RSS-Feed abonnieren
DOI: 10.1055/a-2113-8528
Feasibility of Cerebellar Measurements with Phased Array Sonography through the Anterior Fontanelle in Comparison to MRI
Funding None.Abstract
Objective Cerebral sonography (CS) through the anterior fontanelle is a neonatal brain imaging method that has become an integral part of modern neonatal bedside care for both screening and diagnostic purposes. Premature infants with cognitive delay have a reduction in cerebellar size at term corrected age on magnetic resonance imaging (MRI). We aimed to determine the level of agreement between postnatal MRI and CS for cerebellar biometry and to determine the level of agreement within one and between different examiners.
Study Design Cerebellar sonography and MRI measurements of the cerebellum from 30 term infants was assessed by Bland–Altman plots. Measurements between both modalities were compared using Wilcoxon's signed rank test. A p-value < 0.01 was considered statistically significant. Intraclass correlation coefficients (ICC) for intra- and interrater reliabilities of CS measurements were calculated.
Results There was no statistically significant difference between CS and MRI for linear measurements, but the measurements of perimeter and surface area differed significantly between the two techniques. There was a systematic bias between both modalities for most measurements except for anterior–posterior (AP) width and vermis height (VH). For measurements that were not statistically different from MRI, we found excellent intrarater ICC for the AP width, VH, and cerebellar width. The interrater ICC was excellent for the AP width and VH, but poor for the transverse cerebellar width.
Conclusion With a strict imaging protocol, cerebellar measurements of the AP width and the VH can be used as an alternative to MRI for diagnostic-screening purposes in a neonatal department where multiple clinicians perform bedside CS.
Key Points
-
Abnormal cerebellar growth and injuries affect neurodevelopmental outcome.
-
Cerebral sonography through the anterior fontanelle is used for bedside imaging.
-
Postnatal sonographic cerebellar measurements are not validated against MRI.
-
Measuring vermis height and anterior–posterior width are reliable.
-
Measuring transverse cerebellar width through anterior fontanelle is unreliable.
Ethics Approval
Ethics approval not required as per HRA Guidance. Approved by local Hospital Trust Governance Committee.
Note
This manuscript has not been published or is being submitted elsewhere.
Publikationsverlauf
Eingereicht: 04. Februar 2023
Angenommen: 16. Juni 2023
Accepted Manuscript online:
20. Juni 2023
Artikel online veröffentlicht:
21. Juli 2023
© 2023. Thieme. All rights reserved.
Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA
-
References
- 1 Fumagalli M, Parodi A, Ramenghi L, Limperopoulos C, Steggerda S. eurUS.brain group. Ultrasound of acquired posterior fossa abnormalities in the newborn. Pediatr Res 2020; 87 (suppl 1): 25-36
- 2 Jaeger E, Silveira RC, Procianoy RS. Cerebellar growth in very low birth weight infants. J Perinatol 2011; 31 (12) 757-759
- 3 Graça AM, Geraldo AF, Cardoso K, Cowan FM. Preterm cerebellum at term age: ultrasound measurements are not different from infants born at term. Pediatr Res 2013; 74 (06) 698-704
- 4 Sancak S, Gursoy T, Imamoglu EY, Karatekin G, Ovali F. Effect of prematurity on cerebellar growth. J Child Neurol 2016; 31 (02) 138-144
- 5 Sancak S, Gursoy T, Karatekin G, Ovali F. Effect of intraventricular hemorrhage on cerebellar growth in preterm neonates. Cerebellum 2017; 16 (01) 89-94
- 6 Leijser LM, Srinivasan L, Rutherford MA, Counsell SJ, Allsop JM, Cowan FM. Structural linear measurements in the newborn brain: accuracy of cranial ultrasound compared to MRI. Pediatr Radiol 2007; 37 (07) 640-648
- 7 Benavente-Fernández I, Rodríguez-Zafra E, León-Martínez J. et al. Normal cerebellar growth by using three-dimensional US in the preterm infant from birth to term-corrected age. Radiology 2018; 288 (01) 254-261
- 8 Spinelli M, Sica C, Meglio LD, Bolla D, Raio L, Surbek D. Fetal cerebellar vermis circumference measured by 2-dimensional ultrasound scan: reference range, feasibility and reproducibility. Ultrasound Int Open 2016; 2 (04) E124-E128
- 9 da Graça ALFM, Cardoso KRV, da Costa JMFP, Cowan FM. Assessment of gestational age using cerebellar measurements at cranial ultrasound: what is the best approach?. Early Hum Dev 2013; 89 (01) 1-5
- 10 Swaminathan M, Davies M, Davis P, Betheras F. Transverse cerebellar diameter on cranial ultrasound scan in preterm neonates in an Australian population. J Paediatr Child Health 1999; 35 (04) 346-349
- 11 Davies MW, Swaminathan M, Betheras FR. Measurement of the transverse cerebellar diameter in preterm neonates and its use in assessment of gestational age. Australas Radiol 2001; 45 (03) 309-312
- 12 Armstrong RK, Fox LM, Cheong JLY, Davis PG, Rogerson SK. Postnatal ultrasound reliability in cerebellar vermis assessment. Arch Dis Child Fetal Neonatal Ed 2012; 97 (04) F307-F309
- 13 Correa F, Cunha M, Barroso R, Carreiro H. Risk of impaired cerebellar growth in preterm infants: a prospective mastoid fontanelle ultrasound study. Journal of Pediatric and Neonatal Individualized Medicine. 2014;3(02):
- 14 Yalin Imamoglu E, Gursoy T, Sancak S, Ovali F. Does being born small-for-gestational-age affect cerebellar size in neonates?. J Matern Fetal Neonatal Med 2016; 29 (06) 892-896
- 15 Bravo MC, Valverde E. Reliability in cerebellar size assessment by 2D cranial ultrasonography in neonates. Eur J Paediatr Neurol 2017; 21 (04) 610-613