Duodenal diverticular bleeding has traditionally required invasive surgical repair. With improvements in endoscopic devices, endoscopic treatment has become the main therapy for such bleeding [1] [2]. However, the question of which endoscopic devices should be used is still controversial because of complications and recurrent bleeding after treatment [3]. A newly developed device, the over-the-scope clip (OTSC) [4], has been reported to be useful for treatment of bleeding gastrointestinal lesions that are resistant to conventional therapy [5]. Here we report the first case of complete hemostasis using an OTSC system and a colonoscope for bleeding from a Dieulafoy lesion that was located in a duodenal diverticulum and was resistant to conventional therapy.
An 81-year-old man presented with tarry stool and severe anemia. Upper gastrointestinal endoscopy failed to detect the bleeding site. Re-bleeding occurred during a capsule endoscopy. Informed consent was obtained from the patient before the following treatment was undertaken.
Because fresh blood had been found from the deep second portion of the duodenum toward the anal side, a colonoscope with a waterjet function (PCF-Q260AI; Olympus, Tokyo, Japan) was introduced. This contributed to clear identification of a Dieulafoy lesion at the edge of a large diverticulum in the third portion of the duodenum. Endoscopic hemostasis using hemostatic forceps (Coagrasper, FD-411UR; Olympus) only diminished the blood flow from spurting ([Fig. 1]) to oozing. Because of the risk of perforation when using coagulation in the thin duodenal wall, an OTSC system (Ovesco Endoscopy, Tübingen, Germany) was selected as the next step. The entire defect of the bleeding ulcer was successfully closed using the OTSC as shown in the schema ([Fig. 2 a – c]), resulting in complete hemostasis ([Fig. 3], [Video 1]).
Qualität:
Computed tomography (CT) 7 days later showed successful placement of an OTSC in the duodenal diverticulum ([Fig. 4]). Our patient had an excellent outcome with no recurrence of bleeding or associated complications over the 6-month follow-up period. This case demonstrates that OTSC deployment is an effective and secure treatment option for the management of duodenal diverticular bleeding.
Endoscopy_UCTN_Code_TTT_1AO_2AD
-
References
- 1 Kachi M, Fujii M, Tateiwa S et al. Endoscopic injection therapy for the treatment of duodenal diverticulum bleeding. J Gastroenterol Hepatol 2002; 17: 1241-1242
- 2 Moyer MT, Bethards DM. Identification and treatment of a duodenal diverticular hemorrhage: an illustration of the usefulness of the jumbo-channel therapeutic endoscope. Endoscopy 2009; 41: E230-E231
- 3 Chen YY, Yen HH, Soon MS. Impact of endoscopy in the management of duodenal diverticular bleeding: experience of a single medical center and a review of recent literature. Gastrointest Endosc 2007; 66: 831-835
- 4 Kirschniak A, Kratt T, Königsrainer A et al. A new endoscopic over-the-scope clip system for treatment of lesions and bleeding in the GI tract: first clinical experiences. Gastrointest Endosc 2007; 66: 162-167
- 5 Nishiyama N, Mori H, Kobara H et al. Efficacy and safety of over-the-scope clip: including complications after endoscopic submucosal dissection. World J Gastroenterol 2013; 19: 2752-2760