Management of CPAP-Induced Ocular Air Reflux Due to a Porous Polyethylene-Coated Lester Jones Tube

Behandlung von CPAP-induziertem Air-Reflux aufgrund eines Porous-Polyethylene-Coated-Lester-Jones-Tubes
Ivan O. Haefliger
1   Oculoplastic Surgery, Holbein PraxisKlinik, Basel, Switzerland
2   School of Medicine, University of Basel, Basel, Switzerland
,
Maurice Desmaris
1   Oculoplastic Surgery, Holbein PraxisKlinik, Basel, Switzerland
,
Ana Rosa Pimentel de Figueiredo
3   Department of Oculoplastic Surgery, Hospital Sao Geraldo, Universidade Federal de Minas Gerais Faculdade de Medicina, Belo Horizonte, Brazil
› Institutsangaben
Weitere Informationen

Publikationsverlauf

received 19. September 2018

accepted 06. November 2018

Publikationsdatum:
18. April 2019 (online)

Background

Continuous positive airway pressure (CPAP) is a common treatment for obstructive sleep apnea, in which a CPAP machine delivers, through a mask, a positive pressure in the airway to prevent them from collapsing during sleep. Under CPAP, ocular air reflux (air regurgitation) can occur in patients who had a conjunctivo-dacryocystorhinostomy [1], a lacrimal drainage surgical procedure in which a tears drainage tube (i.e., Lester-Jones tube) drains tears from the surface of the eye into the nasal cavity. Some Lester-Jones tubes are externally covered with a porous structure, porous polyethylene (Medpor®, Porex Surgical Inc., Newnan, GA, USA), allowing this material to imbed itself in the surrounding tissue. Medpor®-coated Lester-Jones tubes have the advantage to be more stable but have the disadvantage that, sometimes, it can be very difficult or even almost impossible to remove or reposition them.

The present paper appears to be the first report made in the literature of CPAP-induced ocular air reflux in the case of a nonremovable Medpor®-coated tears drainage tube as well as the management of CPAP-induced ocular air reflux using a “finger-like” external compression bandage.

 
  • References

  • 1 Cannon PS, Madge SN, Selva D. Air regurgitation in patients on continuous positive airway pressure (CPAP) therapy following dacrocystorhinostomy with or without Lester-Jones tube insertion. Br J Ophthalmol 2010; 94: 891-893
  • 2 Servat JJ, Black EH, Gladstone GJ. A solution to the Jones tube continuous positive airway pressure (CPAP) dilemma?. Ophthal Plast Reconstr Surg 2012; 28: 151-152
  • 3 Goldberg DS. Management of air regurgitation through a Jones tube in a patient using continuous positive airway pressure. Ophthal Plast Reconstr Surg 2011; 27: 76-77
  • 4 Longmire MR, Carter KD, Allen RC. Intolerance of jones tube placement in a patient using continuous positive airway pressure. Ophthal Plast Reconstr Surg 2010; 26: 68-69
  • 5 Harrison W, Pence N, Kovacich S. Anterior segment complications secondary to continuous positive airway pressure machine treatment in patients with obstructive sleep apnea. Optometry 2007; 78: 352-355
  • 6 Hayirci E, Yagci A, Palamar M. et al. The effect of continuous positive airway pressure treatment for obstructive sleep apnea syndrome on the ocular surface. Cornea 2012; 31: 604-608
  • 7 Vicinanzo MG, Allamneni C, Compton CJ. et al. The Prevalence of Air Regurgitation and its Consequences after Conjunctivodacryocystorhinostomy and Dacryocystorhinostomy in Continuous Positive Airway Pressure Patients. Ophthal Plast Reconstr Surg 2015; 31: 269-271