RSS-Feed abonnieren
DOI: 10.1055/a-2451-6924
A Retrospective Review of Revision and Re-revision Patella Osteosynthesis Performed for Failure of Fixation of Initial Comminuted Fracture Patterns: Very High Complication Rates

Abstract
Literature on revision osteosynthesis for failed patella fracture fixation is extremely limited. This study reviews the treatment options and outcomes for revision and re-revision osteosynthesis at a Level 1 trauma center. All patella revision osteosynthesis cases between January 2021 and March 2024 were identified using Current Procedural Terminology codes at a single tertiary care academic center. Medical records, operative reports, and radiographs were reviewed to collect details regarding patient demographics, initial injury and fracture management, indications for revision surgery, revision construct, postoperative weight bearing and range-of-motion restrictions, and outcomes. The primary outcome was major failure defined as loss of fixation or further surgery for nonunion or infection. Ten patients underwent revision osteosynthesis for failed fixation. All fractures were initially comminuted fracture patterns (AO/OTA 34-C3), with nine (90%) initially treated with a 2.7-mm patella-specific variable angle locking plate (Synthes, Paoli, PA). Half (n = 5) of the patients were revised with the same patella-specific plate and half with an all suture transosseous fibertape tension band (Arthrex, Naples, FL). Additional fixation in the form of bony augmentation was performed in 20% (n = 2) of cases and soft tissue augmentation in 70% (n = 7). There was a 70% (n = 7) major failure rate, mostly due to loss of inferior pole fixation. There were four re-revision procedures performed with surgical fixation. Two of these subsequently developed infection, one united and the other had no radiographic signs of union and was lost to follow-up, but was without complication. Regardless of the chosen fixation construct, revision osteosynthesis for failed fixation of initial comminuted fracture patterns has an extremely high rate of failure. Complications increase with further revision surgery. Level of evidence: therapeutic level 3.
Publikationsverlauf
Eingereicht: 22. Juni 2024
Angenommen: 23. Oktober 2024
Accepted Manuscript online:
24. Oktober 2024
Artikel online veröffentlicht:
19. November 2024
© 2024. Thieme. All rights reserved.
Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA
-
References
- 1 Hargett DI, Sanderson BR, Little MTM. Patella fractures: approach to treatment. J Am Acad Orthop Surg 2021; 29 (06) 244-253
- 2 Matthews B, Hazratwala K, Barroso-Rosa S. Comminuted patella fracture in elderly patients: a systematic review and case report. Geriatr Orthop Surg Rehabil 2017; 8 (03) 135-144
- 3 Alley MC, Kain M, Mitchell S, Walker BJ, Jones CB, Tornetta III P. Anterior hook plating of patella fractures: a biomechanical analysis and clinical series. J Orthop Trauma 2023; 37 (06) e258-e263
- 4 Verbeek DO, Hickerson LE, Warner SJ, Helfet DL, Lorich DG. Low profile mesh plating for patella fractures: video of a novel surgical technique. J Orthop Trauma 2016; 30 (Suppl. 02) S32-S33
- 5 Volgas D, Dreger TK. The use of mesh plates for difficult fractures of the patella. J Knee Surg 2017; 30 (03) 200-203
- 6 Singer MS, Halawa AM, Adawy A. Outcome of low profile mesh plate in management of comminuted displaced fracture patella. Injury 2017; 48 (06) 1229-1235
- 7 Siljander MP, Vara AD, Koueiter DM, Wiater BP, Wiater PJ. Novel anterior plating technique for patella fracture fixation. Orthopedics 2017; 40 (04) e739-e743
- 8 Moore TB, Sampathi BR, Zamorano DP, Tynan MC, Scolaro JA. Fixed angle plate fixation of comminuted patellar fractures. Injury 2018; 49 (06) 1203-1207
- 9 Tengler MB, Lill H, Wente M, Ellwein A. Anterior locking plate osteosynthesis of patellar factures - analysis of complications and functional outcome [in German]. Z Orthop Unfall 2022; 160 (05) 549-558
- 10 Jang JH, Rhee SJ, Kim JW. Hook plating in patella fractures. Injury 2019; 50 (11) 2084-2088
- 11 Brusalis CM, Gruskay JA, Bornes TD, Langhans MT, Ricci WM. Open reduction and internal fixation of patella fracture with contoured dorsal plating. J Orthop Trauma 2021; 35 (Suppl. 02) S34-S35
- 12 Yoo SJ, Ok S, Lee J, Choi S. Can multiple miniplates improve the treatment of comminuted patellar fracture?. BMC Musculoskelet Disord 2023; 24 (01) 936
- 13 Cancio-Bello AM, Owen AR, Kuttner NP. et al. Patella fracture fixation with novel wagon wheel construct versus tension-band construct: a technical trick. J Orthop Trauma 2023; 37 (11) e452-e458
- 14 Cho JW, Kent WT, Cho WT. et al. Miniplate augmented tension-band wiring for comminuted patella fractures. J Orthop Trauma 2019; 33 (04) e143-e150
- 15 Kim KS, Suh DW, Park SE, Ji JH, Han YH, Kim JH. Suture anchor fixation of comminuted inferior pole patella fracture-novel technique: suture bridge anchor fixation technique. Arch Orthop Trauma Surg 2021; 141 (11) 1889-1897
- 16 Gu H, Zhu S, Li T, Wu X. Combination of cable cerclage and hook plate for the fixation of comminuted fractures of inferior patellar pole: a review of 16 consecutive patients followed up for a minimum of 1 year. Orthop Surg 2022; 14 (11) 3111-3118
- 17 Suh KT, Suh JD, Cho HJ. Open reduction and internal fixation of comminuted patellar fractures with headless compression screws and wiring technique. J Orthop Sci 2018; 23 (01) 97-104
- 18 Cho JW, Kim J, Cho WT, Gujjar PH, Oh CW, Oh JK. Comminuted inferior pole fracture of patella can be successfully treated with rim-plate-augmented separate vertical wiring. Arch Orthop Trauma Surg 2018; 138 (02) 195-202
- 19 D'Ambrosio M, Tang A, Menken L, Hagag AT, Liporace FA, Yoon RS. Adjunct neutralization plating in patella fracture fixation: a technical trick. OTA Int 2022; 5 (04) e217
- 20 Yao C, Sun J, Wu J. et al. Clinical outcomes of Ti-Ni shape-memory patella concentrator combined with cannulated compression screws in the treatment of C2 and C3 patella fracture: a retrospective study of 54 cases. BMC Musculoskelet Disord 2020; 21 (01) 506
- 21 Moser-De Mesa SS, Italia K, Tanchuling Jr A. Modified cerclage and suture mesh fixation for comminuted patellar fracture - “Cobweb Technique”: a case report. Trauma Case Rep 2023; 48: 100963
- 22 Kfuri M, Escalante I, Schopper C. et al. Comminuted patellar fractures: the role of biplanar fixed angle plate constructs. J Orthop Translat 2020; 27 (27) 17-24
- 23 Stoffel K, Zderic I, Pastor T. et al. Anterior variable-angle locked plating versus tension band wiring of simple and complex patella fractures - a biomechanical investigation. BMC Musculoskelet Disord 2023; 24 (01) 279
- 24 Warner S, Sommer C, Zderic I. et al. Lateral rim variable angle locked plating versus tension band wiring of simple and complex patella fractures: a biomechanical study. Arch Orthop Trauma Surg 2024; 144 (05) 2131-2140
- 25 Marsh JL, Slongo TF, Agel J. et al. Fracture and dislocation classification compendium - 2007: Orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma 2007; 21 (10, Suppl): S1-S133
- 26 Monaco E, Caperna L, Cardarelli S. et al. Transverse patellar fracture fixation with tape cerclage in a patient with a history of complicated contralateral patellar fracture fixation with metallic hardware. Int J Burns Trauma 2020; 10 (06) 307-313
- 27 Bansal H, Behera A, Sharma V, Farooque K. Patella locking star-plate as salvage to the failed tension band wiring for a patella fracture: a case report. Case Rep Orthop Res 2022; 5: 13-17
- 28 Xue Z, Qin H, Ding H, Xu H, An Z. Two-Tenson-Band technique in revision surgery for fixation failure of patellar fractures. Med Sci Monit 2016; 22: 2736-2741
- 29 Müller EC, Frosch KH. Functional outcomes of revision osteosynthesis after failure of surgical treatment of patellar fractures. J Knee Surg 2021; 34 (01) 80-86
- 30 Lowe DT, Jazrawi LM, Egol KA. Revision patella tendon repair with hamstring tendon autograft augmentation following failed inferior pole patella fracture open reduction and internal fixation. J Orthop Trauma 2022; 36 (Suppl. 03) S21-S22