RSS-Feed abonnieren
DOI: 10.1055/s-0034-1398680
The Reliability of Running Performance in a 5 km Time Trial on a Non-motorized Treadmill
Publikationsverlauf
accepted after revision 12. Januar 2015
Publikationsdatum:
19. März 2015 (online)
Abstract
The purpose of the study was to establish the reliability of performance and physiological responses during a self-paced 5 km running time trial on a non-motorized treadmill. 17 male runners (age: 32±13 years, height: 177±7 cm, body mass: 71±9 kg, sum of 7 skinfolds: 55±21 mm) performed familiarization then 2 separate maximal 5 km running time trials on a non-motorized treadmill. Physiological responses measured included heart rate, oxygen uptake, expired air volume, blood lactate concentration, tissue saturation index and integrated electromyography. Running time (1 522±163 s vs. 1 519±162 s for trials 1 and 2, respectively) demonstrated a low CV of 1.2% and high ICC of 0.99. All physiological variables had CVs of less than 4% and ICCs of >0.92, with the exception of blood lactate concentration (7.0±2 mmol·L−1 vs. 6.5±1.5 mmol·L−1 for trials 1 and 2, respectively; CV: 12%, ICC: 0.83) and the electromyography measures (CV: 8–27%, ICC: 0.71–0.91). The data demonstrate that performance time in a 5 km running time trial on a non-motorized treadmill is a highly reliable test. Most physiological responses measured across the 5 km run also demonstrated good reliability.
-
References
- 1 Aldous JW, Akubat I, Chrismas BC, Watkins SL, Mauger AR, Midgley AW, Abt G, Taylor L. The reliability and validity of a soccer specific non-motorized treadmill simulation (iSPT). J Strength Cond Res 2013; 28: 1971-1980
- 2 Atkinson G, Nevill AM. Selected issues in the design and analysis of sport performance research. J Sports Sci 2001; 19: 811-827
- 3 Austin KG, Daigle KA, Patterson P, Cowman J, Chelland S, Haymes EM. Reliability of near-infrared spectroscopy for determining muscle oxygen saturation during exercise. Res Q Exerc Sport 2005; 76: 440-449
- 4 Billaut F, Davis JM, Smith KJ, Marino FE, Noakes TD. Cerebral oxygenation decreases but does not impair performance during self-paced, strenuous exercise. Acta Physiol (Oxf) 2010; 198: 477-486
- 5 Borg GA. Psychophysical bases of perceived exertion. Med Sci Sports Exerc 1982; 14: 377-381
- 6 Buchheit M, Laursen PB, Ahmaidi S. Effect of prior exercise on pulmonary O2 uptake and estimated muscle capillary blood flow kinetics during moderate-intensity field running in men. J Appl Physiol 2009; 107: 460-470
- 7 Buchheit M, Ufland P, Haydar B, Laursen PB, Ahmaidi S. Reproducibility and sensitivity of muscle reoxygenation and oxygen uptake recovery kinetics following running exercise in the field. Clin Physiol Funct Imaging 2011; 31: 337-346
- 8 Corbett J, Barwood MJ, Ouzounoglou A, Thelwell R, Dicks M. Influence of competition on performance and pacing during cycling exercise. Med Sci Sports Exerc 2012; 44: 509-515
- 9 Doyle JA, Martinez AL. Reliability of a protocol for testing endurance performance in runners and cyclists. Res Q Exerc Sport 1998; 69: 304-307
- 10 Harriss DJ, Atkinson G. Ethical standards in sport and exercise science research: 2014 update. Int J Sports Med 2013; 34: 1025-1028
- 11 Hermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol 2000; 10: 361-374
- 12 Hopkins WG. Measures of reliability in sports medicine and science. Sports Med 2000; 30: 1-15
- 13 Hurst P, Board L. Reproducibility of outdoor 5 km running time-trial in a competitive environment. Br J Sports Med 2013; 47: e4
- 14 Jeukendrup A, Saris WH, Brouns F, Kester AD. A new validated endurance performance test. Med Sci Sports Exerc 1996; 28: 266-270
- 15 Laursen PB, Francis GT, Abbiss CR, Newton MJ, Nosaka K. Reliability of time-to-exhaustion versus time-trial running tests in runners. Med Sci Sports Exerc 2007; 39: 1374-1379
- 16 McCarron J, Hodgson T, Smith M. Brain drain: evaluating the impact of increased cognitive load during self-paced running performance. Br J Sports Med 2013; 47: e4
- 17 Russell RD, Redmann SM, Ravussin E, Hunter GR, Larson-Meyer DE. Reproducibility of endurance performance on a treadmill using a preloaded time trial. Med Sci Sports Exerc 2004; 36: 717-724
- 18 Schabort EJ, Hawley JA, Hopkins WG, Mujika I, Noakes TD. A new reliable laboratory test of endurance performance for road cyclists. Med Sci Sports Exerc 1998; 30: 1744-1750
- 19 Sirotic AC, Coutts AJ. The reliability of physiological and performance measures during simulated team-sport running on a non-motorized treadmill. J Sci Med Sport 2008; 11: 500-509
- 20 Smith MF, Davison RC, Balmer J, Bird SR. Reliability of mean power recorded during indoor and outdoor self-paced 40 km cycling time-trials. Int J Sports Med 2001; 22: 270-274
- 21 Smoliga JM, Myers JB, Redfern MS, Lephart SM. Reliability and precision of EMG in leg, torso, and arm muscles during running. J Electromyogr Kinesiol 2010; 20: e1-e9
- 22 Sporer BC, McKenzie DC. Reproducibility of a laboratory based 20-km time trial evaluation in competitive cyclists using the Velotron Pro ergometer. Int J Sports Med 2007; 28: 940-944
- 23 Tyler C, Sunderland C. The effect of ambient temperature on the reliability of a preloaded treadmill time-trial. Int J Sports Med 2008; 29: 812-816
- 24 van Beekvelt MC, van Engelen BG, Wevers RA, Colier WN. In vivo quantitative near-infrared spectroscopy in skeletal muscle during incremental isometric handgrip exercise. Clin Physiol Funct Imaging 2002; 22: 210-217
- 25 Young AJ, Sawka MN, Epstein Y, Decristofano B, Pandolf KB. Cooling different body surfaces during upper and lower body exercise. J Appl Physiol 1987; 63: 1218-1223
- 26 Zavorsky GS, Murias JM, Gow J, Kim DJ, Poulin-Harnois C, Kubow S, Lands LC. Laboratory 20-km cycle time trial reproducibility. Int J Sports Med 2007; 28: 743-748