Subscribe to RSS
DOI: 10.1055/s-0037-1606368
The Hemodynamics of Labor in Women Undergoing Vaginal and Cesarean Deliveries as Determined by Whole Body Bioimpedance
Publication History
05 April 2017
07 August 2017
Publication Date:
30 August 2017 (online)
Abstract
Objective The objective of this study was to assess the hemodynamics of labor, delivery, and 48 hours postpartum in women undergoing vaginal and cesarean deliveries by utilizing a whole body bioimpedance-based device.
Materials and Methods A prospective longitudinal single-center observational study was performed between September 2014 and September 2015. The hemodynamics of low-risk women undergoing spontaneous vaginal delivery were compared with those undergoing elective cesarean sections. Cardiac index (CI), stroke index, total peripheral resistance index (TPRI), and mean arterial pressure (MAP) were assessed at different time points during delivery and in the immediate postpartum period (1, 24, and 48 hours postpartum).
Results Eighty-seven women were evaluated, 63 parturients in the vaginal delivery group and 24 in the cesarean delivery group. Normal vaginal delivery was characterized by a reduction in MAP and CI after epidural anesthesia, whereas elective cesarean sections were characterized by a rise in MAP and CI after spinal anesthesia. As labor progressed, CI increased reaching its peak during the second stage. Immediately following delivery, TPRI declined to its nadir with no significant change in CI. As opposed to vaginal delivery, in cesarean delivery, TPRI peaked within 1-hour postpartum resulting in a significant decline in CI.
Conclusion Whole body bioimpedance can be used effectively to assess the hemodynamics of vaginal and cesarean deliveries.
Funding
None.
-
References
- 1 Lockitch G. Clinical biochemistry of pregnancy. Crit Rev Clin Lab Sci 1997; 34 (01) 67-139
- 2 Hunter S, Robson SC. Adaptation of the maternal heart in pregnancy. Br Heart J 1992; 68 (06) 540-543
- 3 Mashini IS, Albazzaz SJ, Fadel HE. , et al. Serial noninvasive evaluation of cardiovascular hemodynamics during pregnancy. Am J Obstet Gynecol 1987; 156 (05) 1208-1213
- 4 Ouzounian JG, Elkayam U. Physiologic changes during normal pregnancy and delivery. Cardiol Clin 2012; 30 (03) 317-329
- 5 Maruta S. [The observation of the maternal hemodynamics during labor and cesarean section (author's transl)]. Nippon Sanka Fujinka Gakkai Zasshi 1982; 34 (06) 776-784
- 6 Klein HH, Pich S. Cardiovascular changes during pregnancy [in German]. Herz 2003; 28 (03) 173-174
- 7 Lee W, Rokey R, Miller J, Cotton DB. Maternal hemodynamic effects of uterine contractions by M-mode and pulsed-Doppler echocardiography. Am J Obstet Gynecol 1989; 161 (04) 974-977
- 8 Langesæter E, Dyer RA. Maternal haemodynamic changes during spinal anaesthesia for caesarean section. Curr Opin Anaesthesiol 2011; 24 (03) 242-248
- 9 Danilenko-Dixon DR, Tefft L, Cohen RA, Haydon B, Carpenter MW. Positional effects on maternal cardiac output during labor with epidural analgesia. Am J Obstet Gynecol 1996; 175 (4 Pt 1): 867-872
- 10 van Oppen AC, Stigter RH, Bruinse HW. Cardiac output in normal pregnancy: a critical review. Obstet Gynecol 1996; 87 (02) 310-318
- 11 Morris EA, Hale SA, Badger GJ, Magness RR, Bernstein IM. Pregnancy induces persistent changes in vascular compliance in primiparous women. Am J Obstet Gynecol 2015; 212 (05) 633.e1-633.e6
- 12 Mahendru AA, Everett TR, Wilkinson IB, Lees CC, McEniery CM. A longitudinal study of maternal cardiovascular function from preconception to the postpartum period. J Hypertens 2014; 32 (04) 849-856
- 13 Easterling TR, Carlson KL, Schmucker BC, Brateng DA, Benedetti TJ. Measurement of cardiac output in pregnancy by Doppler technique. Am J Perinatol 1990; 7 (03) 220-222
- 14 Belfort MA, Rokey R, Saade GR, Moise Jr KJ. Rapid echocardiographic assessment of left and right heart hemodynamics in critically ill obstetric patients. Am J Obstet Gynecol 1994; 171 (04) 884-892
- 15 Milsom I, Forssman L, Sivertsson R, Dottori O. Measurement of cardiac stroke volume by impedance cardiography in the last trimester of pregnancy. Acta Obstet Gynecol Scand 1983; 62 (05) 473-479
- 16 Turner MA. Doppler-based hemodynamic monitoring: a minimally invasive alternative. AACN Clin Issues 2003; 14 (02) 220-231
- 17 Fayers S, Moodley J, Naidoo DP. Cardiovascular haemodynamics in pre-eclampsia using brain naturetic peptide and tissue Doppler studies. Cardiovasc J Afr 2013; 24 (04) 130-136
- 18 Rosseland LA, Hauge TH, Grindheim G, Stubhaug A, Langesæter E. Changes in blood pressure and cardiac output during cesarean delivery: the effects of oxytocin and carbetocin compared with placebo. Anesthesiology 2013; 119 (03) 541-551
- 19 San-Frutos L, Engels V, Zapardiel I. , et al. Hemodynamic changes during pregnancy and postpartum: a prospective study using thoracicelectrical bioimpedance. J Matern Fetal Neonatal Med 2011; 24 (11) 1333-1340
- 20 Volman MN, Rep A, Kadzinska I. , et al. Haemodynamic changes in the second half of pregnancy: a longitudinal, noninvasive study with thoracic electrical bioimpedance. BJOG 2007; 114 (05) 576-581
- 21 Handelsman H. Public health service reassessment: measuring cardiac output by electrical bioimpedance. Health Technology Assessment Reports, US Dept Health and Human Services. Public Agency for Health Care Policy and Research 1991; 6: 1-13
- 22 Raaijmakers E, Faes TJ, Scholten RJ, Goovaerts HG, Heethaar RM. A meta-analysis of published studies concerning the validity of thoracic impedance cardiography. Ann N Y Acad Sci 1999; 873: 121-127
- 23 Moshkovitz Y, Kaluski E, Milo O, Vered Z, Cotter G. Recent developments in cardiac output determination by bioimpedance: comparison with invasive cardiac output and potential cardiovascular applications. Curr Opin Cardiol 2004; 19 (03) 229-237
- 24 Cotter G, Moshkovitz Y, Kaluski E. , et al. Accurate, noninvasive continuous monitoring of cardiac output by whole-body electrical bioimpedance. Chest 2004; 125 (04) 1431-1440
- 25 Paredes OL, Shite J, Shinke T. , et al. Impedance cardiography for cardiac output estimation: reliability of wrist-to-ankle electrode configuration. Circ J 2006; 70 (09) 1164-1168
- 26 Taniguchi Y, Emoto N, Miyagawa K. , et al. Noninvasive and simple assessment of cardiac output and pulmonary vascular resistance with whole-body impedance cardiography is useful for monitoring patients with pulmonary hypertension. Circ J 2013; 77 (09) 2383-2389
- 27 Ram M, Lavie A, Lev S. , et al. Cardiac hemodynamics before, during and after elective cesarean section under spinal anesthesia in low-risk women. J Perinatol 2017
- 28 Dollberg S, Haklai Z, Mimouni FB, Gorfein I, Gordon ES. Birth weight standards in the live-born population in Israel. Isr Med Assoc J 2005; 7 (05) 311-314
- 29 McIntyre JP, Ellyett KM, Mitchell EA. , et al; Maternal Sleep in Pregnancy Study Group. Validation of thoracic impedance cardiography by echocardiography in healthy late pregnancy. BMC Pregnancy Childbirth 2015; 15 (15) 70-79
- 30 Ueland K, Hansen JM. Maternal cardiovascular dynamics. II. Posture and uterine contractions. Am J Obstet Gynecol 1969; 103 (01) 1-7
- 31 Adams JQ, Alexander Jr AM. Alterations in cardiovascular physiology during labor. Obstet Gynecol 1958; 12 (05) 542-549
- 32 Mulic-Lutvica A, Eurenius K, Axelsson O. Longitudinal study of Doppler flow resistance indices of the uterine arteries after normal vaginal delivery. Acta Obstet Gynecol Scand 2007; 86 (10) 1207-1214