RSS-Feed abonnieren
DOI: 10.1055/a-1372-0419
Performance of a new integrated computer-assisted system (CADe/CADx) for detection and characterization of colorectal neoplasia
Abstract
Background Use of artificial intelligence may increase detection of colorectal neoplasia at colonoscopy by improving lesion recognition (CADe) and reduce pathology costs by improving optical diagnosis (CADx).
Methods A multicenter library of ≥ 200 000 images from 1572 polyps was used to train a combined CADe/CADx system. System testing was performed on two independent image sets (CADe: 446 with polyps, 234 without; CADx: 267) from 234 polyps, which were also evaluated by six endoscopists (three experts, three non-experts).
Results CADe showed sensitivity, specificity, and accuracy of 92.9 %, 90.6 %, and 91.7 %, respectively. Experts showed significantly higher accuracy and specificity, and similar sensitivity, while non-experts + CADe showed comparable sensitivity but lower specificity and accuracy than CADe and experts. CADx showed sensitivity, specificity, and accuracy of 85.0 %, 79.4 %, and 83.6 %, respectively. Experts showed comparable performance, whereas non-experts + CADx showed comparable accuracy but lower specificity than CADx and experts.
Conclusions The high accuracy shown by CADe and CADx was similar to that of experts, supporting further evaluation in a clinical setting. When using CAD, non-experts achieved a similar performance to experts, with suboptimal specificity.
Publikationsverlauf
Eingereicht: 16. Juli 2020
Angenommen: 25. Januar 2021
Accepted Manuscript online:
25. Januar 2021
Artikel online veröffentlicht:
20. April 2021
© 2021. Thieme. All rights reserved.
Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany
-
References
- 1 Pilonis ND, Bugajski M, Wieszczy P. et al. Long-term colorectal cancer incidence and mortality after a single negative screening colonoscopy. Ann Intern Med 2020; 173: 81-91
- 2 Wieszczy P, Kaminski MF, Franczyk R. et al. Colorectal cancer incidence and mortality after removal of adenomas during screening colonoscopies. Gastroenterology 2020; 158: 875-883
- 3 Anderson R, Burr NE, Valori R. Causes of post-colonoscopy colorectal cancers based on World Endoscopy Organization system of analysis. Gastroenterology 2020; 158: 1287-1299
- 4 Fuccio L, Rex D, Ponchon T. et al. New and recurrent colorectal cancers after resection: a systematic review and meta-analysis of endoscopic surveillance studies. Gastroenterology 2019; 156: 1309-1323
- 5 Zhao S, Wang S, Pan P. et al. Magnitude, risk factors, and factors associated with adenoma miss rate of tandem colonoscopy: a systematic review and meta-analysis. Gastroenterology 2019; 156: 1661-1674
- 6 Greuter MJE, de Klerk CM, Meijer GA. et al. Screening for colorectal cancer with fecal immunochemical testing with and without postpolypectomy surveillance colonoscopy: a cost-effectiveness analysis. Ann Intern Med 2017; 167: 544-554
- 7 Gupta N, Bansal A, Rao D. et al. Prevalence of advanced histological features in diminutive and small colon polyps. Gastrointest Endosc 2012; 75: 1022-1030
- 8 Hassan C, Pickhardt PJ, Rex DK. A resect and discard strategy would improve cost-effectiveness of colorectal cancer screening. Clin Gastroenterol Hepatol 2010; 8: 865-869
- 9 Rex DK, Kahi C, O’Brien M. et al. The American Society for Gastrointestinal Endoscopy PIVI (Preservation and Incorporation of Valuable Endoscopic Innovations) on real-time endoscopic assessment of the histology of diminutive colorectal polyps. Gastrointest Endosc 2011; 73: 419-422
- 10 Bisschops R, East JE, Hassan C. et al. Advanced imaging for detection and differentiation of colorectal neoplasia: European Society of Gastrointestinal Endoscopy (ESGE) Guideline – Update 2019. Endoscopy 2019; 51: 1155-1179