Rofo 2009; 181(11): 1050-1055
DOI: 10.1055/s-0028-1109503
Herz

© Georg Thieme Verlag KG Stuttgart · New York

Flow-Targeted Inversion-Prepared b-TFE Coronary MR Angiography: Initial Results in Patients

b-TFE MR-Koronarangiografie mit einem Inversionspuls zur Darstellung des koronaren Blutflusses: erste Ergebnisse bei PatientenM. Katoh1 , 5 , E. Spüntrup2 , H. Kuehl3 , M. Stuber4 , R. W. Günther5 , R. M. Botnar6
  • 1Department of Diagnostic and Interventional Radiology, University Hospital Saarland Homburg
  • 2Department of Radiology, University Hospital Cologne
  • 3Klinik für Kardiologie, Pneumologie und Angiologie, Universitätsklinikum RWTH Aachen
  • 4Department of Radiology, Division of MRI Research, Johns Hopkins University Medical School
  • 5Klinik für Radiologische Diagnostik, Universitätsklinikum RWTH Aachen
  • 6Cardiovascular Imaging, Imaging Sciences Division, King’s College London
Further Information

Publication History

received: 4.2.2009

accepted: 4.5.2009

Publication Date:
14 October 2009 (online)

Zusammenfassung

Ziel: Modifikation einer mit einem selektiven Inversionspuls ausgestatteten MR-Koronarangiografie-Sequenz zur Darstellung des koronaren Blutflusses im rechten und linken Koronarsystem und Anwendung der gleichen in Probanden und Patienten. Material und Methoden: Bei 14 gesunden Probanden und 19 Patienten wurden die Koronararterien mit einem 1,5 Tesla-MR-Tomografen und einer 3-D-balanced-Turbo-Fiel-Echo-Sequenz (b-TFE-Sequenz) mit radialer k-Raum-Abtastung untersucht. Für die Darstellung des rechten Koronarsystems wurde ein slab-selektiver, für die des linken ein 2-D-selektiver Inversionspuls verwendet. Die MR-Koronarangiogramme der Patienten wurden in Hinblick auf klinisch relevante Stenosen (> 50 %) analysiert und mit den Ergebnissen der Katheter-Angiografie verglichen. Ferner wurde das Signal- (SRV-) und Kontrast-zu-Rausch-Verhältnis (KRV) anhand von Signalintensitätsmessungen in den Koronararterien (coro), der Aorta (ao) und im epikardialen Fettgewebe (fett) sowie die dargestellte Gefäßlänge und die Kantenschärfe gemessen. Ergebnisse: Die Verwendung eines selektiven Inversionspulses ermöglichte die direkte Darstellung des koronaren Blutflusses sowohl im rechten als auch linken Koronarsystem. Die gemessenen SRV und KRV sowie Gefäßlänge und Kantenschärfe der Probanden (SRV coro: 28,3 ± 5,0; SRV ao: 37,6 ± 8,4; KRV coro-fett: 25,3 ± 4,5; RIVA: 128,0 cm ± 8,8; RCA: 74,6 cm ± 12,4; Schärfe: 66,6 % ± 4,8) lagen etwas über denen der Patienten (SRV coro: 24,1 ± 3,8; SRV ao: 33,8 ± 11,4; KRV coro-fett: 19,9 ± 3,3; RIVA: 112,5 cm ± 13,8; RCA: 69,6 cm ± 16,6; Schärfe: 58,9 % ± 7,9; n.s.). In der Patientenstudie wurden insgesamt 42 Gefäßsegmente evaluiert; hierbei konnten 10 klinisch relevante Stenosen richtig identifiziert werden. Schlussfolgerung: Die Modifikation einer mit einem selektiven Inversionspuls ausgestatteten MR-Koronarangiografie-Sequenz ermöglichte die Darstellung der Koronararterien bzw. des koronaren Blutflusses im rechten und auch linken Koronarsystem. Die Anwendung der Sequenz erlaubte zudem die Identifizierung von klinisch relevanten Stenosen im proximalen und mittleren Gefäßabschnitt mit hoher Genauigkeit.

Abstract

Purpose: Visualization of coronary blood flow in the right and left coronary system in volunteers and patients by means of a modified inversion-prepared bright-blood coronary magnetic resonance angiography (cMRA) sequence. Materials and Methods: cMRA was performed in 14 healthy volunteers and 19 patients on a 1.5 Tesla MR system using a free-breathing 3D balanced turbo field echo (b-TFE) sequence with radial k-space sampling. For magnetization preparation a slab selective and a 2D selective inversion pulse were used for the right and left coronary system, respectively. cMRA images were evaluated in terms of clinically relevant stenoses (< 50 %) and compared to conventional catheter angiography. Signal was measured in the coronary arteries (coro), the aorta (ao) and in the epicardial fat (fat) to determine SNR and CNR. In addition, maximal visible vessel length, and vessel border definition were analyzed. Results: The use of a selective inversion pre-pulse allowed direct visualization of the coronary blood flow in the right and left coronary system. The measured SNR and CNR, vessel length, and vessel sharpness in volunteers (SNR coro: 28.3 ± 5.0; SNR ao: 37.6 ± 8.4; CNR coro-fat: 25.3 ± 4.5; LAD: 128.0 cm ± 8.8; RCA: 74.6 cm ± 12.4; Sharpness: 66.6 % ± 4.8) were slightly increased compared to those in patients (SNR coro: 24.1 ± 3.8; SNR ao: 33.8 ± 11.4; CNR coro-fat: 19.9 ± 3.3; LAD: 112.5 cm ± 13.8; RCA: 69.6 cm ± 16.6; Sharpness: 58.9 % ± 7.9; n.s.). In the patient study the assessment of 42 coronary segments lead to correct identification of 10 clinically relevant stenoses. Conclusion: The modification of a previously published inversion-prepared cMRA sequence allowed direct visualization of the coronary blood flow in the right as well as in the left coronary system. In addition, this sequence proved to be highly sensitive regarding the assessment of clinically relevant stenotic lesions.

References

  • 1 Deshpande V S, Shea S M, Laub G. et al . 3D magnetization-prepared true-FISP: a new technique for imaging coronary arteries.  Magn Reson Med. 2001;  46 494-502
  • 2 Spuentrup E, Bornert P, Botnar R M. et al . Navigator-gated free-breathing three-dimensional balanced fast field echo (TrueFISP) coronary magnetic resonance angiography.  Invest Radiol. 2002;  37 637-642
  • 3 Kim W Y, Danias P G, Stuber M. et al . Coronary magnetic resonance angiography for the detection of coronary stenoses.  N Engl J Med. 2001;  345 1863-1869
  • 4 Spuentrup E, Katoh M, Wiethoff A J. et al . Molecular Coronary MR Imaging of Human Thrombi using EP-2104R, a Fibrin-Targeted Contrast Agent: Experimental Study in a Swine Model.  Fortschr Röntgenstr. 2007;  179 1166-1173
  • 5 Wang S J, Hu B S, Macovski A. et al . Coronary angiography using fast selective inversion recovery.  Magn Reson Med. 1991;  18 417-423
  • 6 Stuber M, Bornert P, Spuentrup E. et al . Selective three-dimensional visualization of the coronary arterial lumen using arterial spin tagging.  Magn Reson Med. 2002;  47 322-329
  • 7 Katoh M, Stuber M, Bucker A. et al . Spin labeling coronary MR angiography with steady-state free-precession (SSFP) and radial k-space sampling – initial results in healthy volunteers.  Radiology. 2005;  236 1047-1052
  • 8 Katoh M, Spuentrup E, Stuber M. et al . Inversion prepared coronary MR angiography: direct visualization of coronary blood flow.  Fortschr Röntgenstr. 2005;  177 173-178
  • 9 Stuber M, Botnar R M, Danias P G. et al . Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography.  J Am Coll Cardiol. 1999;  34 524-531
  • 10 Spuentrup E, Katoh M, Buecker A. et al . Free-breathing 3D steady-state free-precession coronary MR angiography with radial k-space sampling: Comparison with cartesian k-space sampling and cartesian gradient echo coronary MR angiography – Pilot study.  Radiology. 2004;  231 581-586
  • 11 Spuentrup E, Katoh M, Stuber M. et al . Coronary MR imaging using free-breathing 3D steady-state free precession with radial k-space sampling.  Fortschr Röntgenstr. 2003;  175 1330-1334
  • 12 Stuber M, Botnar R M, Danias P G. et al . Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations.  Radiology. 1999;  212 579-587
  • 13 Etienne A, Botnar R M, Van Muiswinkel A M. et al . ”Soap-Bubble” visualization and quantitative analysis of 3D coronary magnetic resonance angiograms.  Magn Reson Med. 2002;  48 658-666
  • 14 Botnar R M, Stuber M, Danias P G. et al . Improved coronary artery definition with T 2-weighted, free-breathing, three-dimensional coronary MRA.  Circulation. 1999;  99 3139-3148
  • 15 Brittain J H, Hu B S, Wright G A. et al . Coronary angiography with magnetization-prepared T 2 contrast.  Magn Reson Med. 1995;  33 689-696
  • 16 Pruessmann K P, Weiger M, Scheidegger M B. et al . SENSE: sensitivity encoding for fast MRI.  Magn Reson Med. 1999;  42 952-962
  • 17 Sodickson D K, Manning W J. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.  Magn Reson Med. 1997;  38 591-603
  • 18 Jahnke C, Paetsch I, Nehrke K. et al . Rapid and complete coronary arterial tree visualization with magnetic resonance imaging: feasibility and diagnostic performance.  Eur Heart J. 2005;  26 2313-2319
  • 19 Sakuma H, Ichikawa Y, Suzawa N. et al . Assessment of coronary arteries with total study time of less than 30 minutes by using whole-heart coronary MR angiography.  Radiology. 2005;  237 316-321
  • 20 Ohnesorge B M, Hofmann L K, Flohr T G. et al . CT for imaging coronary artery disease: defining the paradigm for its application.  Int J Cardiovasc Imaging. 2005;  21 85-104

Dr. Marcus Katoh

Department of Diagnostic and Interventional Radiology, University Hospital Saarland Homburg

Kirrberger Straße

66421 Homburg

Germany

Phone: ++ 49/68 41/1 62 46 00

Fax: ++ 49/68 41/1 62 46 96

Email: marcus.katoh@uks.eu