Endoscopy 2020; 52(09): E330-E332
DOI: 10.1055/a-1122-8350
E-Videos

Novel side-by-side metal stent placement for recurrent hepatic hilar obstruction after placement of multiple metal stents

Yoshikuni Nagashio
1   Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
,
Susumu Hijioka
1   Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
,
Yuya Kanai
2   Department of Radiological Technology, National Cancer Center Hospital, Tokyo, Japan
,
Akihiro Ohba
1   Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
,
Yuta Maruki
1   Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
,
Takuji Okusaka
1   Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan
,
Yutaka Saito
3   Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan
› Institutsangaben

Endoscopic re-intervention following placement of multiple self-expandable metal stents (SEMSs) is challenging [1] [2] [3]. A suitable re-intervention for malignant hilar biliary obstruction (MHBO) is not available. Plastic stents are used for re-intervention following placement of multiple SEMSs, but advancing the plastic stents through the mesh of the SEMS is difficult. This report describes successful side-by-side (SBS) metal stent deployment for recurrent MHBO after placement of SEMSs.

A 69-year-old man underwent endoscopic multistent drainage (8 mm × 8 cm and 8 mm × 6 cm; BileRush Selective; Piolax, Kanagawa, Japan) using a partial stent-in-stent (SIS) technique for MHBO due to a recurrent lesion after left lobectomy for left intrahepatic cholangiocarcinoma ([Fig. 1]). His obstructive jaundice recurred 7 months later. A contrast-enhanced computed tomography (CT) scan ([Fig. 2]) and endoscopic retrograde cholangiography (ERC) ([Fig. 3 a]) revealed recurrent hilar obstruction due to tumor ingrowth and overgrowth.

Zoom Image
Fig. 1 Endoscopic images of the initial drainage by partial stent-in-stent technique showing: a two 0.025-inch guidewires inserted into the dilated anterior and posterior branches: b the second uncovered self-expandable metal stent (SEMS; 8 mm × 6 cm) being placed into the anterior branch through the mesh of the first uncovered SEMS (8 mm × 8 cm) that had been placed in the posterior branch; c appearance after placement of the two stents.
Zoom Image
Fig. 2 Abdominal contrast-enhanced computed tomography scan showing recurrent hilar obstruction due to tumor ingrowth into the stent with dilatation of: a the anterior branch; b the posterior branch.
Zoom Image
Fig. 3 Endoscopic retrograde cholangiopancreatography images of simultaneous side-by-side self-expandable metal stent (SEMS) placement as re-intervention for occluded SEMSs showing: a recurrent hilar obstruction due to tumor ingrowth and overgrowth; b the two delivery systems for the 8-mm × 8-cm uncovered SEMSs that were inserted simultaneously over the guidewires; c, d the two SEMSs after their simultaneous deployment.

Endoscopic re-intervention was performed. Two 0.025-inch guidewires (VisiGlide 2; Olympus, Tokyo, Japan) were inserted into the dilated anterior and posterior branches, and two laser-cut SEMSs (8 mm × 8 cm; BileRush Selective; Piolax) with 5.7-Fr delivery systems were simultaneously inserted over the guidewires without balloon dilation of the stent mesh ([Fig. 3 b]; [Video 1]). The stents were then deployed in the optimal positions using the SBS technique ([Fig. 3 c, d]). [Fig. 4] shows the post-insertion CT images. His total bilirubin level improved from 4.4 mg/dL to 1.7 mg/dL within 14 days. Three months later, he succumbed to underlying disease but without experiencing occlusion of the SEMSs.

Video 1 Simultaneous side-by-side self-expandable metal stent (SEMS) placement as re-intervention for occlusion of SEMSs previously placed using the stent-in-stent technique.


Qualität:
Zoom Image
Fig. 4 Computed tomography (CT) scan images after simultaneous endoscopic side-by-side (SBS) placement of two uncovered self-expandable metal stents (SEMSs) showing: a the SEMSs in the anterior and posterior segments; b the SBS SEMSs (yellow arrows); c a reconstructed CT image of the SBS SEMSs (yellow arrows) positioned in the SEMSs previously deployed using the stent-in-stent technique.

Re-intervention using SBS placement of metal stents has two advantages over plastic stents. First, the thin SEMS delivery systems are simpler to advance and track, and easily penetrate the mesh for stent deployment. Second, SEMSs have longer patency than plastic stents [1].

This is the first report of the placement of simultaneous SBS SEMSs for re-intervention in recurrent MHBO following placement of multiple SEMSs. This innovative, efficacious method may be considered after the placement of multiple SEMSs.

Endoscopy_UCTN_Code_TTT_1AR_2AZ

Endoscopy E-Videos
https://eref.thieme.de/e-videos

Endoscopy E-Videos is a free access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high
quality video and all contributions are
freely accessible online.

This section has its own submission
website at
https://mc.manuscriptcentral.com/e-videos



Publikationsverlauf

Artikel online veröffentlicht:
04. März 2020

© Georg Thieme Verlag KG
Stuttgart · New York

 
  • References

  • 1 Inoue T, Naitoh I, Okamura F. et al. Reintervention for stent occlusion after bilateral self-expandable metallic stent placement for malignant hilar biliary obstruction. Dig Endosc 2016; 28: 731-737
  • 2 Okuno M, Mukai T, Iwashita T. et al. Evaluation of endoscopic reintervention for self-expandable metallic stent obstruction after stent-in-stent placement for malignant hilar biliary obstruction. J Hepatobiliary Pancreat Sci 2019; 26: 211-218
  • 3 Kawakami H, Itoi T, Kuwatani M. et al. Technical tips and troubleshooting of endoscopic biliary drainage for unresectable malignant hilar biliary obstruction. J Hepatobiliary Pancreat Sci 2015; 22: E12-E21