Abstract
The failed total knee arthroplasty is a challenge to the surgeon and the patient. Infection, bone loss, and instability lead to a chronically painful and dysfunctional limb. Two-stage revision arthroplasty has been successful in clearing a majority of periprosthetic joint infections. However, there are many cases when the multiply revised and infected total knee arthroplasty cannot be salvaged. We report, a review of knee arthrodesis and a novel technique to manage significant bone loss. The use of trabecular metal cones and a long intramedullary nail can be used in concert with an autologous intramedullary bone graft to provide a stable, length restoring construct with sufficient biology to heal very large bone voids. With this technique we have successfully restored function and stability in the failed knee arthroplasty.
-
References
- 1 Nelson CL, Evarts CM. Arthroplasty and arthrodesis of the knee joint. Orthop Clin North Am 1971; 2 (1) 245-264
- 2 Charnley J, Lowe HG. A study of the end-results of compression arthrodesis of the knee. J Bone Joint Surg Br 1958; 40-B (4) 633-635
- 3 Bargiotas K, Wohlrab D, Sewecke JJ, Lavinge G, Demeo PJ, Sotereanos NG. Arthrodesis of the knee with a long intramedullary nail following the failure of a total knee arthroplasty as the result of infection. J Bone Joint Surg Am 2006; 88 (3) 553-558
- 4 Arroyo JS, Garvin KL, Neff JR. Arthrodesis of the knee with a modular titanium intramedullary nail. J Bone Joint Surg Am 1997; 79 (1) 26-35
- 5 Brooker Jr AF, Hansen Jr NM. The biplane frame: modified compression arthrodesis of the knee. Clin Orthop Relat Res 1981; (160) 163-167
- 6 Kuo AC, Meehan JP, Lee M. Knee fusion using dual platings with the locking compression plate. J Arthroplasty 2005; 20 (6) 772-776
- 7 Rasmussen MR, Bishop AT, Wood MB. Arthrodesis of the knee with a vascularized fibular rotatory graft. J Bone Joint Surg Am 1995; 77 (5) 751-759
- 8 Oostenbroek HJ, van Roermund PM. Arthrodesis of the knee after an infected arthroplasty using the Ilizarov method. J Bone Joint Surg Br 2001; 83 (1) 50-54
- 9 Lai KA, Shen WJ, Yang CY. Arthrodesis with a short Huckstep nail as a salvage procedure for failed total knee arthroplasty. J Bone Joint Surg Am 1998; 80 (3) 380-388
- 10 White SP, Porteous AJ, Newman JH, Mintowt-Czyz W, Barr V. Arthrodesis of the knee using a custom-made intramedullary coupled device. J Bone Joint Surg Br 2003; 85 (1) 57-61
- 11 Leopold SS, Greidanus N, Paprosky WG, Berger RA, Rosenberg AG. High rate of failure of allograft reconstruction of the extensor mechanism after total knee arthroplasty. J Bone Joint Surg Am 1999; 81 (11) 1574-1579
- 12 Watanabe K, Minowa T, Takeda S , et al. Outcomes of knee arthrodesis following infected total knee arthroplasty: a retrospective analysis of 8 cases. Mod Rheumatol 2014; 24 (2) 243-249
- 13 Attias N, Lindsey RW. Case reports: management of large segmental tibial defects using a cylindrical mesh cage. Clin Orthop Relat Res 2006; 450 (450) 259-266
- 14 Lawal YZ, Garba ES, Ogirima MO , et al. Use of non-vascularized autologous fibula strut graft in the treatment of segmental bone loss. Ann Afr Med 2011; 10 (1) 25-28
- 15 Rozbruch SR, Ilizarov S, Blyakher A. Knee arthrodesis with simultaneous lengthening using the Ilizarov method. J Orthop Trauma 2005; 19 (3) 171-179
- 16 Stannard JP, Sathy AK, Moeinpour F, Stewart RL, Volgas DA. Quantitative analysis of growth factors from a second filter using the Reamer-Irrigator-Aspirator system: description of a novel technique. Orthop Clin North Am 2010; 41 (1) 95-98
- 17 Uppal HS, Peterson BE, Misfeldt ML , et al. The viability of cells obtained using the Reamer-Irrigator-Aspirator system and in bone graft from the iliac crest. Bone Joint J 2013; 95-B (9) 1269-1274
- 18 Whatling GM, Nokes LD. Literature review of current techniques for the insertion of distal screws into intramedullary locking nails. Injury 2006; 37 (2) 109-119
- 19 Mensch G, Ellis PE. Running patterns of transfemoral amputees: a clinical analysis. Prosthet Orthot Int 1986; 10 (3) 129-134
- 20 Friberg O. Leg length asymmetry in stress fractures. A clinical and radiological study. J Sports Med Phys Fitness 1982; 22 (4) 485-488
- 21 Giles LG, Taylor JR. Low-back pain associated with leg length inequality. Spine 1981; 6 (5) 510-521