Pneumologie 2011; 65(7): 401-405
DOI: 10.1055/s-0030-1256252
Übersicht

© Georg Thieme Verlag KG Stuttgart · New York

Krankheiten erriechen? Eine kurze Übersicht über elektronische Nasen

Smelling Diseases? A Short Review on Electronic NosesA.  R.  Koczulla1 , A.  Hattesohl1 , H.  Biller2 , J.  Hofbauer3 , J.  Hohlfeld2 , C.  Oeser4 , C.  Gessner4 , C.  Vogelmeier1 , J.  I.  Baumbach5 , H.  Wirtz4 [*] , R.  A.  Jörres3 [*]
  • 1Klinik für Innere Medizin, Schwerpunkt Pneumologie, Philipps-Universität Marburg
  • 2Abteilung Klinische Atemwegsforschung, Fraunhofer Institut für Toxikologie und Experimentelle Medizin, Hannover
  • 3Institut und Poliklinik für Arbeits-, Sozial- und Umweltmedizin, Ludwig-Maximilians-Universität München
  • 4Abteilung Pneumologie, Department Innere Medizin, Universität Leipzig
  • 5Abteilung Klinische Diagnostik, KIST Europe, Campus E71, Saarbrücken
Further Information

Publication History

eingereicht 23. 12. 2010

akzeptiert nach Revision 1. 2. 2011

Publication Date:
16 March 2011 (online)

Zusammenfassung

Nichtinvasive Atemwegsuntersuchungen stellen eine vielversprechende Entwicklung in der pulmonalen Diagnostik der letzten 15 Jahre dar. Neben der Messung des exhalierten Stickstoffmonoxids (FeNO) werden für wissenschaftliche Fragestellungen vermehrt breiter gespannte, technisch diffizilere Verfahren wie elektronische Nasen (EN) verwendet. EN zielen darauf ab, das menschliche Geruchsorgan teilweise zu imitieren. Verschiedene Typen von EN werden zurzeit für wissenschaftliche Fragestellungen getestet. Neben Geräten, die auf Messung der Ionenmobilität beruhen, oder Massenspektrometern werden Geräte verwendet, die auf einer Auswahl von Polymer-Sensoren beruhen, die volatile organische Komponenten (VOCs) abhängig von Größe, Struktur, Polarität und Protonenaffinität binden und so kombinierte Signalmuster erzeugen, ohne dass in der Regel Einzelkomponenten identifiziert werden. Die Analysen erfolgen dabei über eine Mustererkennung. Einige Verfahren, zum Beispiel die Ionenmobilitätspektroskopie (IMS) oder Massenspektroskopie (MS), ermöglichen auch eine direkte Bestimmung von Komponenten. Vielfach sind allerdings die substanzspezifischen Muster noch nicht für alle vorkommenden Analyte in Datenbanken hinterlegt, sodass auch hier häufig zur Differenzierung eine Mustererkennung verwendet wird. In der Medizindiagnostik stehen der nichtinvasive Zugang und die „onsite” Verfügbarkeit dieser Verfahren im Vordergrund. Von einem Routineeinsatz ist man noch entfernt, jedoch weisen die Ergebnisse auf vielversprechende Anwendungsmöglichkeiten hin. In der folgenden Übersicht wollen wir daher die Verfahren kurz auf dem derzeitigen Wissensstand vorstellen.

Abstract

Non-invasive pulmonary diagnostics is a promising and interesting field in respiratory medicine. Beside exhaled breath condensate, there is an increasing interest in alternative and faster techniques such as electronic noses (EN). EN aim to mimic or improve the sense of smelling. Different types of EN have been employed in research so far. In addition to ion mobility spectrometry and mass spectrometry, ENs that consist of various biopolymer sensors for the sensing of volatile organic compounds (VOCs) have been tested. VOCs bind to the sensors depending on size, structure, hydrogen binding and polarity. This leads to physical alterations, e. g., swelling resulting in a change of resistance. The smell print represents composite patterns in contrast to single compounds, and the distinction between different categories is achieved by pattern recognition algorithms. Other types of EN like mass spectrometry and ion mobility spectrometry are capable of identifying even single analyte fractions provided that their characteristics have been saved in data repositories. The non-invasive nature, onsite availability and relatively cheap sampling are advantages of ENs that underly the increasing interest in their use for medical purposes. Some promising results have already been published. This review aims to describe the state of the art in brief form.

Literatur

  • 1 Lewis N S. Comparisons between mammalian and artificial olfaction based on arrays of carbon black-polymer composite vapor detectors.  Acc Chem Res. 2004;  37 663-672
  • 2 Peris M, Escuder-Gilabert L. A 21st century technique for food control: electronic noses.  Anal Chim Acta. 2009;  638 1-15
  • 3 Marti M P, Boque R, Riu M et al. Fast screening method for determining 2,4,6-trichloroanisole in wines using a headspace-mass spectrometry (HS-MS) system and multivariate calibration.  Anal Bioanal Chem. 2003;  376 497-501
  • 4 Marti M P, Mestres M, Sala C et al. Solid-phase microextraction and gas chromatography olfactometry analysis of successively diluted samples. A new approach of the aroma extract dilution analysis applied to the characterization of wine aroma.  J Agric Food Chem. 2003;  51 7861-7865
  • 5 Dragonieri S, Schot R, Mertens B J et al. An electronic nose in the discrimination of patients with asthma and controls.  J Allergy Clin Immunol. 2007;  120 856-862
  • 6 Dragonieri S, Annema J T, Schot R et al. An electronic nose in the discrimination of patients with non-small cell lung cancer and COPD.  Lung Cancer. 2009;  64 166-170
  • 7 Fens N, Zwinderman A H, van der Schee M P et al. Exhaled breath profiling enables discrimination of chronic obstructive pulmonary disease and asthma.  Am J Respir Crit Care Med. 2009;  180 1076-1082
  • 8 Westhoff M, Litterst P, Freitag L et al. Ion mobility spectrometry for the detection of volatile organic compounds in exhaled breath of patients with lung cancer: results of a pilot study.  Thorax. 2009;  64 744-748
  • 9 Baumbach J I, Eiceman G A. Ion mobility spectrometry: arriving on site and moving beyond a low profile.  Appl Spectrosc. 1999;  53 338A-355A
  • 10 Westhoff M, Litterst P, Freitag L et al. Ion mobility spectrometry in the diagnosis of sarcoidosis: results of a feasibility study.  J Physiol Pharmacol. 2007;  58 Suppl 5 (Pt 2) 739-751
  • 11 Lin J L, Bonnichsen M H, Nogeh E U et al. Proteomics in detection and monitoring of asthma and smoking-related lung diseases.  Expert Rev Proteomics. 2010;  7 361-372
  • 12 Mieth M, Kischkel S, Schubert J K et al. Multibed needle trap devices for on site sampling and preconcentration of volatile breath biomarkers.  Anal Chem. 2009;  81 5851-5857
  • 13 Mieth M, Schubert J K, Groger T et al. Automated needle trap heart-cut GC/MS and needle trap comprehensive two-dimensional GC/TOF-MS for breath gas analysis in the clinical environment.  Anal Chem. 2010;  82 2541-2551
  • 14 Hofbauer J, Dressel H, Seissler J. Analyse der Ausatemluft mittels Elektronischer Nase bei Patienten mit Diabetes mellitus.  Pneumologie. 2010;  64 S206

1 Herr Wirtz und Herr Jörres haben äquivalenten Anteil an der Arbeit.

Dr. A. R. Koczulla

Universitätsklinikum Gießen und Marburg
Abteilung für Pulmonologie
Standort Marburg

Baldingerstraße 1
35042 Marburg

Email: koczulla@med.uni-marburg.de

    >