200
- 32 Setzer FC, Kwon TK, Karabucak B. Comparison of apical transportation between two rotary file systems and two hybrid rotary instrumentation sequences. J Endod 2010; 36: 1226-9
- 33 Gluskin AH, Brown DC, Buchanan LS. A reconstructed computerized tomographic comparison of Ni-Ti rotary GT files versus traditional instruments in canals shaped by novice operators. Int Endod J 2001; 34: 476-84
- 34 Zhao N, Chu JP, Yan B, Liu XJ. Cone-beam computed tomography analysis of the canal transportation after mechanical preparation with two different rotary nickel-titanium systems. Chin J Conserv Dent 2011; 21: 683-6
- 35 Bürklein S, Hinschitza K, Dammaschke T, Schäfer E. Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper. Int Endod J 2012; 45: 449-61
- 36 Kum KY, Spängberg L, Cha BY, Il-Young J, Msd. Seung-Jong L. et al. Shaping ability of three profile rotary instrumentation techniques in simulated resin root canals. J Endod 2000; 26: 719-23
- 37 Fayyad DM, Elhakim ElgendyAA. Cutting efficiency of twisted versus machined nickel-titanium endodontic files. J Endod 2011; 37: 1143-6
- 38 Freire LG, Gavini G, Branco-Barletta F, Sanches-Cunha R, dos Santos M. Microscopic computerized tomographic evaluation of root canal transportation prepared with twisted or ground nickel-titanium rotary instruments. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112: e143-8
- 39 Wu MK, Fan B, Wesselink PR. Leakage along apical root fillings in curved root canals. Part I: Effects of apical transportation on seal of root fillings. J Endod 2000; 26: 210-6