Subscribe to RSS
DOI: 10.1055/s-0033-1354373
Development of Validated Stability Indicating Assay Method for Simultaneous Estimation of Metformin Hydrochloride and Vildagliptin by RP-HPLC
Publication History
received 05 July 2013
accepted 27 July 2013
Publication Date:
19 September 2013 (online)
Abstract
A simple, precise and stability-indicating HPLC method was developed and validated for the simultaneous determination of metformin hydrochloride (MET) and vildagliptin (VLG) in pharmaceutical dosage forms. The method involves use of easily available inexpensive laboratory reagents. The separation was achieved on Grace Cyano column (250 mm×4.6 mm) 5 µm with isocratic flow. The mobile phase was pumped at a flow rate of 1.0 mL/min, consisted of 25 mM ammonium bicarbonate buffer and acetonitrile (65:35, v/v). The UV detection was carried out at 207 nm. A linear response was observed over the concentration range of 25–125 µg/mL for MET and 50–250 µg/mL for VLG respectively. Limit of detection and limit of quantification for MET were 0.36 µg/mL and 1.22 µg/mL, and for VLG were 0.75 µg/mL and 2.51 µg/mL respectively. The method was successfully validated in accordance to ICH guidelines acceptance criteria for specificity, linearity, accuracy, precision, robustness, and system suitability. Individual drugs (MET and VLG) were exposed to thermal, photolytic, hydrolytic and oxidative stress conditions. The resultant stressed samples were analyzed by the proposed method. The method gave high resolution among the degradation products and the analytes. The peak purity of analyte peak in the stressed samples was confirmed by photo diode array detector. The proposed method was successfully applied for the quantitative analysis of MET and VLG in tablet dosage form, which will help to improve quality control and contribute to stability studies of pharmaceutical tablets containing these drugs.
-
References
- 1 O’Neil MJ, Smith A, Heckelman PE et al. The merck index an encyclopedia of chemical, drugs, and biologicals. 14 ed. Merck & Co; New Jersey: 2006
- 2 Bolli G, Dotta F, Colin L et al. Comparison of vildagliptin and pioglitazone in patients with type 2 diabetes inadequately controlled with metformin. Diabetes Obes Metab 2009; 11: 589-595
- 3 Malleswararao CSN, Suryanarayana MV, Mukkanti K. Simultaneous Determination of Sitagliptin Phosphate Monohydrate and Metformin Hydrochloride in Tablets by a Validated UPLC Method. Sci Pharm 2012; 80: 139-152
- 4 Shyamala M, Mohideen S, Satyanarayana T et al. Validated RP-HPLC for simultaneous estimation of sitagliptin phosphate and metformin hydrochloride in tablet dosage form. American Journal of PharmTech Research 2011; 1: 93-101
- 5 Diwan PV, Surendra Kumar N, Sanayaima H et al. Development of stability indicating RP-HPLC method for the determination of sitagliptin phosphate and metformin hydrochloride in tablet dosage form. International Journal of Pharmacy & Industrial Research 2012; 2: 283-290
- 6 Moore KA, Levine B, Titus J et al. Analysis of Metformin in Antemortem Serum and Post-mortem Specimens by a Novel HPLC Method and Application to an Intoxication Case. J Anal Toxicol 2003; 27: 592-594
- 7 Porta V, Schramm SG, Kano EK et al. HPLC-UV determination of metformin in human plasma for application in pharmacokinetics and bioequivalence studies. J Pharm Biomed Anal 2008; 46: 143-147
- 8 Joshi SS, Nahire RR, Shastri NR et al. Validated Stability-Indicating RP-HPLC UV Method for Simultaneous Determination of Metformin and Repaglinide. Acta Chromatographica 2012; 24: 419-432
- 9 AbuRuz S, Millership J, McElnay J et al. The development and validation of liquid chromatography method for the simultaneous determination of metformin and glipizide, gliclazide, glibenclamide or glimperide in plasma. J Chromatogr B 2005; 817: 277-286
- 10 Raja P, Thejaswini JC, Gurupadayya BM et al. Stability indicating RP-HPLC method for simultaneous determination of anti diabetic drugs. J Pharm Res 2012; 5: 1791-1794
- 11 Sumithra M, Shanmugasudaram MRP, Sankar ASK et al. Development of rp-hplc method and it’s validation for simultaneous estimation of sitagliptin and Metformin. International Journal of Pharmaceutical and Chemical Sciences 2012; 1: 360-364
- 12 Mohammad Abdul-Azim M, Ehab FE, Marwa AF. Development and validation of a reversed-phase column liquid chromatographic method for simultaneous determination of two novel gliptins in their binary mixtures with Metformin. Eur J Chem 2012; 3: 152-155
- 13 Thomas BA, Salamon B, Elfrides Eva SS et al. Stability-Indicating RP-LC Method for the Determination of Vildagliptin and Mass Spectrometry Detection for a Main Degradation Product. J Chromatogr Sci 2012; 50: 426-432
- 14 Pharne AB, Santhakumari B, Ghemud AS et al. Bio analytical method development and validation of vildagliptin a novel dipeptidyl peptidase iv inhibitor by RP-HPLC method. International Journal of Pharmacy and Pharmaceutical Science 2012; 4: 119-123
- 15 Mohammed Ishaq B, Vanitha Prakash K, Krishna Mohan G. RP-HPLC method for simultaneous estimation of metformin and vildagliptin in bulk and its tablet formulation. Journal of Global Trends in Pharmaceutical Sciences 2012; 3: 747-754
- 16 Nandipati S, Reddy VK, Reddy TR . Development and Validation of RP-HPLC method for Simultaneous Determination of Vildagliptin and Metformin in Bulk and Formulation Dosage. International Research Journal of Pharmaceutical Applied Science 2012; 2: 44-50
- 17 Santhosha B, Ravindranath A, Sundari Ch. Validated method for the simultaneous estimation of Metformin Hydrochloride and Vildagliptin by RP-HPLC in bulk and the pharmaceutical dosage form. International Research Journal of Pharmaceutical Applied Science 2012; 2–3: 22-28
- 18 Varma PSRChNP, Lakshmana Rao A, Dinda SC. Simultaneous estimation of metformin and vildagliptin in solid dosage form by Stability indicating RP-HPLC method. International Research Journal of Pharmacy 2013; 4: 122-128
- 19 ICH. International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use. Validation of Analytical Procedures: Text and Methodology Q2 (R1) 2005