Krankenhaushygiene up2date, Table of Contents Krankenhaushygiene up2date 2012; 07(03): 199-212DOI: 10.1055/s-0032-1310268 Technische und bauliche Aspekte © Georg Thieme Verlag KG Stuttgart · New York Raumlufttechnik im OP und postoperative Wundinfektionen. Was gibt es Neues? Petra Gastmeier , Christian Brandt Recommend Article Abstract Buy Article All articles of this category Full Text References Literatur 1 Richter-Kuhlmann E. Endoprothesenregister: „Ganze Produktgruppen werden vom Markt verschwinden“. Dtsch Arztebl 2008; 105: A16 2 ECDC Report Surveillance of Surgical Site Infections. 2011; http://ecdc.europe.eu/en/activities/surveillance/HAI/about-HAI-Net/Pages/SSI.aspx 3 Kurtz S, Lau E, Schmier J et al. Infection burden for hip and knee arthroplasty in the United States. J Arthroplasty 2008; 23: 984-991 4 Kappstein I. Die Luft als Erregerreservoir für postoperative Wundinfektionen. Teil 1: Welche Aussagen lassen die klinischen Studien zu?. Krankenh hyg up2date 2007; 2: 53-68 5 Lidwell O, Lowbury E, Whyte W et al. Effect of ultraclean air in operating rooms on deep sepsis in the joint after total hip or knee replacement: a randomised study. Br Med J 1982; 285: 10-14 6 Lidwell OM. Infection and failure rates: Is my infection (failure) rate too high?. J Hosp Infect 1991; 18: 255-260 7 van Griethausen A, Soies-van Rooijen N, Hoogenboom-Verdegaal A. Surveillance of wound infections and a new theatre: unexpected lack of improvement. J Hosp Infect 1996; 34: 99-106 8 Pasquarella C, Sansebastiano G, Ferretti S et al. A mobile laminar airflow unit to reduce air bacterial contamination at surgical area in a conventionally ventilated operating theatre. J Hosp Infect 2007; 66: 313-319 9 Rodridues da Costa A, Kothari A, Bannister G et al. Investigating bacterial growth in surgical theatres: establishing the effect of laminar airflow on bacterial growth on plastic, metal and wood surfaces. Ann R Coll Surg Engl 2008; 90: 417-419 10 CDC/HICPAC. Guidelines for environmental infection control in health care facilities. MMWR Morb Mortal Wkly Rep 2003; 52: 1-42 11 Anforderungen der Hygiene bei Operationen und anderen invasiven Eingriffen. Bundesgesundheitsbl 2000; 43: 644-648 12 Cacciari P, Giannoni R, Marcelli E et al. Cost evaluation of a ventilation system for operating theatre: an ultraclean design versus a conventional one. Ann Ig 2004; 16: 803-809 13 Brandt C, Hott U, Sohr D et al. Operating room ventilation with laminar airflow shows no protective effect on the surgical site infection rate in orthopedic and abdominal surgery. Ann Surg 2008; 248: 695-700 14 Kurz A, Sessler DI, Lenhardt R. Perioperative normothermia to reduce the incidence of surgical-wound infection and shorten hospitalization. N Engl J Med 1996; 334: 1209-1215 15 Melling A, Ali B, Scott E et al. Effects of preoperative warming on the incidence of wound infection after clean surgery: a randomised controlled trial. Lancet 2001; 358: 876-880 16 McGovern P, Albrecht M, Belani K et al. Forced-air warming and ultra-clean ventilation do not mix: an investigation of theatre ventilation, patient warming and joint replacement infection in orthopaedics. J Bone Joint Surg Br 2011; 93: 1537-1544 17 Lipsett P. Do we really need laminar flow ventilation in the operating room to prevent surgical site infections?. Ann Surg 2008; 248: 701-703 18 Assadian O, Kuelpmann R, Zhumadilova A et al. Protective effect of HEPA-filtered operating room air ventilation with or without laminar airflow on surgical site infections. Ann Surg 2009; 250: 659-660 19 Brandt C, Rüden H, Gastmeier P. Protective effect of HEPA-filtered operating room air ventilation with or without laminar airflow on surgical site infections. Ann Surg 2009; 250: 660 20 Kramer A, Külpmann R, Wille F et al. Infektiologische Bedeutung von Raumlufttechnischen Anlagen (RLTA) in Operations- und Eingriffsräumen. Zentralbl Chirurgie 2010; 135: 11-17 21 Breier A-C, Brandt C, Sohr D et al. Laminar airflow and the size of the ceiling size: No impact on infection rates following hip and knee prosthesis. Infect Control Hosp Epidemiol 2011; 32: 1097-1102 22 Taylor G, Bannister G. Infection and interposition between ultraclean air source and wound. J Bone Joint Surg Br 1993; 75: 544-548 23 Salvati E, Robinson R, Zeno S et al. Infection rates after 3175 total hip and knee replacements performed with and without a horizontal unidirectional filtered air-flow system. J Bone Joint Surg Am 1982; 64: 525-535 24 Hooper G, Rothwell A, Frampton C et al. Does the use of laminar airflow and space suits reduce early deep infection after total hip and knee replacement?. J Bone Joint Surg 2011; 93: 85-90 25 Engesaeter L, Lie S, Espehaug B et al. Antibiotic prophylaxis in total hip arthroplasty. Acta Orthop Scand 2003; 74: 644-651 26 Miner A, Losina E, Katz J et al. Deep infection after total knee replacement: impact of laminar airflow systems and body exhaust suits in the modern operating room. Infect Control Hosp Epidemiol 2007; 28: 222-226 27 Kakwani R, Yohannan D, Wahab K. The effect of laminar air-flow on the results of Austin-Moore hemiarthropalsty. Injury 2007; 38: 820-823 28 Gastmeier P, Breier A-C, Brandt C. Influence of laminar airflow on prosthetic joint infections: a systematic review. J Hosp Infect 2012; 81: 73-78 29 Humphreys H. Surgical site infection, ultraclean ventilated operating theatres and prosthetic joint surgery: where now?. J Hosp Infect 2012; 81: 71-72