CC BY-NC-ND 4.0 · Rev Bras Ortop (Sao Paulo) 2019; 54(02): 190-197
DOI: 10.1016/j.rbo.2017.11.008
Original Article | Artigo Original
Sociedade Brasileira de Ortopedia e Traumatologia. Published by Thieme Revnter Publicações Ltda Rio de Janeiro, Brazil

Análise biomecânica da reconstrução do ligamento cruzado anterior[*]

Artikel in mehreren Sprachen: português | English
António Completo
1   Departamento de Engenharia Mecânica, Universidade de Aveiro, Aveiro, Portugal
,
José Carlos Noronha
2   Hospital da Ordem da Trindade, Porto, Portugal
,
Carlos Oliveira
1   Departamento de Engenharia Mecânica, Universidade de Aveiro, Aveiro, Portugal
,
Fernando Fonseca
3   Serviço de Ortopedia, Centro Hospitalar e Universitário de Coimbra, Coimbra, Portugal
4   Faculdade de Medicina, Universidade de Coimbra, Coimbra, Portugal
› Institutsangaben
Weitere Informationen

Publikationsverlauf

06. September 2017

28. November 2017

Publikationsdatum:
17. April 2019 (online)

Resumo

Objetivo A reconstrução do ligamento cruzado anterior é aconselhável sobretudo em atletas de alta demanda física. Diversas técnicas são usadas na reconstrução, mas a grande questão é qual o melhor posicionamento para o enxerto. Analisar o efeito biomecânico da posição dos túneis ósseos na repartição de carga e cinemática da articulação, bem como os resultados funcionais em médio prazo, após reconstrução do ligamento cruzado anterior.

Métodos Fez-se um estudo de simulação biomecânica computacional com modelos de elementos finitos do joelho original e com reconstrução do ligamento cruzado anterior (Neo-LCA) em quatro combinações de posição dos túneis ósseos (femoral central-tibial central, femoral anterior-tibial central, femoral posterossuperior-tibial anterior e femoral central-tibial anterior) com o mesmo tipo de enxerto. Para cada modelo, foram comparadas a pressão de contato na cartilagem, a rotação e translação do fêmur e dos meniscos e a deformação nos ligamentos.

Resultados Nenhum modelo de Neo-LCA foi capaz de reproduzir, na íntegra, o modelo do joelho original. Quando o túnel femoral era colocado em posição mais posterior, observaram-se pressões na cartilagem 25% mais baixas e translação dos meniscos superiores entre 12% e 30% relativamente ao modelo intacto. Quando o túnel femoral estava em posição mais anterior, observou-se uma rotação interna do fêmur 50% inferior ao modelo intacto.

Conclusão Os resultados evidenciam que uma localização do túnel femoral mais distante da posição central parece ser mais preponderante para um comportamento mais díspar relativamente à articulação intacta. Na posição mais anterior existe um aumento da instabilidade rotatória.

* Trabalho desenvolvido no Departamento de Engenharia Mecânica, Universidade de Aveiro, Aveiro, Portugal. Publicado originalmente por Elsevier Ltda.


 
  • References

  • 1 Carnes J, Stannus O, Cicuttini F, Ding C, Jones G. Knee cartilage defects in a sample of older adults: natural history, clinical significance and factors influencing change over 2.9 years. Osteoarthritis Cartilage 2012; 20 (12) 1541-1547
  • 2 Completo A, Fonseca F. Fundamentos de biomecânica musculoesquelética e ortopédica. Porto: Publindustria; 2011
  • 3 Erdemir A, Sibole S. A three-dimensional finite element representation of the knee joint. 2010. . In: User's Guide. Version 1.0.0
  • 4 Sibole S, Bennetts C, Maas S. Open knee: a 3 d finite element representation of the knee joint. In: 34th Annual Meeting of the American Society of Biomechanics, Providence, RI from Wednesday, August 18, 2010
  • 5 Noronha JC. Ligamento cruzado anterior [tese]. Porto: Instituto de Ciências Biomédicas Abel Salazar, Universidade do Porto; 2000
  • 6 Peña E, Calvo B, Martínez MA, Doblaré M. A three-dimensional finite element analysis of the combined behavior of ligaments and menisci in the healthy human knee joint. J Biomech 2006; 39 (09) 1686-1701
  • 7 Rho JY, Ashman RB, Turner CH. Young's modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements. J Biomech 1993; 26 (02) 111-119
  • 8 Donahue TL, Hull ML, Rashid MM, Jacobs CR. A finite element model of the human knee joint for the study of tibio-femoral contact. J Biomech Eng 2002; 124 (03) 273-280
  • 9 Butler DL, Guan Y, Kay MD, Cummings JF, Feder SM, Levy MS. Location-dependent variations in the material properties of the anterior cruciate ligament. J Biomech 1992; 25 (05) 511-518
  • 10 Harner CD, Xerogeanes JW, Livesay GA, Carlin GJ, Smith BA, Kusayama T. , et al. The human posterior cruciate ligament complex: an interdisciplinary study. Ligament morphology and biomechanical evaluation. Am J Sports Med 1995; 23 (06) 736-745
  • 11 Quapp KM, Weiss JA. Material characterization of human medial collateral ligament. J Biomech Eng 1998; 120 (06) 757-763
  • 12 Shani RH, Umpierez E, Nasert M, Hiza EA, Xerogeanes J. Biomechanical comparison of quadriceps and patellar tendon grafts in anterior cruciate ligament reconstruction. Arthroscopy 2016; 32 (01) 71-75
  • 13 Bergmann G, Bender A, Graichen F, Dymke J, Rohlmann A, Trepczynski A. , et al. Standardized loads acting in knee implants. PLoS One 2014; 9 (01) e86035
  • 14 Morrison JB. The mechanics of the knee joint in relation to normal walking. J Biomech 1970; 3 (01) 51-61
  • 15 Van Rossom S, Smith CR, Zevenbergen L, Thelen DG, Vanwanseele B, Van Assche D. , et al. Knee Cartilage Thickness, T1ρ and T2 Relaxation Time Are Related to Articular Cartilage Loading in Healthy Adults. PLoS One 2017; 12 (01) e0170002
  • 16 Liu F, Kozanek M, Hosseini A, Van de Velde SK, Gill TJ, Rubash HE. , et al. In vivo tibiofemoral cartilage deformation during the stance phase of gait. J Biomech 2010; 43 (04) 658-665
  • 17 Vedi V, Williams A, Tennant SJ, Spouse E, Hunt DM, Gedroyc WM. Meniscal movement. An in-vivo study using dynamic MRI. J Bone Joint Surg Br 1999; 81 (01) 37-41
  • 18 Matsumoto H, Seedhom BB, Suda Y, Otani T, Fujikawa K. Axis location of tibial rotation and its change with flexion angle. Clin Orthop Relat Res 2000; (371) 178-182
  • 19 Khalfayan EE, Sharkey PF, Alexander AH, Bruckner JD, Bynum EB. The relationship between tunnel placement and clinical results after anterior cruciate ligament reconstruction. Am J Sports Med 1996; 24 (03) 335-341
  • 20 Shelbourne KD, Gray T. Minimum 10-year results after anterior cruciate ligament reconstruction: how the loss of normal knee motion compounds other factors related to the development of osteoarthritis after surgery. Am J Sports Med 2009; 37 (03) 471-480
  • 21 Shelbourne KD, Benner RW, Gray T. Results of after anterior cruciate ligament reconstruction with patellar tendon autografts: objective factors associated with thw development of osteoarthritis at 20 to 33 years after surgery. Am J Sports Med 2017; 45 (12) 2730-2738