J Wrist Surg
DOI: 10.1055/a-2506-6910
Scientific Article

Kinematics of the Distal Radioulnar Joint: A Dynamic CT Analysis

1   Department of Orthopaedic Surgery, Tauranga Hospital, Tauranga South, Tauranga, New Zealand
,
2   Upper Limb and Research, Department of Orthopaedic Surgery, Flinders University and Flinders Medical Centre, Adelaide, South Australia, Australia
,
3   Department of Orthopaedic Surgery, Tauranga Hospital, Tauranga South, Tauranga, New Zealand
› Author Affiliations
Funding None.

Abstract

Background The kinematics of the distal radioulnar joint (DRUJ) are complex and not fully understood. Much current knowledge is based on cadaveric and static imaging studies. Management of DRUJ pathology will remain a challenge until the anatomy and kinematics at the normal DRUJ are defined. The aim of this study was to report kinematic findings at the DRUJ and their relationships in normal wrists using static and dynamic computed tomography (CT).

Materials and Methods This was a retrospective cohort study of patients who underwent dynamic CT scanning of one or both wrists at Tauranga Hospital between March 2018 and July 2022, utilizing a previously described protocol. Sigmoid notch and ulnar head dimensions in the axial and coronal planes were measured on static imaging, with sigmoid notch morphologies described utilizing the Tolat classifications. The degree of translation of the ulnar head with the wrist in full pronation, neutral rotation, and full supination were measured relative to a perpendicular line drawn across the midpoint of the sigmoid notch. The ulnar variance and sigmoid notch gap on coronal views were measured with the wrist in radial and ulnar deviation and with a relaxed and clenched fist.

Results A total of 38 wrists were studied in 24 patients, consisting of 15 females and 9 males with a mean age of 38.0 years (range 15–61). There was no statistically significant difference between ulnar variance or translation of the ulna relative to the midpoint of the sigmoid notch in each position when compared for morphology types in coronal or axial planes. The mean radius of curvature of the ulnar head was 8.3 degrees, with the mean radius of the sigmoid notch measuring 17.1 degrees (p < 0.001), at a mean ratio of 0.51. The ulnar head was most dorsal to the midpoint of the sigmoid notch in full pronation (mean −2.8 mm dorsal), and translated volarly as the wrist moved toward neutral (mean −1.1 mm dorsal) and to full supination (mean −0.6 mm dorsal) (p < 0.001), but remained dorsal to the sigmoid notch midpoint in each position. The mean sigmoid notch gap was 1.3 mm relaxed, which increased to 2.0 mm in a clenched fist (p = 0.001). Mean ulnar variance measured −1.0 mm relaxed, and −0.5 mm in a clenched fist (p = 0.014). The mean sigmoid notch gap on radial deviation was 2.0 mm, and 1.4 mm on ulnar deviation (p = 0.012).

Conclusion The ulnar head remains dorsal relative to the midpoint of the sigmoid notch throughout the range of forearm rotation but becomes relatively more volar as the wrist rotates from full pronation to a position of full supination. The morphology of the notch was not associated with any parameter measured in our study. We have shown that ulnar variance is dynamic in response to deviation and loading. We have presented new data that loading and ulnar deviation increase the gap at the distal sigmoid notch between the radius and ulna. Our findings have implications in the surgical management of pathologies at the joint, particularly in reconstructive procedures for DRUJ instability. Further study is indicated to investigate the relationship between morphology and kinematics at the DRUJ.



Publication History

Received: 18 October 2024

Accepted: 19 December 2024

Article published online:
30 January 2025

© 2025. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Haugstvedt JR, Langer MF, Berger RA. Distal radioulnar joint: functional anatomy, including pathomechanics. J Hand Surg Eur Vol 2017; 42 (04) 338-345
  • 2 Tolat AR, Stanley JK, Trail IA. A cadaveric study of the anatomy and stability of the distal radioulnar joint in the coronal and transverse planes. J Hand Surg [Br] 1996; 21 (05) 587-594
  • 3 Qazi S, Graham D, Regal S, Tang P, Hammarstedt JE. Distal radioulnar joint instability and associated injuries: a literature review. J Hand Microsurg 2021; 13 (03) 123-131
  • 4 Nakamura R, Horii E, Imaeda T, Tsunoda K, Nakao E. Distal radioulnar joint subluxation and dislocation diagnosed by standard roentgenography. Skeletal Radiol 1995; 24 (02) 91-94
  • 5 Nakamura R, Horii E, Imaeda T, Nakao E. Criteria for diagnosing distal radioulnar joint subluxation by computed tomography. Skeletal Radiol 1996; 25 (07) 649-653
  • 6 Steinbach LS, Smith DK. MRI of the wrist. Clin Imaging 2000; 24 (05) 298-322
  • 7 Jens S, Luijkx T, Smithuis FF, Maas M. Diagnostic modalities for distal radioulnar joint. J Hand Surg Eur Vol 2017; 42 (04) 395-404
  • 8 Oldfield CE, Boland MR, Greybe D, Hing W. Ultrasound imaging of the distal radioulnar joint: a new method to assess ulnar radial translation in forearm rotation. J Hand Surg Eur Vol 2017; 42 (04) 389-394
  • 9 MacLean SBM, Bain G, Carr R. 4D-CT and dynamic MRI assessment of elbow disorders. In: Bain G, Eygendaal D, van Riet R. eds. Surgical Techniques for Trauma and Sports Related Injuries of the Elbow. Springer, Berlin: Heidelberg; 2020: 67-72
  • 10 Bain GI, Krishna SV, MacLean S, Carr R, Slavotinek J. “Locked” scapholunate instability diagnosed with 4D computed tomography scan. [published correction appears in J Wrist Surg. 2019 Aug;8(4):e1. doi: 10.1055/s-0039-1679937] J Wrist Surg 2019; 8 (04) 321-326
  • 11 Alta TD, Bell SN, Troupis JM, Coghlan JA, Miller D. The new 4-dimensional computed tomographic scanner allows dynamic visualization and measurement of normal acromioclavicular joint motion in an unloaded and loaded condition. J Comput Assist Tomogr 2012; 36 (06) 749-754
  • 12 Braig ZV, Dittman LE, Amrami KK, Kakar S. Dynamic computed tomography of the distal radioulnar joint versus magnetic resonance imaging in detecting foveal tears of the triangular fibrocartilage complex. Hand (N Y) 2024; x: 15 589447241232012
  • 13 Carr R, MacLean S, Slavotinek J, Bain GI. Four-dimensional computed tomography scanning for dynamic wrist disorders: prospective analysis and recommendations for clinical utility. J Wrist Surg 2019; 8 (02) 161-167
  • 14 Jung JM, Baek GH, Kim JH, Lee YH, Chung MS. Changes in ulnar variance in relation to forearm rotation and grip. J Bone Joint Surg Br 2001; 83 (07) 1029-1033
  • 15 Yeh GL, Beredjiklian PK, Katz MA, Steinberg DR, Bozentka DJ. Effects of forearm rotation on the clinical evaluation of ulnar variance. J Hand Surg Am 2001; 26 (06) 1042-1046
  • 16 D'Sa H, Willing R, Murray T. et al. Reliability of the sigmoid notch classification of the distal radioulnar joint. J Wrist Surg 2022; 12 (04) 359-363
  • 17 Roner S, Fürnstahl P, Scheibler AG, Sutter R, Nagy L, Carrillo F. Three-dimensional automated assessment of the distal radioulnar joint morphology according to sigmoid notch surface orientation. J Hand Surg Am 2020; 45 (11) 1083.e1-1083.e11