Thorac Cardiovasc Surg 2009; 57(6): 324-328
DOI: 10.1055/s-0029-1185766
Original Cardiovascular

© Georg Thieme Verlag KG Stuttgart · New York

Intraaortic Balloon Pumping in Patients with Right Ventricular Insufficiency after Cardiac Surgery: Parameters to Predict Failure of IABP Support[*]

U. Boeken1 , P. Feindt1 , J. Litmathe1 , M. Kurt1 , E. Gams1
  • 1Department of Thoracic and Cardiovascular Surgery, Heinrich-Heine-University Hospital, Duesseldorf, Germany
Further Information

Publication History

received March 1, 2009

Publication Date:
25 August 2009 (online)

Abstract

Background: The indications for intra-aortic balloon pump (IABP) in the case of a failing right ventricle after operations with extracorporeal circulation (ECC) are still discussed controversially. We investigated the benefit of IABP in patients with a predominantly right ventricular dysfunction after ECC. Additionally, we wanted to identify early and easily available prognostic markers for outcome in all patients receiving IABP support. Patients and Methods: Between 1/2004 and 1/2008, 4550 patients underwent cardiac surgical procedures with ECC, 223 of whom (4.9 %) had an IABP inserted intra- or postoperatively (group 1). 79 of these patients were treated intraoperatively with IABP for early postoperative low cardiac output syndrome (LCOS) characterized by predominantly right ventricular failure (RV group). Clinical data and hemodynamic variables were recorded perioperatively. Multiple potential markers of mortality and postoperative complications were analyzed statistically, especially with regard to their predictive ability. Results: 68 % of all IABP patients were successfully weaned from IABP support and 63 % survived to hospital discharge. In the RV group, cardiac index (CI) and mean arterial pressure (MAP) increased (CI 1.8 ± 0.2 to 2.8 ± 0.2, MAP 53 ± 10 to 73 ± 8, p < 0.05) within 1 hour after IABP, whereas central venous pressure (CVP) and pulmonary artery wedge pressure (PAWP) decreased (p < 0.05). 59 patients in the RV group (75 %) could be weaned from IABP successfully and 69 % survived to hospital discharge. Serum lactate of more than 11 mmol/L in the first 10 hours of IABP support predicted a 100 % mortality. A base deficit of more than 12 mmol/L, mean arterial pressure less than 55 mmHg, urine output of less than 50 ml/h for 2 hours, and dose of epinephrine or norepinephrine of more than 0.4 mg/kg/min were other highly predictive prognostic markers. Furthermore, multivariate analysis showed that patients with a left atrial pressure > 17 mmHg or a mixed venous saturation (SVO2) < 65 % had poor outcomes. Conclusions: In patients with IABP support for postcardiotomy cardiogenic shock, elevated serum lactate, elevated base deficit, hypotension, oliguria and large vasopressor doses are all predictors of mortality. In these patients, the use of another mechanical assist device should be considered in good time. Our study additionally shows that LCOS caused by predominantly right ventricular failure – particularly after CABG – may be an additional indication for IABP.

1 The results of this paper were presented in part during the 5th joint meeting of the German, Austrian and Swiss Societies of Thoracic- and Cardiovascular Surgery, February 17–20, 2008 in Insbruck/Austria as oral presentation.

References

  • 1 Arafa O E, Deiran O R, Andersen K, Fosse E, Simonsen S, Svennevig J L. Intraaortic balloon pumping for predominantly right ventricular failure after heart transplantation.  Ann Thorac Surg. 2000;  70 1587-1593
  • 2 Barzaghi N, Olivei M, Minzioni G, Degani A, Braschi A, Vigano M. ECMO and inhaled nitric oxide for cardiopulmonary failure after heart retransplantation.  Ann Thorac Surg. 1997;  63 533-535
  • 3 Bigatello L M, Hurford W E, Kacmarek R M, Roberts J D, Zapol W M. Prolonged inhalation of low concentrations of nitric oxide in patients with severe adult respiratory distress syndrome.  Anesthesiology. 1994;  80 761-770
  • 4 Boehmer J P, Popjes E. Cardiac failure: mechanical support strategies.  Crit Care Med. 2006;  34 268-277
  • 5 Chen J M, Levin H R, Rose E A, Addonizio L J, Landry D W, Sistino J J, Michler R E, Oz M C. Experience with right ventricular assist devices for perioperative right sided circulatory failure.  Ann Thorac Surg. 1996;  61 305-310
  • 6 Creswell L L, Rosenbloom M, Cox J L. Intra-aortic balloon counterpulsation patterns of usage and outcome in cardiac surgery patients.  Ann Thorac Surg. 1992;  54 11-20
  • 7 Damiano Jr R J, La Follette Jr P, Cox J L, Lowe J E, Santamore W P. Significant left ventricular contribution to right ventricular systolic function.  Am J Physiol. 1991;  261 H1514-H1524
  • 8 Darrah W C, Sharpe M D, Guiraudon G M, Neal A. Intraaortic balloon counterpulsation improves right ventricular failure resulting from pressure overload.  Ann Thorac Surg. 1997;  64 17-24
  • 9 Geiran O, Lindberg H, Øvrum E, Frøysaker T. Experiences with closed chest, temporary atrio-atrial, ventricular bypass with a centrifugal pump after open heart surgery.  Eur J Cardiothorac Surg. 1989;  3 44-51
  • 10 Girard C, Durand P G, Vedrinne C, Pannetier J C, Estanove S, Falke K, Adnot S, Lemaire F. Inhaled nitric oxide for right ventricular failure after heart transplantation.  J Cardiothorac Vasc Anesth. 1993;  7 481-485
  • 11 Hausmann H, Potapov E V, Koster A, Krabatsch T, Stein J, Yeter R, Kukucka M, Sodian R, Kuppe H, Hetzer R. Prognosis after the implantation of an intra-aortic balloon pump in cardiac surgery calculated with a new score.  Circulation. 2002;  106 (1) 203-206
  • 12 Hausmann H, Topp H, Siniawski H, Holz S, Hetzer R. Decision-making in end-stage coronary artery disease: revascularization or heart transplantation.  Ann Thorac Surg. 1997;  64 1296-1302
  • 13 Healy D G, Veerasingam D, Wood A E. EuroSCORE: useful in directing preoperative intra-aortic balloon pump placement in cardiac surgery?.  Heart Surg Forum. 2006;  9 E893-E896
  • 14 Kantrowitz A. Origins of intraaortic balloon pumping.  Ann Thorac Surg. 1990;  50 672-674
  • 15 Kopman E A, Ramirez-Inawat R C. Intra-aortic balloon counterpulsation for right heart failure.  Anesth Analg. 1980;  59 74-76
  • 16 Litmathe J, Feindt P, Boeken U, Gams E. Mechanical heart support using intraaortic balloon counterpulsation. A retrospective view and current perspectives.  Acta Cardiol. 2003;  59 (2) 159-164
  • 17 Loebe M, Weng Y, Henning E. Long-term mechanical circulatory support: the Berlin experience. Hetzer R, Henning E, Loebe M Mechanical circulatory support. Darmstadt; Steinkopff 1997: 150-154
  • 18 Maccioli G A, Lucas W J, Norfleet E A. The intra-aortic balloon pump: a review.  J Cardiothorac Anesth. 1988;  2 365-373
  • 19 McEnany T M, Kay H R, Buckley M J, Daggett W M, Erdmann A J, Mundth E D, Rao R S, DeToeuf J, Austen W G. Clinical experience with intra-aortic balloon pump support in 782 patients.  Circulation. 1978;  58 1124-1132
  • 20 Pennington D G, Swartz M, Codd J E, Merjavy J P, Kaiser G C. Intra-aortic balloon pumping in cardiac surgical patients: a nine year experience.  Ann Thorac Surg. 1983;  36 125-131
  • 21 Santa-Cruz R A, Cohen M G, Ohman E M. Aortic counterpulsation: a review of the hemodynamic effects and indications for use.  Catheter Cardiovasc Interv. 2006;  67 68-77
  • 22 Trost J C, Hillis L D. Intra-aortic balloon counterpulsation.  Am J Cardiol. 2006;  97 1391-1398
  • 23 Vlahakes G J, Turley K, Hoffman J I E. The pathophysiology of failure in acute right ventricular hypertention: hemodynamic and biochemical correlations.  Circulation. 1981;  63 87-95
  • 24 Yamaguchi S, Harasawa H, Li K S, Santamore W P. Comparative significance in systolic ventricular interaction.  Cardiovasc Res. 1991;  25 774-783

1 The results of this paper were presented in part during the 5th joint meeting of the German, Austrian and Swiss Societies of Thoracic- and Cardiovascular Surgery, February 17–20, 2008 in Insbruck/Austria as oral presentation.

Dr. PD Udo Boeken

Department of Thoracic and Cardiovascular Surgery
University Hospital

Moorenstraße 5

40225 Duesseldorf

Germany

Phone: + 49 21 18 11 69 80

Fax: + 49 21 18 11 83 33

Email: boeken@uni-duesseldorf.de