J Hand Microsurg 2014; 06(02): 74-84
DOI: 10.1007/s12593-014-0163-1
Review Article
Thieme Medical and Scientific Publishers Private Ltd.

A Systematic Review of Distal Interphalangeal Joint Arthrodesis

D.R. Dickson
,
S.S. Mehta
,
D. Nuttall
,
C.Y. Ng

Verantwortlicher Herausgeber dieser Rubrik:
Weitere Informationen

Publikationsverlauf

17. Juni 2014

13. Oktober 2014

Publikationsdatum:
13. September 2016 (online)

Abstract

Arthrodesis of the distal interphalangeal joint of the hand is a reliable procedure for creating a painless stable joint. Numerous techniques are described within the literature for varying indications. We undertook a systematic review of all studies published within the English literature to provide a comparison of the different techniques. The published studies were predominantly of Level IV evidence. The most commonly employed techniques were Kirschner wire, headless compression screw and cerclage wires. There was no difference in infection rates. Headless compression screws appear to have increased union rates but are associated with complications not seen with other well-established and cheaper techniques. The screw diameter is often similar to or larger than the joint itself, which can result in penetration. Furthermore, they limit the available angle for achieving fusion. Other than in terms of union, there is insufficient evidence to show the headless compression screw is superior to other techniques.

 
  • References

  • 1 Moberg E, Henrickson B. Technique for digital arthrodesis: a study of 150 cases. Acta Chir Scand 1960; 118: 331-338
  • 2 Pribyl CR, Omer Jr GR, McGinty L. Effectiveness of the chevron arthrodesis in small joints of the hand. J Hand Surg [Am] 1996; 21: 1052-1058
  • 3 Carroll RE, Hill NA. Small joint arthrodesis in hand reconstruction. J Bone Joint Surg 1969; 51: 1219-1221
  • 4 Lewis RC, Nordyke MD, Tenny JR. The tenon method of small joint arthrodesis in the hand. J Hand Surg [Am] 1986; 11: 567-569
  • 5 Bunnel S. Surgery of the hand. 2nd edn Philadelphia: J.B. Lippincott Co; 1948
  • 6 Von Saal FH. Intramedullary fixation in fractures of the hand and finger. JBJS 1953; 35A: 5
  • 7 Tupper JW. A compression arthrodesis device for small joints of the hands. Hand 1972; 4: 62-64
  • 8 Micks JE, Hager D. A compression apparatus for fusion of the hand joints. Med Trial Tech 1970; 16: 35-37
  • 9 Weber BG. Grundlagen und moglichkeiten der juggertungs osteosynthesis. Chirurgie 1964; 35: 81
  • 10 Muller G, Schoenberger F. Technik der compression arthrodese am finger mittels jug shraube. Handchirurgie 1970; 2: 218
  • 11 Faithfull DK, Herbert TJ. Small joint fusions of the hand using the Herbert bone screw. J Hand Surg (Br) 1984; 9: 167-168
  • 12 Konan S, Das A, Taylor E, Sorene E. Distal interphalangeal joint arthrodesis in extension using a headless compressive screw. Acta Ortho Belg 2013; 79: 154-158
  • 13 Song JH, Lee JY, Chung YG, Park IJ. Distal interphalangeal joint arthrodesis with a headless compression screw: morphometric and functional analyses. Arch Orthop Trauma Surg 2012; 132: 663-669 doi:10.1007/s00402-011-1413-3
  • 14 Brutus JP, Palmer AK, Mosher JF, Harley BJ, Loftus JB. Use of a headless compression screw for distal interphalangeal joint arthrodesis in digits: clinical outcome and review of complications. J Hand Surg 2006; 31A: 85-89
  • 15 Iwamoto T, Matsumura N, Sato K, Momohara S, Toyama Y, Nakamura T. An obliquely placed headless compression screw for distal interphalangeal joint arthrodesis. J Hand Surg [Am] 2013; 38A: 2360-2364 doi:10.1016/j.jhsa.2013.09.026
  • 16 Cox C, Earp BE, Floyd WE, Blazar PE. Arthrodesis of the thumb interphalangeal joint and finger distal interphalangeal joints with a headless compression screw. J Hand Surg [Am] 2014; 39: 24-28 doi: 10.1016/j.jhsa.2013.09.040
  • 17 Villani F, Uribe-Echevarria B, Vaienti L. Distal interphalangeal joint arthrodesis for degenerative osteoarthritis with compression screw: results in 102 digits. J Hand Surg [Am] 2012; 37A: 1330-1334 doi:10.1016/j.jhsa.2012.02.048
  • 18 Ruchelsman DE, Hazel A, Mudgal CS. Treatment of symptomatic distal interphalangeal joint arthritis with percutaneous arthrodesis: a novel technique in select patients. Hand 2010; 5: 434-439 doi: 10.1007/s11552-010-9265-9
  • 19 Matsumoto T, Nakamura I, Miura A, Momoyama G, Ito K. Distal interphalangeal joint arthrodesis with the reverse fix nail. J Hand Surg [Am] 2013; 38A: 1301-1306 doi:10.1016/j.jhsa.2013.01.017
  • 20 El-Hadidi S, Al-Kdah H. Distal interphalangeal joint arthrodesis with Herbert screw. Hand Surgery 2003; 8: 21-24
  • 21 Kocak E, Carruthers KH, Kobus RJ. Distal interphalangeal joint arthrodesis with the Herbert headless compression screw: outcomes and complications in 64 consecutively treated joints. Hand 2011; 5: 56-59 doi:10.1007/s11552-010-9295-3
  • 22 Lamas Gomez C, Proubasta I, Escriba I, Itarte J, Caceres E. Distal interphalangeal joint arthrodesis: treatment with Herbert screw. J South Orth Ass 2003; 12: 154-159
  • 23 Stern PJ, Fulton DB. Distal interphalangeal joint arthrodesis: an analysis of complications. J Hand Surg 1992; 17A: 1139-1145
  • 24 Engel J, Tsur H, Farin I. A comparison between K-wire and compression screw fixation after arthrodesis of the distal interphalangeal joint. Plast Recon Surg 1977; 60: 611-614
  • 25 Burton RI, Margles SW, Lunseth PA. Small-joint arthrodesis in the hand. J Hand Surg 1986; 11A: 678-682
  • 26 Olivier LC, Gensigk F, Board TN, Kendoff D, Krehmeier U, Wolfhard U. Arthrodesis of the distal interphalangeal joint: description of a new technique and clinical follow-up at 2 years. Arch Orthop Trauma Surg 2008; 128: 307-311
  • 27 Teoh LC, Yeo SJ, Singh I. Interphalangeal joint arthrodesis with oblique placement of an AO lag screw. J Hand Surg 1994; 19B: 208-211
  • 28 Mantovani G, Fukushima WY, Cho AB, Aita MA, Lino W, Nunes Faria F. Alternative to the distal interphalangeal joint arthrodesis: lateral approach and plate fixation. J Hand Surg [Am] 2008; 33A: 31-34 doi:10.1016/jjhsa.2007.09.004
  • 29 Shanker HK, Johnstone AJ, Rizzo L, Chesney RB. Pepper-pot arthrodesis of the small joints of the hand: our experience in 68 cases. J Hand Surg 2002; 27B: 430-432
  • 30 Lister G. Intraosseous wiring of the digital skeleton. J Hand Surg [Am] 1978; 5: 427-435
  • 31 Stahl S, Rozen N. Tension-band arthrodesis of the small joints of the hand. Orthopedics 2001; 24: 981-983
  • 32 Zavitsanos G, Watkins F, Britton E, Somia N, Gupta A, Kleinert H. Distal interphalangeal joint arthrodesis using intramedullary and interosseous fixation. Hand Surgery 1999; 4: 51-55
  • 33 Leonard MH, Capen DA. Compression arthrodesis of finger joints. Clinc Orth Rel Res 1979; 145: 193-198
  • 34 Seitz Jr WH, Sellman DC, Scarcella JB, Froimson AI. Compression arthrodesis of the small joints of the hand. Clin Orthop Rel Res 1994; 304: 116-121
  • 35 Wexler MR, Rousso M, Weinberg H. Arthrodesis of finger joints by dynamic external compression. Plast Recon Surg 1977; 59: 882-885
  • 36 Sabbagh W, Grobbelaar AO, Clarke C, Smith PJ, Harrison DH. Long-term results of distal arthrodesis with the Harrison-Nicolle peg. J Hand Surg 2001; 26B: 568-571
  • 37 Arata J, Ishikawa K, Soeda H, Kitayama T. Arthrodesis of the distal interphalangeal joint using a bioabsorbable rod as an intramedullary nail. Scan J Plast Recon 2003; 37: 228-231
  • 38 Harrison SH, Nicolle PV. A new intramedullary bone peg for digital arthrodesis. Br J Plast Surg 1974; 27: 240-241
  • 39 Faran K, Ichioka N, Trzeciak MA, Han S, Medige J, Moy OJ. Effect of bone quality on the forces generated by compressive screws. J Biomech 1999; 32: 861-864
  • 40 Mintalucci D, Lutsky KF, Matzon JL, Rivlin M, Niver G Beredjiklian Distal interphalangeal joint bony dimensions related to headless compression screw sizes. J Hand Surg [Am] 2014; 39: 1068-1074
  • 41 Wyrsch B, Dawson J, Weikert D, Milek M. Distal interphalangeal joint arthrodesis comparing tension band wire and Herbert screw: a biomechanical and dimensional analysis. J Hand Surg [Am] 1996; 21A: 438-443
  • 42 Hooper G. Techniques of interphalangeal arthrodesis. In: Bowers WH. The interphalangeal joints. Churchill Livingstone, UK: 1987: 174-180
  • 43 Katzman SS, Gibeault JD, Dickson K, Thompson JD. Use of a Herbert screw for interphalangeal joint arthrodesis. Clin Orth Rel Res 1993; 296: 127-132
  • 44 Straub LR. The rheumatoid hand. Clinical Orthopaedics 1959; 15: 127-139
  • 45 Tomaino MM. Distal interphalangeal joint arthrodesis with screw fixation: why and how. Hand Clin 2006; 22: 207-210