Endoscopy 2018; 50(09): E269-E271
DOI: 10.1055/a-0640-2817
E-Videos
© Georg Thieme Verlag KG Stuttgart · New York

Successful endoscopic lithotripsy using a new digital cholangioscope through an overtube placed by an enteroscope

Ryunosuke Hakuta
Department of Gastroenterology, Graduate School of Medicine, University of Tokyo, Tokyo, Japan
,
Hirofumi Kogure
Department of Gastroenterology, Graduate School of Medicine, University of Tokyo, Tokyo, Japan
,
Yousuke Nakai
Department of Gastroenterology, Graduate School of Medicine, University of Tokyo, Tokyo, Japan
,
Atsuo Yamada
Department of Gastroenterology, Graduate School of Medicine, University of Tokyo, Tokyo, Japan
,
Naminatsu Takahara
Department of Gastroenterology, Graduate School of Medicine, University of Tokyo, Tokyo, Japan
,
Suguru Mizuno
Department of Gastroenterology, Graduate School of Medicine, University of Tokyo, Tokyo, Japan
,
Kazuhiko Koike
Department of Gastroenterology, Graduate School of Medicine, University of Tokyo, Tokyo, Japan
› Author Affiliations
Further Information

Publication History

Publication Date:
03 July 2018 (online)

A 29-year-old woman who had undergone extrahepatic bile duct resection and hepaticojejunostomy for congenital biliary dilation was admitted to our hospital with cholangitis. Magnetic resonance cholangiopancreatography revealed multiple large intrahepatic bile duct stones ([Fig. 1]). Most of the stones were fragmented and removed by extracorporeal shock wave lithotripsy and endoscopic mechanical lithotripsy (LithoCrush V; Olympus, Tokyo, Japan) during double-balloon endoscope-assisted endoscopic retrograde cholangiopancreatography (EI-580BT; Fujifilm, Tokyo, Japan). However, intrahepatic stones in the right posterior branch could not be removed owing to the acute angle of the duct ([Fig. 2]). To perform intraductal lithotripsy under direct visualization, the enteroscope was withdrawn while leaving the overtube in situ. The direct cholangioscope (SpyGlass DS Direct Visualization System; Boston Scientific Japan, Tokyo, Japan) was successfully advanced through the overtube into the right posterior branch. The intrahepatic stones were visualized ([Fig. 3]) and successfully fragmented by electrohydraulic lithotripsy using the Autolith EHL system and 1.9-Fr probe (Boston Scientific Japan). Finally, the cholangioscope was exchanged for the enteroscope, and fragmented stones were extracted using a balloon catheter ([Fig. 4], [Video 1]).

Zoom Image
Fig. 1 Magnetic resonance cholangiopancreatography revealed multiple large intrahepatic bile duct stones (arrows).
Zoom Image
Fig. 2 Endoscopic mechanical lithotripsy and extracorporeal shock wave lithotripsy fragmented the stones. Intrahepatic bile duct stones in the right posterior branch (arrow) could not be removed due to the acute angle of the duct.
Zoom Image
Fig. 3 Cholangioscopic view of bile duct stone in the right posterior branch.
Zoom Image
Fig. 4 Complete stone removal in the right posterior branch was confirmed by cholangiogram using a balloon catheter (a) and computed tomography (b).

Video 1 The cholangioscope was successfully advanced into the right posterior branch through the overtube. The intrahepatic bile duct stones were fragmented using electrohydraulic lithotripsy under direct visualization.


Quality:

Endoscopic removal of large bile duct stones remains challenging, especially in cases with surgically altered anatomy [1] [2]. Direct insertion of an enteroscope is possible in cases with a large bile duct [3] [4] [5], though this technique cannot be utilized in cases with intrahepatic stones in small bile ducts. To our knowledge, this is the first report of successful endoscopic treatment of intrahepatic bile duct stones under direct cholangioscopy in a patient with surgically altered anatomy. Although scope exchange to a direct cholangioscope through the overtube is technically possible only when the overtube is completely straight, without any loops, as in our case ([Fig. 5]), this new method is an additional option for the management of intrahepatic bile duct stones after hepaticojejunostomy.

Zoom Image
Fig. 5 The enteroscope and overtube were completely straight without any loops.

Endoscopy_UCTN_Code_TTT_1AR_2AH

Endoscopy E-Videos
https://eref.thieme.de/e-videos

Endoscopy E-Videos is a free access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online.
This section has its own submission website at https://mc.manuscriptcentral.com/e-videos

 
  • References

  • 1 Oana S, Shibata S, Matsuda N. et al. Efficacy and safety of double-balloon endoscopy-assisted endoscopic papillary large-balloon dilatation for common bile duct stone removal. Dig Liver Dis 2015; 47: 401-404
  • 2 Shimatani M, Takaoka M, Okazaki K. Tips for endoscopic stone extraction using new short-type double balloon endoscope for common bile duct stones in patients with surgically altered gastrointestinal anatomy. Dig Endosc 2018; 30: 130-131
  • 3 Hakuta R, Kogure H, Isayama H. et al. Electrohydraulic lithotripsy as a salvage option for stone impaction during double-balloon endoscope-assisted ERCP. Gastrointest Endosc 2016; 84: 177
  • 4 Hakuta R, Kogure H, Isayama H. et al. Electrohydraulic lithotripsy of large bile duct stones under direct cholangioscopy with a double-balloon endoscope. Endoscopy 2015; 47 (Suppl. 01) E519-E520
  • 5 Yamauchi H, Kida M, Miyazawa S. et al. Electrohydraulic lithotripsy under peroral direct cholangioscopy using short-type single-balloon enteroscopy for large common bile duct stone in patients with Roux-en-Y gastrectomy. Endoscopy 2015; 47 (Suppl. 01) E240-E241