Mucosal defect closure using a calibrated, small-caliber-tip, transparent hood after colorectal endoscopic submucosal dissection
Complete closure of a mucosal defect using a clip with a transparent cylindrical hood reduces the occurrence of adverse incidents after colorectal endoscopic submucosal dissection (ESD) [1]. Thus, we developed the “reopenable clip over the line method” (ROLM), a technique that uses a line and a reopenable clip (SureClip, 16 mm; MC Medical, Tokyo, Japan) to close a mucosal defect after ESD [2]. With the ROLM, the mucosal defect can be closed completely without clipping its edges on both sides [3]. However, when a cylindrical hood is used, there is a risk that the clip could enter the hood and impede the endoscopic view ([Fig. 1 a, b]). For this reason, we performed the ROLM using a calibrated, small-caliber-tip, transparent hood (CAST hood; TOP, Tokyo, Japan), to prevent the clips deployed for the mucosal defect closure from interfering with the endoscopic view ([Fig. 1 c, d]).
The CAST hood is a tapered hood with a 4-mm tip [4] that allows the clips that are fixed to close the mucosal defect to be deflected out of the hood by the edges of the hood. It can also be used under water to maintain the endoscopic field of view intraoperatively [5].
In our case, the patient had early rectal cancer that was completely resected by ESD. The resected mucosal defect was approximately 5 cm in size, straddled the folds, and was completely closed using the ROLM with a CAST hood ([Fig. 2]; [Video 1]). The reopenable clips did not interfere with the endoscopic view during the ROLM. A cylindrical hood with a large diameter is not always necessary because the ROLM allows the mucosal defect to be closed by grasping only the defect and the nearby muscularis propria, without grasping the edges on both sides of the mucosal defect.
Video 1 Closure of a postendoscopic submucosal dissection mucosal defect using the reopenable clip over the line method and a calibrated, small-caliber-tip, transparent hood.
Quality:
Endoscopy_UCTN_Code_TTT_1AO_2AI
Endoscopy E-Videos is an open access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online. Processing charges apply (currently EUR 375), discounts and wavers acc. to HINARI are available.
This section has its own submissionwebsite athttps://mc.manuscriptcentral.com/e-videos
Publication History
Article published online:
18 February 2022
© 2022. Thieme. All rights reserved.
Georg Thieme Verlag KG
Rüdigerstraße 14, 70469 Stuttgart, Germany
-
References
- 1 Albéniz E, Álvarez MA, Espinós JC. et al. Clip closure after resection of large colorectal lesions with substantial risk of bleeding. Gastroenterology 2019; 157: 1213-1221
- 2 Nomura T, Sugimoto S, Kawabata M. et al. Large colorectal mucosal defect closure post-endoscopic submucosal dissection using the reopenable clip over line method and modified locking-clip technique. Endoscopy 2021; DOI: 10.1055/a-1381-6435.
- 3 Nomura T, Sugimoto S, Temma T. et al. Clip-line closure with the reopenable clip over line method for a large mucosal defect after gastric endoscopic submucosal dissection. Endoscopy 2022; 54: E1-E2 DOI: 10.1055/a-1346-8991.
- 4 Hayashi Y, Yamamoto H, Yano T. et al. A calibrated, small-caliber tip, transparent hood to aid endoscopic balloon dilation of intestinal strictures in Crohn’s disease: successful use of prototype. Endoscopy 2013; 45: E373-E374
- 5 Nomura T, Sugimoto S, Oyamada J. et al. GI endoscopic submucosal dissection using a calibrated, small-caliber-tip, transparent hood for lesions with fibrosis. VideoGIE 2021; 6: 301-304 DOI: 10.1016/j.vgie.2021.03.001.