Retrospective Comparative Study of the Influence on Quality of Primary Total Hip Arthroplasty by the EndoCert-Certification System in a Communal Hospital
Artikel in mehreren Sprachen: English | deutschAbstract
The EndoCert®-Initiative system sets specific requirements for the structural, process and result quality in certified Arthroplasty Centers in Germany. However, it remains unclear to what extent the certification process can increase the quality in total hip and knee arthroplasty. Aim of the comparative retrospective study is to analyse the change in quality of total hip arthroplasty in a communal hospital before and after the certification process. All primary total hip arthroplasties (n = 366) between 2013 and 2016 were included in the study retrospectively and grouped by treatment period. Treatment was performed in group 1 without clinical pathways, in group 2 pathway-controlled without a valid certificate and in group 3 pathway-controlled after final completion of the certification process. Outcome quality was analysed using quality indicators defined by the EndoCert-Initiative and further predefined indicators. Results show quality improvement under certified pathway-controlled treatment, e.g. time of surgery, cup and stem positioning, blood transfusion rate, periprosthetic fractures. However, improvements were not significantly in all cases and limitations must be recognized. Positive effects of the certification process legitimate capital investment and efforts. Further quality indicators may be implemented in the certification process to improve quality of treatment in arthroplasty.
Key words
total hip arthroplasty - outcome and process assessment - clinical pathways - certificationPublikationsverlauf
Artikel online veröffentlicht:
04. März 2020
© 2020. Thieme. All rights reserved.
Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany
-
References/Literatur
- 1 Bleß HH, Kip M. Hrsg. Weißbuch Gelenkersatz. Versorgungssituation endoprothetischer Hüft- und Knieoperationen in Deutschland. Heidelberg, Berlin: Springer; 2016
- 2 Grimberg A, Jansson V, Liebs T. et al. Endoprothesenregister Deutschland (EPRD) – Jahresbericht 2017. Im Internet (Stand:24.10.2019): https://www.eprd.de/fileadmin/user_upload/Dateien/Publikationen/Berichte/EPRD-Jahresbericht_2017_Einzelseiten_Online-Version.pdf
- 3 Haas H, Mittelmeier W. Die Einführung des EndoCert-Systems zur Zertifizierung von Endoprothesenzentren – Erfahrungen aus der Pilotphase. Orthopäde 2014; 43: 534-540 doi:10.1007/s00132-014-2294-2
- 4 Lau TW, Fang C, Leung F. Assessment of postoperative short-term and long-term mortality risk in Chinese geriatric patients for hip fracture using Charlson comorbidity score. Hong Kong Med J 2016; 22: 16-22 doi:10.12809/hkmj154451
- 5 Lindahl H. Epidemiology of periprosthetic femur fracture around a total hip arthroplasty. Injury 2007; 38: 651-654 doi:10.1016/j.injury.2007.02.048
- 6 Helse Bergen HF. Norwegian National Advisory Unit on Arthroplasty and Hip Fractures – Report June 2017. Im Internet (Stand: 24.10.>2019): http://nrlweb.ihelse.net/eng/Rapporter/Report2017_english.pdf
- 7 Kärrholm J, Lindahl H, Malchau H. et al. The Swedish Hip Arthroplasty Register. Annual Report 2016. Im Internet (Stand: 24.10.2019): https://registercentrum.blob.core.windows.net/shpr/r/Annual-Report-2016-B1eWEH-mHM.pdf
- 8 Del Schutte jr. H, Lipman AJ, Bannar SM. et al. Effects of acetabular abduction on cup wear rates in total hip arthroplasty. J Arthroplasty 1998; 13: 621-626 doi:10.1016/s0883-5403(98)80003-x
- 9 Jolles BM, Zangger P, Leyvraz PF. Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis. J Arthroplasty 2002; 17: 282-288 doi:10.1054/arth.2002.30286
- 10 Loitsch T, Freitag T, Leucht F. et al. Die Pfanneninklinationsmessung in der Beckenübersichtsaufnahme: Ein Qualitätsindikator nach Hüft-TEP Primärimplantation?. Orthopäde 2018; 47: 1003-1008 doi:10.1007/s00132-018-3628-2
- 11 Esposito CI, Gladnick BP, Lee YY. et al. Cup position alone does not predict risk of dislocation after hip arthroplasty. J Arthroplasty 2015; 30: 109-113 doi:10.1016/j.arth.2014.07.009
- 12 Doria C, De Santis V, Falcone G. et al. Osseointegration in hip prostheses: experimental study in sheep. Int Orthop 2003; 27: 272-277 doi:10.1007/s00264-003-0474-5
- 13 Evola FR, Evola G, Graceffa A. et al. Performance of the CLS Spotorno uncemented stem in the third decade after implantation. Bone Joint J 2014; 96-B: 455-461 doi:10.1302/0301-620X.96B4.32607
- 14 Shishido T, Tateiwa T, Takahashi Y. et al. Effect of stem alignment on long-term outcomes of total hip arthroplasty with cementless Bi-Metric femoral components. J Orthop 2018; 15: 134-137 doi:10.1016/j.jor.2018.01.008
- 15 Zang J, Uchiyama K, Moriya M. et al. Long-term clinical and radiographic results of the cementless Spotorno stem in Japanese patients: a more than 15-year follow-up. J Orthop Surg (Hong Kong) 2018; 26: 2309499017750310 doi:10.1177/2309499017750310
- 16 Holzer LA, Scholler G, Wagner S. et al. The accuracy of digital templating in uncemented total hip arthroplasty. Arch Orthop Trauma Surg 2019; 139: 263-268 doi:10.1007/s00402-018-3080-0
- 17 Heinert G, Hendricks J, Loeffler MD. Digital templating in hip replacement with and without radiological markers. J Bone Joint Surg B 2009; 91-B: 459-462 doi:10.1302/0301-620X.91B4.21730
- 18 Kim YH, Kim VE. Uncemented porous-coated anatomic total hip replacement: results at 6 years in a consecutive series. J Bone Joint Surg Br 1993; 75: 6-13
- 19 Stigler SK, Müller FJ, Pfaud S. et al. Digital templating in total hip arthroplasty: additional anteroposterior hip view increases the accuracy. World J Orthop 2017; 8: 30-35 doi:10.5312/wjo.v8.i1.30
- 20 Unnanuntana A, Wagner D, Goodman SB. The accuracy of preoperative templating in cementless total hip arthroplasty. J Arthroplasty 2009; 24: 180-186 doi:10.1016/j.arth.2007.10.032
- 21 Cho MR, Jun CM, Choi WK. Preoperative temporary discontinuation of aspirin medication does not increase the allogenic transfusion rate and blood loss in primary total hip arthroplasty. Hip Pelvis 2019; 31: 82-86 doi:10.5371/hp.2019.31.2.82
- 22 Kyriakopoulos G, Oikonomou L, Panagopoulos A. et al. Transfusion rate, hospital stay and cost-effectiveness of intravenous or local administration of tranexamic acid in total hip and knee arthroplasty: a single-center randomized controlled clinical study. Orthop Rev (Pavia) 2019; 11: 7866 doi:10.4081/or.2019.7866
- 23 Hart A, Khalil JA, Carli A. et al. Blood transfusion in primary total hip and knee arthroplasty. Incidence, risk factors, and thirty-day complication rates. J Bone Joint Surg Am 2014; 96: 1945-1951 doi:10.2106/JBJS.N.00077
- 24 Zenk K, Finze S, Kluess D. et al. [Influence of surgeon experience in total hip arthroplasty. Dependence on operation time and complication risk]. Orthopade 2014; 43: 522-528 doi:10.1007/s00132-014-2292-4
- 25 Van Den Eeden Y, Van Den Eeden F. Learning curve of direct anterior total hip arthroplasty: a single surgeon experience. Acta Orthop Belg 2018; 84: 321-330
- 26 Osmanski-Zenk K, Finze S, Lenz R. et al. Influence of training of orthopaedic surgeons on clinical outcome after total hip arthroplasty in a high volume endoprosthetic centre. Z Orthop Unfall 2019; 157: 48-53 doi:10.1055/a-0627-7586
- 27 Bohl DD, Sershon RA, Fillingham YA. et al. Incidence, risk factors, and sources of sepsis following total joint arthroplasty. J Arthroplasty 2016; 31: 2875-2879 doi:10.1016/j.arth.2016.05.031
- 28 Barbieri A, Vanhaecht K, Van Herck P. et al. Effects of clinical pathways in the joint replacement: a meta-analysis. BMC Med 2009; 1: 32 doi:10.1186/1741-7015-7-32
- 29 den Hartog YM, Mathijssen NM, Hannink G. et al. Which patient characteristics influence length of hospital stay after primary total hip arthroplasty in a ‘fast-track’ setting?. Bone Joint J 2015; 97-B: 13-23 doi:10.1302/0301-620X.97B1.33886
- 30 von Lewinski G, Floerkemeier T, Budde S. et al. [Experience in establishing a certified endoprosthesis center]. Orthopade 2015; 44: 193-202 doi:10.1007/s00132-014-3022-7
- 31 Weber P, Paulus AC, Hallmen D. et al. [Does the certification according to EndoCert lead to a better quality of treatment?]. Orthopade 2017; 46: 78-84 doi:10.1007/s00132-016-3356-4