Eine quantitativ-anatomische Studie zur Plattenschraubenfixierung der hinteren Hüftgelenkpfannensäule durch einen posterioren AnsatzAbstract
Objective The aim of this study was to determine safe paths for screw placement on the posterior column of the acetabulum.
Methods A total of 25 male hemipelvises were utilized in this study. These hemipelvises were sectioned, and formed cross-sections A, B, C, D, and E. The length of the screw and screw posterior column angle of the entry points at cross-sections B, C, and D were measured.
Results On the margin of the acetabulum, lateral middle 1/4 point, midpoint, medial middle 1/4 point, and medial margin of the posterior column of each cross-section, the safe entry angle of inclination is 39, 57, 74, 90, and 106°, respectively, and the length of the screw is 35.5 mm, 33 mm, 32 mm, 31 mm, and 74 mm, respectively.
Conclusion On the lateral 1/4 region, lateral middle 1/4 region, medial middle 1/4 region, and medial 1/4 region of the posterior column, the screw posterior column angle is 40 ~ 60°, 60 ~ 75°, 75 ~ 90°, and 90°~parallel to the quadrilateral plate, respectively, and the length of the screw is 30 mm.
Zusammenfassung
Ziel Ziel dieser Studie ist es, sichere Wege für die Platzierung von Schrauben an der hinteren Säule des Acetabulums zu bestimmen.
Methoden In dieser Studie wurden insgesamt 25 männliche Hemipelvise verwendet. Diese Hemipelvise wurden geschnitten und bildeten Querschnitte A, B, C, D bzw. E. Die Länge der Schraube und der Winkel zwischen Schraube und hinterer Säule der Eintrittspunkte in den Querschnitten B, C und D wurden gemessen.
Ergebnisse Am Rand des Acetabulums, am lateralen mittleren 1/4 Punkt, am Mittelpunkt, am medialen mittleren 1/4 Punkt und am medialen Rand der hinteren Säule jedes Querschnitts beträgt der sichere Eintrittsneigungswinkel 39 °, 57 °, 74°90 ° bzw. 106 ° beträgt die Länge der Schraube 35,5 mm, 33 mm, 32 mm, 31 mm bzw. 74 mm.
Schlussfolgerung Im lateralen 1/4 Bereich, im lateralen mittleren 1/4 Bereich, im medialen mittleren 1/4 Bereich und im medialen 1/4 Bereich der hinteren Säule beträgt der Winkel der hinteren Säule der Schraube 40°~60°, 60°~75°, 75°~90° und 90°~parallel zur viereckigen Platte beträgt die Länge der Schraube 30 mm.
Publikationsverlauf
Artikel online veröffentlicht:
03. August 2020
© 2020. Thieme. All rights reserved.
Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany
-
References
- 1 Gänsslen A, Steinke B, Krettek C. Internal fixation of acetabular posterior wall fractures. Oper Orthop Traumatol 2009; 21: 283-295 doi:10.1007/s00064-009-1805-5
- 2 Bosse MJ. Posterior acetabular wall fractures: a technique for screw placement. J Orthop Trauma 1991; 5: 167-172 doi:10.1097/00005131-199105020-00008
- 3 Ebrahiem NA, Waldrop J, Yeasting RA. et al. Danger zone of the acetabulum. J Orthop Trauma 1992; 6: 146-151
- 4 Wu X, Chen W, Zhang Q. et al. The study of plate-screw fixation in the posterior wall of acetabulum using computed tomography images. J Trauma 2010; 69: 423-431 doi:10.1097/TA.0b013e3181ca05f6
- 5 Ebraheim NA, Savolaine ER, Hoeflinger MJ. et al. Radiological diagnosis of screw penetration of the hip joint in acetabular fracture reconstruction. J Orthop Trauma 1989; 3: 196-201 doi:10.1097/00005131-198909000-00003
- 6 Wang XQ, Cai JF, Cao XC. et al. A quantitative anatomic study of plate-screw fixation of the acetabular anterior column through an anterior approach. Arch Orthop Trauma Surg 2010; 130: 257-262
- 7 Schopfer A, Willett K, Powell J. et al. Cerclage wiring in internal fixation of acetabular fractures. J Orthop Trauma 1993; 7: 236-241
- 8 Anglen JO, DiPasquale T. The reliability of detecting screw penetration of the acetabulum by intraoperative auscultation. J Orthop Trauma 1994; 8: 404-408
- 9 Tile M, Helfet D, Kellam J. Fractures of the pelvis and acetabulum. 3rd ed.. Philadelphia: Lippincott Williams & Wilkins; 2003
- 10 Letournel E, Judet R. Fractures of the acetabulum. Berlin, Heidelberg: Springer; 1981