RSS-Feed abonnieren
DOI: 10.1055/s-0034-1376973
A Maximal Cycle Test with Good Validity and High Repeatability in Adults of All Ages
Publikationsverlauf
accepted after revision 22. April 2014
Publikationsdatum:
26. September 2014 (online)
Abstract
In 11 680 individuals (18–85 years) maximal oxygen consumption (VO2max) was estimated indirectly in a maximal cycle test using a prediction model developed in a young population (15–28 years). A subsample of 182 individuals (23–77 years) underwent 2 maximal cycle tests with VO2max estimated indirectly in both tests and measured directly in one test. Agreement between the direct measurement and the indirect estimate of VO2max and repeatability of the indirect estimates of VO2max were examined by Bland-Altman plots, limits of agreement (LOA) and coefficient of repeatability (CR). The indirect method (mean VO2max=3 132 ml · min−1) underestimated VO2max as compared to the direct method (mean VO2max=3 190 ml · min−1) in men (bias: 58 ml · min−1 (95% LOA−450 and 565)) and overestimated VO2max in women (mean VO2max=2 328 vs. 2 258 ml · min−1, bias: − 70 ml · min−1 (95% LOA−468 and 328)). The mean difference between the 2 indirect estimates was non-significant (men: − 11.9 ml · min−1, women: 18.3 ml · min−1) with a CR of 279 ml · min−1 (8.9%) in men and 274 ml · min−1 (11.7%) in women. The validity of the indirect method was good despite minor sex-specific bias. Owing to this bias we suggest a new prediction model of VO2max. The maximal cycle test was highly repeatable.
-
References
- 1 American College of Sports Medicine . ACSM’s guidelines for exercise testing and prescription. Ninth edition Wolters Kluwer Health: Lippincott Williams & Wilkins; 2013: 72-75
- 2 American College of Sports Medicine . ACSM’s health-related physical fitness assessment manual. Third edition Wolters Kluwer Health: Lippincott Williams & Wilkins; 2010: 145
- 3 American College of Sports Medicine . ACSM’s guidelines for exercise testing and prescription. Seventh edition Lippincott Williams & Wilkins; 2006: 99-100
- 4 Andersen LB. A maximal cycle exercise protocol to predict maximal oxygen uptake. Scand J Med Sci Sports 1995; 5: 143-146
- 5 Åstrand I. Aerobic work capacity in men and women with special reference to age. Acta Physiol Scand 1960; 49: 83-84
- 6 Bingisser R, Kaplan V, Scherer T, Russi EW, Bloch KE. Effect of training on repeatability of cardiopulmonary exercise performance in normal men and women. Med Sci Sports Exerc 1997; 29: 1499-1504
- 7 Bland JM, Altman DG. Statistical Methods for assessing agreement between two methods of clinical measurement. The Lancet 1986; 1: 307-310
- 8 Borg G. Borg’s Perceived Exertion and Pain Scales. Champaign, IL: Human Kinetics; 1998: 29-39
- 9 Bruce RA, Blackmon JR, Jones JW, Strait G. Exercise testing in adult normal subjects and cardiac patients. Pediatrics 1963; 32: 742-756
- 10 Cooper KH. A means of assessing maximum oxygen uptake. JAMA 1968; 203: 201-204
- 11 Eriksen L, Grønbæk M, Helge JW, Tolstrup JS, Curtis T. The Danish Health Examination Survey 2007–2008 (DANHES 2007–2008). Scand J Pub Health 2011; 39: 203-211
- 12 Ettema G, Lorås HW. Efficiency in cycling: a review. Eur J Appl Physiol 2009; 106: 1-14
- 13 Harriss DJ, Atkinson G. Ethical standards in sport and exercise science research: 2014 update. Int J Sports Med 2013; 34: 1025-1028
- 14 Hawley JA, Noakes TD. Peak power output predicts maximal oxygen uptake and performance time in trained cyclists. Eur J Appl Physiol 1992; 65: 79-83
- 15 Hermansen L, Saltin B. Oxygen uptake during maximal treadmill and bicycle exercise. J Appl Physiol 1969; 26: 31-37
- 16 Kodama S, Saito K, Tanaka S, Maki M, Yachi Y, Asumi M, Sugawara A, Totsuka K, Shimano H, Ohashi Y, Yamada N, Sone H. Cardiorespiratory fitness as a quantitative predictor of all-cause mortality and cardiovascular events in healthy men and women: a meta-analysis. JAMA 2009; 301: 2024-2035
- 17 Krouwer JS. Why Bland-Altman plots should use X, not (Y+X)/2 when X is the reference method. Stat Med 2008; 27: 778-780
- 18 Kuipers H, Verstappen FT, Keizer HA, Geurten P, van Kranenburg G. Variability of aerobic performance in the laboratory and its physiologic correlates. Int J Sports Med 1985; 6: 197-201
- 19 Léger L, Gadoury C. Validity of the 20 m shuttle run test with 1 min stages to predict VO2max in adults. Can J Sport Sci 1989; 14: 21-26
- 20 Léger LA, Lambert J. A maximal multistage 20-m shuttle run test to predict VO2max. Eur J Appl Physiol 1982; 49: 1-12
- 21 Midgley AW, Bentley D, Luttikholt H, McNaughton LR, Millet GP. Challenging a dogma of exercise physiology: does an incremental exercise test for valid VO2max determination really need to last between 8 and 12 minutes?. Sports Med 2008; 38: 441-447
- 22 Midgley AW, Carroll S, Marchant D, McNaughton LR, Siegler J. Evaluation of true maximal oxygen uptake based on a novel set of standardized criteria. Appl Physiol Nutr Metab 2009; 34: 115-123
- 23 Myers J, Froelicher VF. Optimizing the exercise test for pharmacological investigations. Circulation 1990; 82: 1839-1846
- 24 Sacchetti M, Lenti M, Di Palumbo AS, De Vito G. Different effect of cadence on cycling efficiency between young and older cyclists. Med Sci Sports Exerc 2010; 42: 2128-2133
- 25 Storer TW, Davis JA, Caiozzo VJ. Accurate prediction of VO2max in cycle ergometry. Med Sci Sports Exerc 1990; 22: 704-712
- 26 Vercruyssen F, Brisswalter J. Which factors determine the freely chosen cadence during submaximal cycling. J Sci Med Sport 2010; 13: 225-231
- 27 Wergel-Kolmert U, Agehall A, Rosenberg N, Wohlfart B. Day-to-day variation in oxygen consumption at submaximal loads during ergometer cycling by adolescents. Clin Physiol 2001; 21: 135-140
- 28 Wergel-Kolmert U, Wisen A, Wohlfart B. Repeatability of measurements of oxygen consumption, heart rate and Borg’s scale in men during ergometer cycling. Clin Physiol Funct Imaging 2002; 22: 261-265
- 29 Wisén A, Wohlfart B. Exercise testing using a cycle or treadmill: a review of various protocols. Phys Ther Rev 1999; 4: 7-20