Rofo 2021; 193(11): 1254-1257 DOI: 10.1055/a-1467-6548
Die Rolle von mittels „Virtual Non Calcium“ errechneten Dual-Energy-CTs zur Beurteilung des Knochenmarks in der klinischen Routine onkologischer Patienten
The role of calculated dual energy CTs using “Virtual Non Calcium” for assessing the bone marrow in the clinical routine of oncological patients
1
Abteilung für Diagnostische und Interventionelle Radiologie, Universitätsklinikum Tübingen, Tübingen, Germany
,
2
Radiologie, Universitätsklinikum Tübingen, Tübingen, Germany
,
Karolin Baumgartner
1
Abteilung für Diagnostische und Interventionelle Radiologie, Universitätsklinikum Tübingen, Tübingen, Germany
,
Marius Horger
1
Abteilung für Diagnostische und Interventionelle Radiologie, Universitätsklinikum Tübingen, Tübingen, Germany
› Institutsangaben
Literatur
1
Abdullayev N,
Große Hokamp N,
Lennartz S.
et al
Improvements of diagnostic accuracy and visualization of vertebral metastasis using multi-level virtual non-calcium reconstructions from dual-layer spectral detector computed tomography. European radiology 2019; 29: 5941-5949
2
de Cecco CN,
Darnell A,
Rengo M.
et al
Dual-energy CT: oncologic applications. Am J Roentgenol. American journal of roentgenology 2012; 199 (Suppl. 05) S98-S105
3
Johnson TRC.
Dual-energy CT: general principles. Am J Roentgenol. American journal of roentgenology 2012; 199 (Suppl. 05) S3-S8
4
Kosmala A,
Weng AM,
Heidemeier A.
et al
Multiple Myeloma and Dual-Energy CT: Diagnostic Accuracy of Virtual Noncalcium Technique for Detection of Bone Marrow Infiltration of the Spine and Pelvis. Radiology 2018; 286: 205-213
5
Kosmala A,
Weng AM,
Krauss B.
et al
Dual-energy CT of the bone marrow in multiple myeloma: diagnostic accuracy for quantitative differentiation of infiltration patterns. European radiology 2018; 28: 5083-5090
6
Liu X,
Yu L,
Primak A.
et al
Quantitative imaging of element composition and mass fraction using dual-energy CT: three-material decomposition. Medical physics 2009; 36: 1602-1609
7
McCollough CH,
Leng S,
Yu L.
et al
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications. Radiology 2015; 276: 637-653
8
Nicolaou S,
Liang T,
Murphy DT.
et al
Dual-energy CT: a promising new technique for assessment of the musculoskeletal system. Am J Roentgenol. American journal of roentgenology 2012; 199 (Suppl. 05) S78-S86
9
Ricci C,
Cova M,
Kang YS.
et al
Normal age-related patterns of cellular and fatty bone marrow distribution in the axial skeleton: MR imaging study. Radiology 1990; 177: 83-88
10
Thomas C,
Schabel C,
Krauss B.
et al
Dual-energy CT: virtual calcium subtraction for assessment of bone marrow involvement of the spine in multiple myeloma. Am J Roentgenol. American journal of roentgenology 2015; 204: W324-W331