Subscribe to RSS
DOI: 10.1055/a-1369-8610
A comparison between 25-gauge and 22-gauge Franseen needles for endoscopic ultrasound-guided sampling of pancreatic and peripancreatic masses: a randomized non-inferiority study
http://dx.doi.org/10.13039/100008497Trial Registration: Clinical Research Information Service, Republic of Korea (https://cris.nih.go.kr/cris/en) Registration number (trial ID): KCT0003834 Type of study: Prospective parallel-group randomized non-inferiority trial
Abstract
Background Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) and fine-needle biopsy (FNB) are the current standard of care for sampling pancreatic and peripancreatic masses. Recently, a 22G EUS-FNB needle with Franseen geometry was developed, and this device was also introduced in a 25G platform. We compared the performance of the 25G and 22G Franseen needles for EUS-guided sampling of pancreatic and peripancreatic solid masses.
Methods We conducted a parallel-group randomized non-inferiority trial at a tertiary-care center from November 2018 to May 2019. The primary outcome was the quality of the histologic core assessed using the Gerke score. The optimal histologic core is indicated by a Gerke score of 4 or 5, which enables optimal histologic interpretation. The overall diagnostic accuracy and adverse event rate were also evaluated.
Results 140 patients were enrolled and randomized (1:1) to the 25G and 22G groups. Tissue acquisition by EUS-FNB was successful in all patients. The optimal histologic core procurement rate was 87.1 % (61/70) for the 25G needle vs. 97.1 % (68/70) for the 22G; difference −10 % (95 % confidence interval −17.35 % to −2.65 %). High quality specimens were more frequently obtained in the 22G group than in the 25G group (70.0 % [49/70] vs. 28.6 % [20 /70], respectively; P < 0.001). The overall diagnostic accuracy did not differ between the groups (97.4 % for 25G vs. 100 % for 22G).
Conclusions The 25G Franseen needle was inferior to the 22G needle in histologic core procurement. Therefore, for cases in which tissue architecture is pivotal for diagnosis, a 22G needle, which procures relatively higher quality specimens than the 25G needle, should be used.
Publication History
Received: 09 June 2020
Accepted: 11 January 2021
Article published online:
02 March 2021
© 2021. Thieme. All rights reserved.
Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany
-
References
- 1 Bang JY, Hebert-Magee S, Trevino J. et al. Randomized trial comparing the 22-gauge aspiration and 22-gauge biopsy needles for EUS-guided sampling of solid pancreatic mass lesions. Gastrointest Endosc 2012; 76: 321-327
- 2 Facciorusso A, Wani S, Triantafyllou K. et al. Comparative accuracy of needle sizes and designs for EUS tissue sampling of solid pancreatic masses: a network meta-analysis. Gastrointest Endosc 2019; 90: 893-903
- 3 Klapman JB, Logrono R, Dye CE. et al. Clinical impact of on-site cytopathology interpretation on endoscopic ultrasound-guided fine needle aspiration. Am J Gastroenterol 2003; 98: 1289-1294
- 4 Yasuda I, Goto N, Tsurumi H. et al. Endoscopic ultrasound-guided fine needle aspiration biopsy for diagnosis of lymphoproliferative disorders: feasibility of immunohistological, flow cytometric, and cytogenetic assessments. Am J Gastroenterol 2012; 107: 397-404
- 5 Witt BL, Adler DG, Hilden K. et al. A comparative needle study: EUS-FNA procedures using the HD ProCore™ and EchoTip® 22-gauge needle types. Diagn Cytopathol 2013; 41: 1069-1074
- 6 Kandel P, Tranesh G, Nassar A. et al. EUS-guided fine needle biopsy sampling using a novel fork-tip needle: a case-control study. Gastrointest Endosc 2016; 84: 1034-1039
- 7 Bang JY, Hebert-Magee S, Navaneethan U. et al. Randomized trial comparing the Franseen and Fork-tip needles for EUS-guided fine-needle biopsy sampling of solid pancreatic mass lesions. Gastrointest Endosc 2018; 87: 1432-1438
- 8 Bang JY, Hebert-Magee S, Hasan MK. et al. Endoscopic ultrasonography-guided biopsy using a Franseen needle design: Initial assessment. Dig Endosc 2017; 29: 338-346
- 9 Irisawa A, Hikichi T, Bhutani MS. et al. Basic technique of FNA. Gastrointest Endosc 2009; 69: s125-s129
- 10 Polkowski M, Jenssen C, Kaye P. et al. Technical aspects of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Technical Guideline - March 2017. Endoscopy 2017; 49: 989-1006
- 11 Iwashita T, Nakai Y, Samarasena JB. et al. High single-pass diagnostic yield of a new 25-gauge core biopsy needle for EUS-guided FNA biopsy in solid pancreatic lesions. Gastrointest Endosc 2013; 77: 909-915
- 12 Gerke H, Rizk MK, Vanderheyden AD. et al. Randomized study comparing endoscopic ultrasound-guided Trucut biopsy and fine needle aspiration with high suction. Cytopathology 2010; 21: 44-51
- 13 Kudo T, Kawakami H, Hayashi T. et al. High and low negative pressure suction techniques in EUS-guided fine-needle tissue acquisition by using 25-gauge needles: a multicenter, prospective, randomized, controlled trial. Gastrointest Endosc 2014; 80: 1030-1037.e1031
- 14 Ishiwatari H, Hayashi T, Kawakami H. et al. Randomized trial comparing a side-port needle and standard needle for EUS-guided histology of pancreatic lesions. Gastrointest Endosc 2016; 84: 670-678
- 15 Iglesias-Garcia J, Poley JW, Larghi A. et al. Feasibility and yield of a new EUS histology needle: results from a multicenter, pooled, cohort study. Gastrointest Endosc 2011; 73: 1189-1196
- 16 Park SW, Lee SS, Song TJ. et al. The diagnostic performance of novel torque technique for endoscopic ultrasound-guided tissue acquisition in solid pancreatic lesions: a prospective randomized controlled trial. J Gastroenterol Hepatol 2020; 35: 508-515
- 17 Cotton PB, Eisen GM, Aabakken L. et al. A lexicon for endoscopic adverse events: report of an ASGE workshop. Gastrointest Endosc 2010; 71: 446-454
- 18 Leung KiEL, Lemaistre AI, Fumex F. et al. Macroscopic onsite evaluation using endoscopic ultrasound fine needle biopsy as an alternative to rapid onsite evaluation. Endosc Int Open 2019; 7: E189-E194
- 19 Adler DG, Muthusamy VR, Ehrlich DS. et al. A multicenter evaluation of a new EUS core biopsy needle: Experience in 200 patients. Endosc Ultrasound 2019; 8: 99-104
- 20 Carrara S, Auriemma F, Varadarajulu S. Advances in endoscopic ultrasound-guided tissue acquisition. Techniques in Gastrointestinal Endoscopy 2017; 19: 225-229
- 21 Bang JY, Hebert-Magee S, Navaneethan U. et al. EUS-guided fine needle biopsy of pancreatic masses can yield true histology. Gut 2018; 67: 2081-2084
- 22 Sugiura R, Kuwatani M, Yane K. et al. Prospective, multicenter, observational study of tissue acquisition through EUS-guided fine-needle biopsy using a 25G Franseen needle. Endosc Ultrasound 2019; 8: 321-328
- 23 Facciorusso A, Stasi E, Di Maso M. et al. Endoscopic ultrasound-guided fine needle aspiration of pancreatic lesions with 22 versus 25 Gauge needles: A meta-analysis. United European Gastroenterol J 2017; 5: 846-853
- 24 Mavrogenis G, Weynand B, Sibille A. et al. 25-gauge histology needle versus 22-gauge cytology needle in endoscopic ultrasonography-guided sampling of pancreatic lesions and lymphadenopathy. Endosc Int Open 2015; 3: E63-E68
- 25 Woo YS, Lee KH, Noh DH. et al. 22G versus 25G biopsy needles for EUS-guided tissue sampling of solid pancreatic masses: a randomized controlled study. Scand J Gastroenterol 2017; 52: 1435-1441
- 26 Park SW, Chung MJ, Lee SH. et al. Prospective Study for Comparison of Endoscopic Ultrasound-Guided Tissue Acquisition Using 25- and 22-Gauge Core Biopsy Needles in Solid Pancreatic Masses. PLoS One 2016; 11: e0154401
- 27 Bang JY, Hebert-Magee S, Navaneethan U. et al. Randomized trial comparing the Franseen and Fork-tip needles for EUS-guided fine-needle biopsy sampling of solid pancreatic mass lesions. Gastrointest Endosc 2018; 87: 1432-1438
- 28 Fujita A, Ryozawa S, Mizuide M. et al. Does endoscopic ultrasound-guided fine needle biopsy using a Franseen needle really offer high diagnostic accuracy?. A propensity-matched analysis. Endosc Int Open 2019; 7: E1327-E1332
- 29 Asokkumar R, Yung KaC, Loh T. et al. Comparison of tissue and molecular yield between fine-needle biopsy (FNB) and fine-needle aspiration (FNA): a randomized study. Endosc Int Open 2019; 7: E955-E963
- 30 van Riet PA, Cahen DL, Poley JW. et al. Mapping international practice patterns in EUS-guided tissue sampling: outcome of a global survey. Endosc Int Open 2016; 4: E360-E370
- 31 Arena M, Eusebi LH, Pellicano R. et al. Endoscopic ultrasound core needle for diagnosing of solid pancreatic lesions: is rapid on-site evaluation really necessary?. Minerva Med 2017; 108: 547-553
- 32 Whatcott CJ, Diep CH, Jiang P. et al. Desmoplasia in primary tumors and metastatic lesions of pancreatic cancer. Clin Cancer Res 2015; 21: 3561-3568