Subscribe to RSS
DOI: 10.1055/s-0037-1607196
Preliminary Experience with a Novel System of Facet Fixation to Treat Patients with Lumbar Degenerative Disease. A New Perspective in Minimally Invasive Spine Surgery?
Publication History
21 February 2017
17 July 2017
Publication Date:
17 October 2017 (online)
Abstract
Purpose We report our experience with a novel surgical device for the treatment of lumbar degenerative microinstability. Facet Wedge (DePuy Synthes, Raynham, Massachusetts, United States) is a novel technique of intra-articular lumbar facet fixation that provides a minimally invasive alternative to standard posterior fixation.
Materials and Methods From November 2014 to July 2015, 38 patients underwent single-level Facet Wedge implantation. The main surgical indications included herniated disk (18 patients), spinal canal and foraminal stenosis (14 patients), and Meyerding grade I degenerative spondylolisthesis (6 patients). All the patients showed radiologic signs of microinstability: hyperintensity in both facet joints (facet fluid signal) in T2-weighted magnetic resonance imaging and a black disk as a sign of degenerative disease. No slippage was evident at dynamic radiograph. After a period of conservative treatment (minimum of 6 months), surgery was performed. All patients' follow-up lasted over at least 12 months.
Results The low back visual analog scale score decreased significantly after surgery (from an average of 8.2 to 3.1 at final follow-up). Postoperatively, the Oswestry Disability Index showed a significant reduction (14.7 on average). No slippage or signs of adjacent segment degeneration was detected in neuroimaging follow-up.
Conclusion Facet Wedge allows facet fixation in lumbar degenerative microinstability. To the best of our knowledge, this is the first clinical series reported in the literature on this novel device.
-
References
- 1 Goel A, Shah A, Jadhav M, Nama S. Distraction of facets with intraarticular spacers as treatment for lumbar canal stenosis: report on a preliminary experience with 21 cases. J Neurosurg Spine 2013; 19 (06) 672-677
- 2 Caterini R, Mancini F, Bisicchia S, Maglione P, Farsetti P. The correlation between exaggerated fluid in lumbar facet joints and degenerative spondylolisthesis: prospective study of 52 patients. J Orthop Traumatol 2011; 12 (02) 87-91
- 3 Landi A, Gregori F, Mancarella C. , et al. Lumbar spinal degenerative “microinstability”: hype or hope? Proposal of a new classification to detect it and to assess surgical treatment. Eur Spine J 2015; 24 (Suppl. 07) 872-878
- 4 King D. Internal fixation for lumbosacral fusion. Am J Surg 1944; 66: 357-361
- 5 Boucher HH. A method of spinal fusion. J Bone Joint Surg 1959; 41B: 248-259
- 6 Hartensuer R, Riesenbeck O, Schulze M. , et al. Biomechanical evaluation of the Facet Wedge: a refined technique for facet fixation. Eur Spine J 2014; 23 (11) 2321-2329
- 7 Goel A, Goel AA, Satoskar SR, Mehta PH. Double insurance transfacetal screws for lumbar spinal stabilization. J Craniovertebr Junction Spine 2014; 5 (02) 85-87
- 8 Graziano F, Maugeri R, Basile L, Meccio F, Iacopino DG. Autologous fibrin sealant (Vivostat(®)) in the neurosurgical practice: Part II: Vertebro-spinal procedures. Surg Neurol Int 2016; 7 (Suppl. 03) S77-S82
- 9 Graziano F, Certo F, Basile L. , et al. Autologous fibrin sealant (Vivostat(®)) in the neurosurgical practice: Part I: Intracranial surgical procedure. Surg Neurol Int 2015; 6: 77
- 10 Maugeri R, Basile L, Giugno A, Graziano F, Iacopino DG. Impasse in the management of recurrent basal cell carcinoma of the skull with sagittal sinus erosion. Interdiscip Neurosurg 2015; 2 (03) 160-163
- 11 Maugeri R, Giammalva GR, Graziano F, Iacopino DG. May autologue fibrin glue alone enhance ossification? An unexpected spinal fusion. World Neurosurg 2016; 95: 611-612
- 12 Hipp JA, Guyer RD, Zigler JE, Ohnmeiss DD, Wharton ND. Development of a novel radiographic measure of lumbar instability and validation using the facet fluid sign. Int J Spine Surg 2015; 9: 37
- 13 White III AA, Panjabi MM. The basic kinematics of the human spine. A review of past and current knowledge. Spine 1978; 3 (01) 12-20
- 14 Schinnerer KA, Katz LD, Grauer JN. MR findings of exaggerated fluid in facet joints predicts instability. J Spinal Disord Tech 2008; 21 (07) 468-472
- 15 Lattig F, Fekete TF, Kleinstück FS, Porchet F, Jeszenszky D, Mannion AF. Lumbar facet joint effusion on MRI as a sign of unstable degenerative spondylolisthesis: should it influence the treatment decision?. J Spinal Disord Tech 2015; 28 (03) 95-100
- 16 Lattig F, Fekete TF, Grob D, Kleinstück FS, Jeszenszky D, Mannion AF. Lumbar facet joint effusion in MRI: a sign of instability in degenerative spondylolisthesis?. Eur Spine J 2012; 21 (02) 276-281
- 17 Chaput C, Padon D, Rush J, Lenehan E, Rahm M. The significance of increased fluid signal on magnetic resonance imaging in lumbar facets in relationship to degenerative spondylolisthesis. Spine 2007; 32 (17) 1883-1887
- 18 Bendo JA, Ong B. Importance of correlating static and dynamic imaging studies in diagnosing degenerative lumbar spondylolisthesis. Am J Orthop 2001; 30 (03) 247-250
- 19 Lee SE, Jahng TA, Kim HJ. Facet joint changes after application of lumbar nonfusion dynamic stabilization. Neurosurg Focus 2016; 40 (01) E6
- 20 Rihn JA, Lee JY, Khan M. , et al. Does lumbar facet fluid detected on magnetic resonance imaging correlate with radiographic instability in patients with degenerative lumbar disease?. Spine 2007; 32 (14) 1555-1560
- 21 Cho BY, Murovic JA, Park J. Imaging correlation of the degree of degenerative L4-5 spondylolisthesis with the corresponding amount of facet fluid. J Neurosurg Spine 2009; 11 (05) 614-619
- 22 Hasegawa K, Kitahara K, Shimoda H, Hara T. Facet joint opening in lumbar degenerative diseases indicating segmental instability. J Neurosurg Spine 2010; 12 (06) 687-693
- 23 Snoddy MC, Sielatycki JA, Sivaganesan A, Engstrom SM, McGirt MJ, Devin CJ. Can facet joint fluid on MRI and dynamic instability be a predictor of improvement in back pain following lumbar fusion for degenerative spondylolisthesis?. Eur Spine J 2016; 25 (08) 2408-2415
- 24 Fujiwara A, Tamai K, Yamato M. , et al. The relationship between facet joint osteoarthritis and disc degeneration of the lumbar spine: an MRI study. Eur Spine J 1999; 8 (05) 396-401
- 25 Mori K, Nishizawa K, Nakamura A, Imai S. Short-term clinical result of cortical bone trajectory technique for the treatment of degenerative lumbar spondylolisthesis with more than 1-year follow-up. Asian Spine J 2016; 10 (02) 238-244
- 26 Snyder LA, Martinez-Del-Campo E, Neal MT. , et al. Lumbar spinal fixation with cortical bone trajectory pedicle screws in 79 patients with degenerative disease: perioperative outcomes and complications. World Neurosurg 2016; 88: 205-213
- 27 Glennie RA, Dea N, Kwon BK, Street JT. Early clinical results with cortically based pedicle screw trajectory for fusion of the degenerative lumbar spine. J Clin Neurosci 2015; 22 (06) 972-975
- 28 Fabrizi AP, Maina R, Schiabello L. Interspinous spacers in the treatment of degenerative lumbar spinal disease: our experience with DIAM and Aperius devices. Eur Spine J 2011; 20 (Suppl. 01) S20-S26
- 29 Surace MF, Fagetti A, Fozzato S, Cherubino P. Lumbar spinal stenosis treatment with Aperius perclid interspinous system. Eur Spine J 2012; 21 (Suppl. 01) S69-S74
- 30 Buric J, Pulidori M. Long-term reduction in pain and disability after surgery with the interspinous device for intervertebral assisted motion (DIAM) spinal stabilization system in patients with low back pain: 4-year follow-up from a longitudinal prospective case series. Eur Spine J 2011; 20 (08) 1304-1311
- 31 Jutte PC, Castelein RM. Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations. Eur Spine J 2002; 11 (06) 594-598
- 32 Gautschi OP, Schatlo B, Schaller K, Tessitore E. Clinically relevant complications related to pedicle screw placement in thoracolumbar surgery and their management: a literature review of 35,630 pedicle screws. Neurosurg Focus 2011; 31 (04) E8
- 33 Babu R, Park JG, Mehta AI. , et al. Comparison of superior-level facet joint violations during open and percutaneous pedicle screw placement. Neurosurgery 2012; 71 (05) 962-970
- 34 Wang L, Wang Y, Yu B, Li Z, Li Y. Comparison of cranial facet joint violation rate between percutaneous and open pedicle screw placement: a systematic review and meta-analysis. Medicine (Baltimore) 2015; 94 (05) e504
- 35 Verhoof OJ, Bron JL, Wapstra FH, van Royen BJ. High failure rate of the interspinous distraction device (X-Stop) for the treatment of lumbar spinal stenosis caused by degenerative spondylolisthesis. Eur Spine J 2008; 17 (02) 188-192
- 36 Barbagallo GM, Olindo G, Corbino L, Albanese V. Analysis of complications in patients treated with the X-Stop Interspinous Process Decompression System: proposal for a novel anatomic scoring system for patient selection and review of the literature. Neurosurgery 2009; 65 (01) 111-119 ; discussion 119–120
- 37 Moojen WA, Arts MP, Jacobs WC. , et al; Leiden The Hague Spine Intervention Prognostic Study Group (SIPS). IPD without bony decompression versus conventional surgical decompression for lumbar spinal stenosis: 2-year results of a double-blind randomized controlled trial. Eur Spine J 2015; 24 (10) 2295-2305
- 38 Strömqvist BH, Berg S, Gerdhem P. , et al. X-stop versus decompressive surgery for lumbar neurogenic intermittent claudication: randomized controlled trial with 2-year follow-up. Spine 2013; 38 (17) 1436-1442
- 39 Lønne G, Johnsen LG, Rossvoll I. , et al. Minimally invasive decompression versus x-stop in lumbar spinal stenosis: a randomized controlled multicenter study. Spine 2015; 40 (02) 77-85
- 40 Siewe J, Selbeck M, Koy T. , et al. Indications and contraindications: interspinous process decompression devices in lumbar spine surgery. J Neurol Surg A 2015; 76 (01) 1-7