Abstract
Study Design Case report and review of the literature.
Objective The objective of the article is to report the case of a 20-year-old patient with a threatened aortic injury from pedicle screw instrumentation successfully managed without aortic grafting.
Methods The patient's clinical course is retrospectively reviewed. The offending hardware was removed after gaining endovascular control of the aorta.
Results Intraoperative aortography was normal and no graft was placed. The patient remains asymptomatic at 2 years after surgery.
Conclusions Hardware impinging on the aorta can safely be removed by gaining endovascular control of the aorta. In the setting of normal intraoperative aortography in a young patient, we recommend against further intervention to avoid the known morbidity of aortic grafting.
-
References
- 1 Nathan H. Relations of the soft structures of the posterior mediastinum in the scoliotic spine. Acta Anat (Basel) 1988; 133 (3) 260-264
- 2 Papadoulas S, Konstantinou D, Kourea HP, Kritikos N, Haftouras N, Tsolakis JA. Vascular injury complicating lumbar disc surgery. A systematic review. Eur J Vasc Endovasc Surg 2002; 24 (3) 189-195
- 3 Hicks JM, Singla A, Shen FH, Arlet V. Complications of pedicle screw fixation in scoliosis surgery: a systematic review. Spine 2010; 35 (11) E465-E470
- 4 Kakkos SK, Shepard AD. Delayed presentation of aortic injury by pedicle screws: report of two cases and review of the literature. J Vasc Surg 2008; 47 (5) 1074-1082
- 5 Minor ME, Morrissey NJ, Peress R , et al. Endovascular treatment of an iatrogenic thoracic aortic injury after spinal instrumentation: case report. J Vasc Surg 2004; 39 (4) 893-896
- 6 Wegener B, Birkenmaier C, Fottner A, Jansson V, Dürr HR. Delayed perforation of the aorta by a thoracic pedicle screw. Eur Spine J 2008; 17 (Suppl. 02) S351-S354
- 7 Clarke MJ, Guzzo J, Wolinsky JP, Gokaslan Z, Black III JH. Combined endovascular and neurosurgical approach to the removal of an intraaortic pedicle screw. J Neurosurg Spine 2011; 15 (5) 550-554
- 8 Tschoeke SK, Gahr P, Krug L, Kasper AS, Heyde CE, Ertel W. Late diagnosis of pedicle screw malplacement with perforation of the thoracic aorta after posterior stabilization in a patient with multiple myeloma: case report. Spine 2011; 36 (13) E886-E890
- 9 Smythe WR, Carpenter JP. Upper abdominal aortic injury during spinal surgery. J Vasc Surg 1997; 25 (4) 774-777
- 10 Loh SA, Maldonaldo TS, Rockman CB , et al. Endovascular solutions to arterial injury due to posterior spine surgery. J Vasc Surg 2012; 55 (5) 1477-1481
- 11 Wood KB, Devine J, Fischer D, Dettori JR, Janssen M. Vascular injury in elective anterior lumbosacral surgery. Spine 2010; 35 (9, Suppl): S66-S75
- 12 Foxx KC, Kwak RC, Latzman JM, Samadani U. A retrospective analysis of pedicle screws in contact with the great vessels. J Neurosurg Spine 2010; 13 (3) 403-406
- 13 Faro FD, Farnsworth CL, Shapiro GS , et al. Thoracic vertebral screw impingement on the aorta in an in vivo bovine model. Spine 2005; 30 (21) 2406-2413
- 14 Quinney BE, Parmar GM, Nagre SB , et al. Long-term single institution comparison of endovascular aneurysm repair and open aortic aneurysm repair. J Vasc Surg 2011; 54 (6) 1592-1597 , discussion 1597–1598
- 15 van Keulen JW, de Vries JP, Dekker H , et al. One-year multicenter results of 100 abdominal aortic aneurysm patients treated with the Endurant stent graft. J Vasc Surg 2011; 54 (3) 609-615
-
Commentary References
- 1 Heary RF, Bono CM, Black M. Thoracic pedicle screws: postoperative computerized tomography scanning assessment. J Neurosurg 2004; 100 (4, Suppl Spine): 325-331
- 2 Stavridis SI, Bücking P, Schaeren S, Jeanneret B, Schnake KJ. Implant removal after posterior stabilization of the thoraco-lumbar spine. Arch Orthop Trauma Surg 2010; 130 (1) 119-123
- 3 Kakkos SK, Shepard AD. Delayed presentation of aortic injury by pedicle screws: report of two cases and review of the literature. J Vasc Surg 2008; 47 (5) 1074-1082
- 4 Faro FD, Farnsworth CL, Shapiro GS , et al. Thoracic vertebral screw impingement on the aorta in an in vivo bovine model. Spine (Phila Pa 1976) 2005; 30 (21) 2406-2413
- 5 Marone EM, Kahlberg A, Tshomba Y, Chiesa R. Single-center experience with endovascular treatment of acute blunt thoracic aortic injuries. J Cardiovasc Surg (Torino) 2013; 54 (1) 123-131