RSS-Feed abonnieren
DOI: 10.1055/s-0034-1378067
Interventioneller Vorhofohrverschluss bei Vorhofflimmer-Patienten mit hohem Blutungsrisiko
Publikationsverlauf
Publikationsdatum:
24. Oktober 2014 (online)
Abstract
Atrial fibrillation is the most common sustained cardiac arrhythmia worldwide. The left atrial appendage (LAA) is the main source of thrombi caused by atrial fibrillation because of decreased blood velocity. These thrombi can cause thrombembolic events in leaving the LAA into the systemic circulation. For preventing thromboembolic events a long-term oral anticoagulation therapy is recommended. The interventional LAA closure is a guideline appropriate therapy option for patients with non-valvular atrial fibrillation that cannot be treated with long-term oral anticoagulation. Thereby the LAA is sealed with an implant. This therapy has shown efficient prophylaxis of thrombembolic events with safe performance in several studies.
-
Der interventionelle Vorhofohrverschluss ist eine leitliniengerechte Therapiemöglichkeit bei Patienten mit nicht valvulärem Vorhofflimmern und Indikation zur oralen Antikoagulation, die nicht mit Langzeit-OAK behandelt werden können.
-
In Studien konnte gezeigt werden, dass der interventionelle Eingriff sicher durchführbar ist und einen effizienten Schutz gegen Thrombembolien bietet.
-
Aktuell gibt es mit dem Watchman-Device von Boston Scientific und dem Amplatzer Cardiac Plug von St. Jude Medical 2 LAA-Verschluss-Okkluder, die in Deutschland kommerziell erhältlich sind.
-
Klassische Komplikationen des interventionellen LAA-Verschlusses sind Perikarderguss/‑tamponade, Schlaganfall durch Luftembolie, Device-Verlust, Device-Thromben und Komplikationen an den Einstichstellen.
-
Eine präinterventionelle TEE zur Beurteilung der LAA-Anatomie mit Bestimmung von Eingangsdurchmesser und Tiefenausdehnung sowie der LAA-Konfiguration mit Bestimmung der Lobuli-Anzahl ist notwendig. Zum Zeitpunkt des Verschlusses darf kein LAA-Thrombus vorliegen.
-
Postinterventionell muss für 3 – 6 Monate eine Therapie mit Antikoagulanzien verschiedener Art durchgeführt werden, um eine Endothelialisierung des Devices zu ermöglichen. Hierzu gibt es aktuell noch kein abschließend empfehlenswertes Schema.
-
Literatur
- 1 Camm AJ, Lip GY, DE Caterina R et al. 2012 focused update of the ESC Guidelines for the management of atrial fibrillation: an update of the 2010 ESC guidelines for the management of atrial fibrillation. Developed with the special contribution of the European Heart Rhythm Association. Eur Heart J 2012; 33: 2719-2747
- 2 Connolly SJ, Ezekowitz MD, Yusuf S et al. Dabigatran versus warfarin in patients with atrial fibrillation. N Engl J Med 2009; 361: 1139-1151
- 3 Patel MR, Mahaffey KW, Garg J et al. Rivaroxaban versus warfarin in nonvalvular atrial fibrillation. N Engl J Med 2011; 365: 883-891
- 4 Connolly SJ, Eikelboom J, Joyner C et al. Apixaban in patients with atrial fibrillation. N Engl J Med 2011; 364: 806-817
- 5 Hart RG, Benavente O, McBride R et al. Antithrombotic therapy to prevent stroke in patients with atrial fibrillation: a meta-analysis. Ann Intern Med 1999; 131: 492-501
- 6 Friberg L, Rosenqvist M, Lip GY. Net clinical benefit of warfarin in patients with atrial fibrillation: a report from the Swedish atrial fibrillation cohort study. Circulation 2012; 125: 2298-2307
- 7 Nieuwlaat R, Capucci A, Camm AJ et al. Atrial fibrillation management: a prospective survey in ESC member countries: the Euro Heart Survey on Atrial Fibrillation. Eur Heart J 2005; 26: 2422-2434
- 8 Nucifora G, Faletra FF, Regoli F et al. Evaluation of the left atrial appendage with real-time 3-dimensional transesophageal echocardiography: implications for catheter-based left atrial appendage closure. Circ Cardiovasc Imaging 2011; 4: 514-523
- 9 Onalan O, Crystal E. Left atrial appendage exclusion for stroke prevention in patients with nonrheumatic atrial fibrillation. Stroke 2007; 38: 624-630
- 10 Cox JL, Palazzo T. Impact of the maze procedure on the stroke rate in patients with atrial fibrillation. J Thorac Cardiovasc Surg 1999; 118: 833-840
- 11 Bartus K, Han FT, Bednarek J et al. Percutaneous left atrial appendage suture ligation using the LARIAT device in patients with atrial fibrillation: initial clinical experience. J Am Coll Cardiol 2013; 62: 108-118
- 12 Stone D, Byrne T, Pershad A. Early Results With the LARIAT Device for Left Atrial Appendage Exclusion in Patients With Atrial Fibrillation at High Risk for Stroke and Anticoagulation. Catheter Cardiovasc Interv 2013;
- 13 Holmes DR, Reddy VY, Zoltan GT et al. Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: a randomised non-inferiority trial. Lancet 2009; 374: 534-542
- 14 Reddy V et al. Long Term Results of PROTECT AF: The Mortality Effects of Left Atrial Appendage Closure versus Warfarin for Stroke Prophylaxis in AF. Denver: Heart Rhythm Society; 2013 (vorgestellt am 9. Mai 2013)
- 15 Reddy V et al. Percutaneous left atrial appendage closure for stroke prophylaxis in patients with atrial fibrillation: 2.3-Year Follow-up of the PROTECT AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients with Atrial Fibrillation) Trial. Circulation 2013; 127: 720-729
- 16 Reddy V, Holmes D, Doshi SK et al. Safety of percutaneous left atrial appendage closure: results from the Watchman Left Atrial Appendage System for Embolic Protection in Patients with AF (PROTECT AF) clinical trial and the Continued Access Registry. Circulation 2011; 123: 417-424
- 17 Holmes DR et al. Prospective Randomized Evaluation of the Watchman Left Atrial Appendage Closure Device in Patients With Atrial Fibrillation Versus Long-Term Warfarin Therapy: The PREVAIL Trial. J Am Coll Cardiol 2014; 64: 1-12
- 18 Reddy V et al. LAA Closure Using the WATCHMAN™ Device in Patients with Contraindications to Warfarin: Preliminary Results from the “ASA Plavix Registry” (ASAP). HRS Congress: 2012 PO06-63
- 19 Park JW, Bethencourt A, Sievert H et al. Left atrial appendage closure with amplatzer cardiac plug in atrial fibrillation - Initial European experience. Catheter Cardiovasc Interv 2011; 77: 700-706
- 20 Nietlispach F, Gloekler S, Krause R et al. Amplatzer left atrial appendage occlusion: single center 10-year experience. Catheter Cardiovasc Interv 2013; 82: 283-289
- 21 Urena M, Rodés-Cabau J, Freixa X et al. Percutaneous Left Atrial Appendage Closure With the AMPLATZER Cardiac Plug Device in Patients With Nonvalvular Atrial Fibrillation and Contraindications to Anticoagulation Therapy. J Am Coll Cardiol 2013; 62: 96-102
- 22 Park JW et al. Results of the Amplatzer Cardiac Plug European Multicenter Observational Study. Paris: EuroPCI; 2012
- 23 Viles-Gonzalez JF, Kar S, Douglas P et al. The clinical impact of incomplete left atrial appendage closure with the Watchman Device in patients with atrial fibrillation: a PROTECT AF (Percutaneous Closure of the Left Atrial Appendage Versus Warfarin Therapy for Prevention of Stroke in Patients With Atrial Fibrillation) substudy. J Am Coll Cardiol 2012; 59: 923-929
- 24 Meincke F. Dabigatran for anticoagulation following left atrial appendage closure: the ALSTER LAA registry. EuroPCR; 2013
- 25 Price MJ, Gibson DN, Yakubov SJ et al. Early Safety and Efficacy of Percutaneous Left Atrial Appendage Suture Ligation. Results From the U. S. Transcatheter LAA Ligation Consortium. J Am Coll Cardiol 2014; 64: 565-572
- 26 Dagres ND, Rolf S, Hindricks G. Percutaneous Left Atrial Appendage Suture Ligation. Not Ready for Prime Time. J Am Coll Cardiol 2014; 64: 573-575