Subscribe to RSS
DOI: 10.1055/a-1682-7095
Novel 15-mm-long lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections located ≥10 mm from the luminal wall
Abstract
Background Endoscopic ultrasound (EUS)-guided drainage of pancreatic fluid collections (PFCs) by cautery-enhanced lumen-apposing metal stents (LAMS) has largely been limited to collections located < 10 mm from the luminal wall. We present outcomes of the use of a novel 15-mm-long cautery-enhanced LAMS for drainage of PFCs located ≥ 10 mm away.
Methods This international, multicenter study analyzed all adults with PFCs located ≥ 10 mm from the luminal wall who were treated by EUS-guided drainage using the 15-mm-long cautery-enhanced LAMS. The primary outcome was technical success. Secondary outcomes included clinical success (decrease in PFC size by ≥ 50 % at 30 days and resolution of clinical symptoms without surgical intervention), complications, and recurrence.
Results 35 patients (median age 57 years; interquartile range [IQR] 47–64 years; 49 % male) underwent novel LAMS placement for drainage of PFCs (26 walled-off necrosis, 9 pseudocysts), measuring 85 mm (IQR 64–117) maximal diameter and located 11.8 mm (IQR 10–12.3; range 10–14) from the gastric/duodenal wall. Technical and clinical success were high (both 97 %), with recurrence in one patient (3 %) at a median follow-up of 123 days (58–236). Three complications occurred (9 %; one mild, two moderate).
Conclusions The 15-mm-long cautery-enhanced LAMS was feasible and safe for drainage of PFCs located 10–14 mm from the luminal wall.
Publication History
Received: 09 June 2021
Accepted after revision: 22 September 2021
Article published online:
14 December 2021
© 2021. Thieme. All rights reserved.
Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany
-
References
- 1 Banks PA, Bollen TL, Dervenis C. et al. Classification of acute pancreatitis – 2012: revision of the Atlanta classification and definitions by international consensus. Gut 2013; 62: 102-111
- 2 Arvanitakis M, Dumonceau JM, Albert J. et al. Endoscopic management of acute necrotizing pancreatitis: European Society of Gastrointestinal Endoscopy (ESGE) evidence-based multidisciplinary guidelines. Endoscopy 2018; 50: 524-546
- 3 Cotton PB, Eisen GM, Aabakken L. et al. A lexicon for endoscopic adverse events: report of an ASGE workshop. Gastrointest Endosc 2010; 71: 446-454
- 4 Baron TH, DiMaio CJ, Wang AY. et al. American Gastroenterological Association Clinical Practice Update: Management of pancreatic necrosis. Gastroenterology 2020; 158: 67-75
- 5 Muthusamy VR, Chandrasekhara V. ASGE Standards of Practice Committee. et al. The role of endoscopy in the diagnosis and treatment of inflammatory pancreatic fluid collections. Gastrointest Endosc 2016; 83: 481-488
- 6 Chandran S, Efthymiou M, Kaffes A. et al. Management of pancreatic collections with a novel endoscopically placed fully covered self-expandable metal stent: a national experience (with videos). Gastrointest Endosc 2015; 81: 127-135
- 7 Bekkali NLH, Nayar MK, Leeds JS. et al. A comparison of outcomes between a lumen-apposing metal stent with electrocautery-enhanced delivery system and a bi-flanged metal stent for drainage of walled-off pancreatic necrosis. Endosc Int Open 2017; 5: E1189-E1196
- 8 Lang GD, Fritz C, Bhat T. et al. EUS-guided drainage of peripancreatic fluid collections with lumen-apposing metal stents and plastic double-pigtail stents: comparison of efficacy and adverse event rates. Gastrointest Endosc 2018; 87: 150-157
- 9 Puga M, Consiglieri CF, Busquets J. et al. Safety of lumen-apposing stent with or without coaxial plastic stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: a retrospective study. Endoscopy 2018; 50: 1022-1026
- 10 Bang JY, Hasan M, Navaneethan U. et al. Lumen-apposing metal stents (LAMS) for pancreatic fluid collection (PFC) drainage: may not be business as usual. Gut 2017; 66: 2054-2056
- 11 Yang J, Chen YI, Friedland S. et al. Lumen-apposing stents versus plastic stents in the management of pancreatic pseudocysts: a large, comparative, international, multicenter study. Endoscopy 2019; 51: 1035-1043
- 12 Garcia-Alonso FJ, Sanchez-Ocana R, Peñas-Herrero I. et al. Cumulative risks of stent migration and gastrointestinal bleeding in patients with lumen-apposing metal stents. Endoscopy 2018; 50: 386-395
- 13 Bang JY, Navaneethan U, Hasan MK. et al. Non-superiority of lumen-apposing metal stents over plastic stents for drainage of walled-off necrosis in a randomised trial. Gut 2019; 68: 1200-1209
- 14 Lang GD, Fritz C, Bhat T. et al. EUS-guided drainage of peripancreatic fluid collections with lumen-apposing metal stents and plastic double-pigtail stents: comparison of efficacy and adverse event rates. Gastrointest Endosc 2018; 87: 150-157
- 15 Teoh AYB, Bapaye A, Lakhtakia S. et al. Prospective multicenter international study on the outcomes of a newly developed self-approximating lumen-apposing metallic stent for drainage of pancreatic fluid collections and endoscopic necrosectomy. Dig Endosc 2020; 32: 391-398
- 16 Chen YI, Khashab MA, Adam V. et al. Plastic stents are more cost-effective than lumen-apposing metal stents in management of pancreatic pseudocysts. Endosc Int Open 2018; 6: E780-E788
- 17 Ross AS, Irani S, Gan SI. et al. Dual-modality drainage of infected and symptomatic walled-off pancreatic necrosis: long-term clinical outcomes. Gastrointest Endosc 2014; 79: 929-935
- 18 Varadarajulu S, Phadnis MA, Christein JD. et al. Multiple transluminal gateway technique for EUS-guided drainage of symptomatic walled-off pancreatic necrosis. Gastrointest Endosc 2011; 74: 74-80