J Knee Surg 2012; 25(05): 407-410
DOI: 10.1055/s-0032-1313756
Original Article
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Effect of Flexion and Rotation on Measures of Coronal Alignment after TKA

Arun Kannan
1   Department of Orthopaedics, Malabar Orthopaedic Clinic, Windsor, Victoria, Australia
,
Gabrielle Hawdon
1   Department of Orthopaedics, Malabar Orthopaedic Clinic, Windsor, Victoria, Australia
,
Stephen John McMahon
1   Department of Orthopaedics, Malabar Orthopaedic Clinic, Windsor, Victoria, Australia
2   Department of Orthopaedics, Monash University, Victoria, Australia
› Author Affiliations
Further Information

Publication History

01 September 2011

27 November 2011

Publication Date:
15 May 2012 (online)

Abstract

Attainment of a neutral mechanical axis is one of the primary goals in total knee arthroplasty (TKA). The accuracy of the procedure is evaluated by measuring the hip-knee-ankle angle (HKAA) on long leg radiographs. Rotation of the lower limb and knee flexion could possibly affect the HKAA measured on plain radiographs. In this study, a TKA was performed on a saw-bone model of the lower limb. Long leg radiographs from the femoral head to the ankle were obtained after sequentially varying the alignment of the knee model in 5-degree increments of flexion and rotation, from 0 to 20 degrees. Flexion or external rotation alone, up to 20 degrees changed the HKAA by no more than 1 degree. A combination of flexion and external rotation progressively altered the HKAA. The HKAA was altered by 5 degrees at a combination of 15- or 20-degree flexion and 20-degree external rotation. While flexion or external rotation alone had little effect on the HKAA, a combination of the two altered it substantially.

 
  • References

  • 1 Jeffery RS, Morris RW, Denham RA. Coronal alignment after total knee replacement. J Bone Joint Surg Br 1991; 73 (5) 709-714
  • 2 D'Lima DD, Chen PC, Colwell Jr CW. Polyethylene contact stresses, articular congruity, and knee alignment. Clin Orthop Relat Res 2001; 392 (392) 232-238
  • 3 D'Lima DD, Hermida JC, Chen PC, Colwell Jr CW. Polyethylene wear and variations in knee kinematics. Clin Orthop Relat Res 2001; 392 (392) 124-130
  • 4 Werner FW, Ayers DC, Maletsky LP, Rullkoetter PJ. The effect of valgus/varus malalignment on load distribution in total knee replacements. J Biomech 2005; 38 (2) 349-355
  • 5 Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA. The effect of alignment and BMI on failure of total knee replacement. J Bone Joint Surg Am 2011; 93 (17) 1588-1596
  • 6 Parratte S, Pagnano MW, Trousdale RT, Berry DJ. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am 2010; 92 (12) 2143-2149
  • 7 Ensini A, Catani F, Leardini A, Romagnoli M, Giannini S. Alignments and clinical results in conventional and navigated total knee arthroplasty. Clin Orthop Relat Res 2007; 457: 156-162
  • 8 Chauhan SK, Scott RG, Breidahl W, Beaver RJ. Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Joint Surg Br 2004; 86 (3) 372-377
  • 9 Bäthis H, Perlick L, Tingart M, Lüring C, Zurakowski D, Grifka J. Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 2004; 86 (5) 682-687
  • 10 Martin A, Wohlgenannt O, Prenn M, Oelsch C, von Strempel A. Imageless navigation for TKA increases implantation accuracy. Clin Orthop Relat Res 2007; 460: 178-184
  • 11 Hafez MA, Chelule KL, Seedhom BB, Sherman KP. Computer-assisted total knee arthroplasty using patient-specific templating. Clin Orthop Relat Res 2006; 444: 184-192
  • 12 Lizaur A, Marco L, Cebrian R. Preoperative factors influencing the range of movement after total knee arthroplasty for severe osteoarthritis. J Bone Joint Surg Br 1997; 79 (4) 626-629
  • 13 Wevers HW, Siu DW, Cooke TD. A quantitative method of assessing malalignment and joint space loss of the human knee. J Biomed Eng 1982; 4 (4) 319-324
  • 14 Wright JG, Treble N, Feinstein AR. Measurement of lower limb alignment using long radiographs. J Bone Joint Surg Br 1991; 73 (5) 721-723
  • 15 Lonner JH, Laird MT, Stuchin SA. Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties. Clin Orthop Relat Res 1996; (331) 102-106
  • 16 Radtke K, Becher C, Noll Y, Ostermeier S. Effect of limb rotation on radiographic alignment in total knee arthroplasties. Arch Orthop Trauma Surg 2010; 130 (4) 451-457