Rofo 2014; 186(10): 959-961
DOI: 10.1055/s-0034-1366098
Technical Innovations
© Georg Thieme Verlag KG Stuttgart · New York

Contrast Enhancement Using Curd and Contrast Agent Mixtures for Ex Vivo Vessel Imaging in Computed Tomography

Kontrastanhebung mit einer Mischung aus Quark und Kontrastmittel für computertomografische ex vivo Gefäßdarstellungen
M. Obert
,
L. M. Kohl
,
N. Graf
,
G. A. Krombach
,
M. A. Verhoff
Further Information

Publication History

05 November 2013

13 January 2014

Publication Date:
19 March 2014 (online)

Abstract

We describe a cheap and efficient method for filling the vascular space of ex vivo tissue samples with a radiopaque material that can be used in computed tomography imaging. The filling material consists of curd, water, and a radiological contrast agent. Viscosity ranges and the degree of attenuation of X-rays of the filling material can be easily adjusted to the requirements of a specific application. The method is non-destructive and without negative effects on subsequent histological examinations.

Zusammenfassung

Wir beschreiben eine preisgünstige und effiziente Methode, um den Vaskular-Raum von ex vivo Gewebeproben mit einem röntgendichten Material auszufüllen, dass in der computertomografischen Bildgebung angewendet werden kann. Das Füllmaterial besteht aus Quark, Wasser und einem Röntgenkontrastmittel. Viskositätsbereiche und der Grad an Röntgenstrahlenabsorption des Füllmaterials lassen sich leicht an spezielle Anforderungen anpassen. Die Methode ist zerstörungsfrei und hat keine negativen Einflüsse auf nachfolgende histologische Untersuchungen.