Literatur
-
1
Khraisat A, Stegaroiu R, Nomura S et al.
Fatigue resistance of two implant/abutment joint designs.
J Prosthet Dent.
2001;
88
604-610
-
2
Dittmer M, Dittmer S, Borchers L et al.
Influence of the interface on the yield force of the implant-abutment complex before and after cyclic mechanical loading.
J Prosthodont Res.
2011;
DOI: 10.1016/j.jpor.2011.02.002
[Epub ahead of print]
-
3
Zarone F, Sorrentino R, Traini T et al.
Fracture resistance of implant-supported screw- versus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis.
Dent Mater.
2007;
23
296-301
-
4
Al-Omari W M, Shadid R, Abu-Naba'a L et al.
Porcelain fracture resistance of screw-retained, cemented, and screw-cement-retained implant-supported metal ceramic posterior crowns.
J Prosthodont.
2010;
19
263-273
-
5
Klug S, Eisenburger M.
The effect of guidance elements on the rotation of cast crowns during cementation.
Int J Prosthodont.
2010;
23
347-349
-
6 Geis-Gersdorfer J, in Eichner K, Kappert H F Hrsg.. Zahnärztliche Werkstoffe und ihre Verarbeitung. Stuttgart: Thieme; 2005
-
7 Körber K. Physik und Chemie zahnärztlicher Werkstoffe. In: Körber K, Ludwig K Zahnärztliche Werkstoffkunde und Technologie. Stuttgart: Thieme; 1993
-
8
Manicone P F, Rossi Iommetti P, Raffaelli L.
An overview of zirconia ceramics: basic properties and clinical applications.
J Dent.
2007;
48
229-236
-
9
Marx R.
Moderne keramische Werkstoffe für ästhetische Restaurationen – Verstärkung und Bruchzähigkeit.
Dtsch Zahnärztl Z.
1993;
48
229-236
-
10
Luthardt R G, Herold V, Sandkuhl O et al.
Kronen aus Hochleistungskeramik. Zirkondioxid-Keramik, ein neuer Werkstoff in der Kronenprothetik.
Dtsch Zahnärztl Z.
1998;
53
280-285
-
11
Andersson B, Taylor A, Lang B R et al.
Alumina ceramic implant abutments used for single-tooth replacement: a prospective 1 to 3 year multicenter study.
Int J Prosthodont.
2001;
14
432-438
-
12
Kerstein R B, Radke J.
A comparison of fabrication precision and mechanical reliability of 2 zirconia implant abutments.
Int J Oral Maxillofac Implants.
2008;
23
(6)
1029-1036
-
13
Nakamura K, Kanno T, Milleding P et al.
Zirconia as a dental implant abutment material: a systematic review.
Int J Prosthodont.
2010;
23
(4)
299-309
-
14
Truninger T C, Stawarczyk B, Leutert C R et al.
Bending moments of zirconia and titanium abutments with internal and external implant-abutment connections after aging and chewing simulation.
Clin Oral Implants Res.
2011;
DOI: 10.1111/j.1600-0501.2010.02141.x.
-
15
Yüzügüllü B, Avci M.
The Implant-Abutment Interface of Aluminia and Zirconia Abutments.
Clin Implant Dent Relat Res.
2008;
10
(2)
113-121
DOI: 10.1111/j.1708-8208.2007.00071.x
-
16
Sailer I, Philipp A, Zembic A et al.
A systematic review of the performance of ceramic and metal implant abutments supporting fixed implant reconstructions.
Clin Oral Implants Res.
2009;
4
4-31
-
17
Sorrentino R, De Simone G, Tete S et al.
Five-year prospective clinical study of posterior three-unit zirconia-bases fixed dental prostheses.
Clin Oral Investig.
2011;
DOI: 10.1007/s00784-011-0575-2
-
18
Heuer W, Kettenring A, Stumpp S N et al.
Metagenomic analysis of the peri-implant and periodontal microflora in patients with clinical signs of gingivitis or mucositis.
Clin Oral Investig.
2011;
DOI: 10.1007/s00784-011-0561-8
[Epub ahead of print]
-
19
Machtei E E, Oved-Peleg E, Peled M.
Comparison of clinical, radiographic and immunological parameters of teeth and different dental implant platforms.
Clin Oral Implants Res.
2006;
17
(6)
658-665
-
20
Pjetursson B E, Brägger U, Lang N P et al.
Comparison of survival and complication rates of tooth-supported fixed dental prostheses (FDPs) and implant-supported FDPs and single crowns (SCs).
Clin Oral Implants Res.
2007;
18
97-113
-
21
Vigolo P, Givani A, Majzoub Z et al.
Cemented versus screw-retained implant-supported single-tooth crowns: a 4-year prospective clinical study.
Int J Oral Maxillofac Implants.
2004;
19
(2)
260-265
-
22
Raap U, Stiesch M, Reh H et al.
Investigation of contact allergy to dental metals in 206 patients.
Contact Dermatitis.
2009;
60
(6)
339-343
-
23
Linkevicius T, Apse P.
Influence of abutment material on stability of peri-implant tissues: a systematic review.
Int J Oral Maxillofac Implants.
2008;
23
(3)
449-456
-
24
Degidi M, Artese L, Scarano A et al.
Inflammatory infiltrate, microvessel density, nitric oxide synthase expression, vascular endothelial growth factor expression, and proliferative activity in peri-implant soft tissues around titanium and zirconium oxide healing caps.
J Periodontol.
2006;
77
(1)
73-80
-
25
Vigolo P, Givani A, Majzoub Z et al.
A 4-year prospective study to assess peri-implant hard and soft tissues adjacent to titanium versus gold-alloy abutments in cemented single implant crowns.
J Prosthodont.
2006;
15
(4)
250-256
-
26
Bremer F, Grade S, Koherst P et al.
In vivo biofilm formation on different dental ceramics.
Quintessence Int.
2011;
42
(7)
565-574
-
27
Lima E M, Koo H, Vacca Smith A M et al.
Adsorption of salivary and serum proteins, and bacterial adherence on titanium and zirconia ceramic surfaces.
Clin Oral Implants Res.
2008;
19
(8)
780-785
-
28
Auschill T M, Arweiler N B, Brecx M et al.
The effect of dental restorative materials on dental biofilm.
Eur J Oral Sci.
2002;
110
(1)
48-53
-
29
Fadeeva E, Truong V K, Stiesch M et al.
Bacterial Retention on Superhydrophobic Titanium Surfaces Fabricated by Femtosecond Laser Ablation.
Langmuir.
2011;
2
DOI: 10.1021/Lo.1046079
[Epub ahead of print]
-
30
Heuer W, Winkel A, Kohorst P et al.
Assessment of the Cytocompatibility of Poly-(N-hexylvinylpyridium) used as an Antibacterial Implant-Coating.
Adv Eng Mater.
2011;
DOI: 10.1002/adem.201080030
Prof. Dr. med. dent. Meike Stiesch
Medizinische Hochschule Hannover
Klinik für Zahnärztliche Prothetik und Biomedizinische Werkstoffkunde
Carl-Neuberg-Str. 1
30625 Hannover
Telefon: 05 11/5 32-47 73
Fax: 05 11/5 32-47 90
eMail: Stiesch.Meike@mh-hannover.de