Endoscopy 2014; 46(S 01): E236-E237
DOI: 10.1055/s-0034-1365434
Cases and Techniques Library (CTL)
© Georg Thieme Verlag KG Stuttgart · New York

Recanalization using diathermic dilator for stent obstruction due to tumor ingrowth

Takeshi Ogura
Second Department of Internal Medicine, Osaka Medical College, Osaka, Japan
,
Daisuke Masuda
Second Department of Internal Medicine, Osaka Medical College, Osaka, Japan
,
Akira Imoto
Second Department of Internal Medicine, Osaka Medical College, Osaka, Japan
,
Rieko Kamiyama
Second Department of Internal Medicine, Osaka Medical College, Osaka, Japan
,
Saori Onda
Second Department of Internal Medicine, Osaka Medical College, Osaka, Japan
,
Kazuhide Higuchi
Second Department of Internal Medicine, Osaka Medical College, Osaka, Japan
› Author Affiliations
Further Information

Publication History

Publication Date:
07 May 2014 (online)

Endoscopic biliary drainage has become established as first-line treatment for obstructive jaundice. However, if the stent becomes obstructed by tumor ingrowth, re-intervention can sometimes be challenging. One of the challenges can be difficulty in dilating the stricture. Several techniques for resolving this have been reported, such as those using the Soehendra stent retriever or a needle-knife catheter [1] [2]. More recently, Kawakami et al. have reported on the clinical impact of transpapillary dilation of refractory severe biliary stricture and main pancreatic duct stricture using a diathermic dilator (Cysto-Gastro-Set; Endo-Flex GmbH, Voerde, Germany) ([Fig. 1]) [3] [4]. We report successful treatment for stent obstruction due to tumor ingrowth using this diathermic dilator.

Zoom Image
Fig. 1 The 6-Fr diathermic dilator (Cysto-Gastro-Set; Endo-Flex GmbH, Voerde, Germany) fit over the guidewire.

A 63-year-old man was admitted to our hospital because of obstructive jaundice. He had 8 months previously undergone placement of uncovered metallic stents (from the right to the common bile duct, and from the left to the lower bile duct) because of obstructive jaundice caused by bile duct cancer. We decided to perform a re-intervention. We inserted an endoscopic retrograde cholangiopancreatography (ERCP) cannula (MTW Endoskopie, Wesel, Germany) into the previously placed metallic stent, injected contrast medium, and visualized the stent obstruction ([Fig. 2]). We advanced a 0.025-inch guidewire (VisiGlide; Olympus Medical Systems, Tokyo, Japan) into the right intrahepatic bile duct, but could not then advance either the ERCP cannula or a balloon catheter past the obstruction ([Fig. 3]). Next, therefore, we advanced the diathermic dilator. Using an electrosurgical high-frequency generator (ESG-100; Olympus), diathermy was applied until the dilator passed through the stricture (in cut mode, 30 W in endo-cut mode) [3]. Finally, we placed a 6-Fr endoscopic nasal biliary drainage tube ([Fig. 4]). After 4 days, the patient underwent a second session, when a metallic stent was placed.

Zoom Image
Fig. 2 Cholangiography showed stent obstruction and a dilated biliary tree.
Zoom Image
Fig. 3 First, we inserted the guidewire and advanced first an endoscopic retrograde cholangiopancreatography cannula, then a balloon catheter, but severe stricture prevented further passage.
Zoom Image
Fig. 4 a, b After dilation of the stricture using the diathermic dilator, we successfully advanced a 6-Fr endoscopic nasal biliary drainage tube.


Quality:
We inserted an endoscopic retrograde cholangiopancreatography (ERCP) cannula and injected contrast medium. First, we advanced a 0.025-inch guidewire into the right intrahepatic bile duct, but we could not then advance either the ERCP cannula or a balloon catheter past the obstruction. Next, therefore, we advanced the diathermic dilator, and with this we successfully advanced into the right intrahepatic bile duct. Finally, we placed a 6-Fr endoscopic nasal biliary drainage tube.

The diathermic dilator is clinically useful and, to our knowledge, the case we have presented may be the first reported case of successful recanalization of stent obstruction using the diathermic dilator.

Endoscopy_UCTN_Code_TTT_1AR_2AF

 
  • References

  • 1 Faigel DO, Ginsberg GG, Kochman ML. Innovative use of the Soehendra stent retriever for biliary stricture recanalization. Gastrointest Endosc 1996; 44: 635
  • 2 Gao DJ, Hu B, Pan YM et al. Feasibility of using wire-guided needle knife electrocautery for refractory biliary and pancreatic strictures. Gastrointest Endosc 2013; 77: 752-758
  • 3 Kawakami H, Kuwatani M, Eto K et al. Resolution of a refractory severe biliary stricture using a diathermic sheath. Endoscopy 2012; 44: E119-120
  • 4 Kawakami H, Kuwatani M, Kawakubo K et al. Transpapillary dilation of refractory severe biliary stricture or main pancreatic duct by using a wire-guided diathermic dilator (with video). Gastrointest Endosc 2013; DOI: 10.1016/j.gie.2013.7.055.